Vertiv NetSure 2100 A31-S2 Embedded DC Power System (48V 120A)
Vertiv NetSure 2100 A31-S2 compact embedded DC power system delivering -48V 120A output, designed for 4G/5G telecom access sites and edge network enclosures.

The Vertiv NetSure 531 A31-S1 is a field-proven 3U 19-inch rack-mount embedded DC power system delivering up to 120A at -48VDC across 3 rectifier slots, featuring full front-access cabling, smart battery protection, and an advanced M221S controller.
Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.
Standard 19-inch 3U embedded telecom DC power subrack.
Provides dependable, high-density DC power aggregation and easy front maintenance within cellular base station cabinets.
Cellular macro base stations, enterprise network centers, and optical access nodes.
| Key specifications | Value |
|---|---|
| System Output Capacity | 120 A |
| Nominal Output Voltage | -48VDC (-42V ~ -58V) VDC |
| Output Voltage Range | -48VDC (-42V ~ -58V) VDC |
| AC Input Voltage | 85 ~ 300 VAC |
| Rectifier Module Slots | 3 Slots |
| System Monitoring Controller | M221S / M222S LCD centralized monitoring unit |
| Power Conversion Efficiency | 95.8% |
| Ingress Protection (IP Rating) | IP20 |
| Physical Dimensions | 132 × 482 × 330 mm (3U 19-inch) |
| Operating Temperature Range | -40°C to +70°C |
Vertiv

Vertiv NetSure 2100 A31-S2 compact embedded DC power system delivering -48V 120A output, designed for 4G/5G telecom access sites and edge network enclosures.

The NetSure 2100-A31-S3 is a high-reliability, high-power-density 1U minimalist embedded telecom DC power system engineered by Vertiv for space-constrained edge computing nodes and indoor access networks.

The NetSure 531 A41 is a high-efficiency power system designed for telecommunication facilities and industrial infrastructure.

The NetSure 531A31-S1 is a highly reliable 3U compact embedded DC power system by Vertiv, supporting 150A to 200A system capacity and fully compatible with high-efficiency R48-2000e3 rectifier modules, engineered for rigorous telecom rooms and edge data centers.
An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.