Vertiv NetSure 2100 A31-S2 Embedded DC Power System (48V 120A)
Vertiv NetSure 2100 A31-S2 compact embedded DC power system delivering -48V 120A output, designed for 4G/5G telecom access sites and edge network enclosures.

The NetSure 531 A41 is a high-efficiency power system designed for telecommunication facilities and industrial infrastructure.
Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.
Vertiv NetSure 531 A41 Embedded Telecom DC Power System -48V 120A features a modular architecture and high-reliability components for simplified maintenance and monitoring.
Resolves power conversion inefficiency, confined space constraints, and complex battery lifecycle management.
Suitable for telecom base stations, data centers, edge computing aggregation nodes, and industrial DC applications.
| Key specifications | Value |
|---|---|
| AC Input Mode | 380V 3-Phase / 220V 1-Phase Compatible |
| System Output Capacity | 120A (-48VDC) |
| Physical Form Factor | 222 (5U) × 482 × 380 mm |
| Controller Unit | M221S / M830B centralized controller |
| Rectifier Module Slots | 4 Slots |
| DC Distribution Branches | -48VDC (-42V ~ -58V) |
| Overall System Efficiency | Up to 96.2% (Gold Standard) |
| Acoustic Noise | ≤ 55 dBA (at 25°C ambient load) |
| Ingress Protection Rating | IP20 (Indoor Dust & Finger Proof) |
| Dielectric Withstand Voltage | 3000VAC Input to Ground (< 5mA) |
Vertiv

Vertiv NetSure 2100 A31-S2 compact embedded DC power system delivering -48V 120A output, designed for 4G/5G telecom access sites and edge network enclosures.

The NetSure 2100-A31-S3 is a high-reliability, high-power-density 1U minimalist embedded telecom DC power system engineered by Vertiv for space-constrained edge computing nodes and indoor access networks.

Genuine Vertiv NetSure 531 A31-S1 3U embedded DC power system offering 120A continuous power and full front-access maintenance for telecom rooms.

The NetSure 531A31-S1 is a highly reliable 3U compact embedded DC power system by Vertiv, supporting 150A to 200A system capacity and fully compatible with high-efficiency R48-2000e3 rectifier modules, engineered for rigorous telecom rooms and edge data centers.
Comprehensive engineering guide to the Vertiv NetSure 531 A41 embedded telecom DC power system (-48V 120A): electrical topology, eSure rectifier compatibility, brownfield retrofits, and authenticity verification.
An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.