Vertiv BMK1115601-006 Subrack Telecom DC Power System (-48V 200A 3U)
Standard 19-inch rack-mount embedded DC power system engineered for wide-range AC input, active rectifier redundancy, and tiered load/battery low-voltage disconnect.

The Vertiv NetSure 731 A98 is a 2.1m high-capacity outdoor telecom DC power cabinet system delivering -48V/600A rated output with IP55 protection, engineered for mission-critical macro stations and extreme environmental installations.
Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.
The Vertiv NetSure 731 A98 is a 2.1m high-capacity outdoor telecom DC power cabinet system delivering -48V/600A rated output with IP55 protection, engineered for mission-critical macro stations and extreme environmental installations.
The Vertiv NetSure 731 A98 2.1m outdoor telecom power cabinet system is an integrated industrial platform built for superior durability. Utilizing a dual-compartment insulated architecture, it strictly isolates equipment and battery sections. The cabinet door integrates a high-efficiency heat exchanger and independent emergency ventilation ducting to ensure precise internal thermal regulation while completely blocking ingress of dust and moisture. Accommodating up to 12 hot-swappable R48-2900U or R48-3200e rectifier modules, the system guarantees a sustained 600A DC output. Managed by the M830B controller with dual-stage LVD protection, it delivers continuous, rock-solid power across extreme environments.
The Vertiv NetSure 731 A98 is a 2.1m high-capacity outdoor telecom DC power cabinet system delivering -48V/600A rated output with IP55 protection, engineered for mission-critical macro stations and extreme environmental installations.
| Key specifications | Value |
|---|---|
| System output capacity | 600A (-48V DC) Continuous Stable Power Supply Capacity |
| Cabinet Structure Spec | 2.1m Dual-Door Compartmentalized Outdoor Cabinet (IP55 Rated) |
| Cabinet Cooling Method | Door-Mounted Heat Exchanger + Dedicated Emergency Ventilation Duct |
| DC Distribution Branches | -48VDC (-42V ~ -58V) |
| Battery Energy Storage Configuration | Thermally Isolated Battery Bay Supporting 4 Strings of 100Ah~150Ah Batteries |
| Operating Temperature Range | -40°C ~ +50°C Wide Operating Temperature Range |
| Rectifier Module Slots | 12 Slots |
| System Monitoring Controller | M830B Advanced Integrated Supervisory Unit |
Vertiv

Standard 19-inch rack-mount embedded DC power system engineered for wide-range AC input, active rectifier redundancy, and tiered load/battery low-voltage disconnect.

Featuring full-bridge resonant soft-switching technology and digital DSP-driven control, the ER22005S achieves a peak conversion efficiency of ≥ 94.0%. With its advanced hybrid natural convection and thermal fan cooling, autonomous active current sharing, and hot-pluggable architecture, the unit ensures stable, transient-free high-voltage DC output under severe electromagnetic interference and harsh ambient temperatures.

The Vertiv ER22010-T is a 220Vdc/10A high-voltage DC switch-mode rectifier module engineered for utility substations, power plants, and HVDC distribution systems. Utilizing advanced resonant soft-switching technology, it delivers >94% peak efficiency, hot-swappable reliability, and comprehensive electrical protection.

The Vertiv ER22020-T is a 4.4kW high-power switch-mode rectifier module delivering 220Vdc/20A for utility substations and critical industrial DC systems. Powered by full DSP digital control and LLC resonant conversion, it provides industry-leading electrical stability across extreme temperatures.
An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.