Huawei / Indoor Telecom Power Systems

AIU03-100C Equipment information & support

The Huawei AIU03-100C (Part Number: 02312MUD) is a carrier-grade AC Input Unit power distribution module engineered for high-capacity telecom DC power systems (such as TP482000B and ETP48400), featuring heavy-duty busbar blind-mate connectors and comprehensive input protection.

Equipment information

Brand
Huawei
Equipment model
AIU03-100C
Equipment type
Indoor Telecom Power Systems
Controller / software version
Confirm against the installed equipment
View full product specifications
Huawei AIU03-100C AC Input Unit Power Module (200-240V/346-415V 100A Busbar Blind-Mate) - Nameplate & Electrical Specifications

Information below comes from the current product catalogue. Confirm the controller, software version and configuration of the installed equipment separately.

Rated Operational Voltage
200-240V / 346-415V AC
Maximum Rated Input Current
80A / 100A Max
AC Power Input System
380V 3-Phase / 220V 1-Phase Compatible
Connection & Busbar Interface
High-Current Blind-Mate Gold-Plated Busbar
System & Cabinet Compatibility
Huawei TP482000B / ETP48400 Series
Overall System Efficiency
Up to 96.2% (Gold Standard)

Alarms & troubleshooting

CAN_BUS_OFF / NODE_TIMEOUT (Controller CAN Bus Interface Lost / Node Timeout)
Controller front panel red ALARM LED steady ON; display flags bus communication offline; rectifiers operate autonomously.
Subrack communication ribbon cable disconnected, high EMI interference on CAN lines, transceiver IC fault, or open termination resistor.
1. Reseat controller module and reconnect subrack ribbon cables; 2. Measure DC voltage on CAN_H and CAN_L (nominal ~2.5V differential); 3. Ensure communication cabling is isolated from high-power AC cables; 4. Reboot controller unit to perform bus re-initialization; 5. If communication remains offline, replace controller unit.

Access Complete Maintenance & Full Alarm Troubleshooting Manual

This page lists high-frequency critical alarm codes commonly encountered in field maintenance. Comprehensive manufacturer troubleshooting matrices, board-level repair guides, detailed electrical schematics, and firmware commissioning manuals are delivered alongside equipment upon formal project procurement, accompanied by dedicated FAE technical support.

Share on-site information

  1. 01

    Identify the exact model

    Record the nameplate, system model and controller or module model.

  2. 02

    Keep the alarm details

    Record the full alarm text, indicator colour, timing and whether it persists.

  3. 03

    Describe recent changes

    Note recent replacements, software updates or configuration changes.

Record information visible in the existing interface. Electrical measurements, disassembly and replacement should follow the applicable manufacturer's manual and be performed by qualified personnel.

Your model and these details will be added to the enquiry form for you to review before sending.

Related technical articles

Browse the technical guides or send a question about this model.

View all articles

Need a replacement module or supporting equipment?

Confirm the full model, system configuration and compatibility requirements before enquiring about suitable products.

Ask about suitable products

Have a model and an on-site issue?

Share the exact model, alarm text and observed symptoms to help identify relevant information and compatibility requirements.

Request technical support