DPC DZY-48/50H III Telecom Rectifier Module Equipment information & support
The DPC DZY-48/50H III is an industrial-grade 2900W -48V/50A switch-mode telecom rectifier module designed for BTS and DC plant cabinets. Utilizing full digital DSP control and soft-switching topology, it converts 85V~300V AC utility power into stabilized -48V DC, supporting hot-swap insertion and active autonomous current sharing.
Equipment information
- Brand
- Dpc
- Equipment model
- DPC DZY-48/50H III Telecom Rectifier Module
- Equipment type
- DC power systems
- Controller / software version
- Confirm against the installed equipment

Information below comes from the current product catalogue. Confirm the controller, software version and configuration of the installed equipment separately.
- Rated Output Power
- 2900W industrial telecom-grade rated output power
- Nominal DC Output Voltage
- -48V DC (float/equalize charge range -42V to -58V DC)
- Rated Output Current
- 50A continuous stable high-current supply
- Power Conversion Efficiency
- ≥ 95.5% digital high-frequency soft-switching conversion efficiency
- AC Input Voltage Range
- 85V AC to 300V AC (ultra-wide single-phase AC adaptive)
- Hot-Swap Capability
- Fully digital intelligent hot-swappable design with autonomous current sharing control
Alarms & troubleshooting
Access Complete Maintenance & Full Alarm Troubleshooting Manual
This page lists high-frequency critical alarm codes commonly encountered in field maintenance. Comprehensive manufacturer troubleshooting matrices, board-level repair guides, detailed electrical schematics, and firmware commissioning manuals are delivered alongside equipment upon formal project procurement, accompanied by dedicated FAE technical support.
Share on-site information
- 01
Identify the exact model
Record the nameplate, system model and controller or module model.
- 02
Keep the alarm details
Record the full alarm text, indicator colour, timing and whether it persists.
- 03
Describe recent changes
Note recent replacements, software updates or configuration changes.
Record information visible in the existing interface. Electrical measurements, disassembly and replacement should follow the applicable manufacturer's manual and be performed by qualified personnel.
Related technical articles
Browse the technical guides or send a question about this model.
View all articlesNeed a replacement module or supporting equipment?
Confirm the full model, system configuration and compatibility requirements before enquiring about suitable products.
Have a model and an on-site issue?
Share the exact model, alarm text and observed symptoms to help identify relevant information and compatibility requirements.