Vertiv NetSure 731 A91-S2 Official White Background Photo View 1
VertivModel: NetSure 731 A91-S2

Vertiv NetSure 731 A91-S2 Subrack Telecom DC Power System (-48V 300A 4U)

The Vertiv NetSure 731 A91-S2 is a high-density 19-inch 6U embedded telecom DC power system delivering up to 300A output, engineered for 4G/5G wireless sites, central offices, and edge computing nodes.

Instant Engineer & Sales Quotation

Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.

WhatsApp

Clear support from selection to delivery

360°Technical support
N+Service commitment
3Steps shipping
100%Customer satisfaction
Nominal Output Voltage
-48VDC (-42V ~ -58V) VDC
AC Input Voltage
85VAC ~ 300VAC (Nominal 220VAC) VAC
Rated DC Output Current
300A (System Capacity 14.4kW)
Peak Energy Efficiency
≥96.0%
Managed Rectifier Capacity
4 Slots for R48-2900U Modules
Smart Monitoring Controller
M830B / NCU Controller

What this product is

What this product is

An integrated -48VDC power system comprising a rectifier subrack, AC/DC distribution assembly, dual Low Voltage Disconnect contactors, and an advanced M830B/NCU controller. It houses up to six high-efficiency rectifiers to convert fluctuating AC mains into clean, regulated DC power.

What problem it solves

Eliminates site footprint constraints in tight telecom shelters, mitigates grid instability across 85-300VAC, and prevents catastrophic battery degradation through precision multi-stage low-voltage disconnection.

Who and where it is for

5G outdoor base station enclosures, telecom aggregation nodes, edge computing rooms, enterprise core routing facilities, and industrial automation networks demanding robust -48V backup.

Core advantages

  • Peak energy efficiency of ≥96.0%, drastically lowering heat dissipation and site operating costs
  • Ultra-wide input window (85VAC to 300VAC) guaranteeing operational resilience in poor grid regions
  • Dual-stage LVD architecture (LLVD for shedding non-critical loads, BLVD for absolute battery discharge protection)
  • Fully hot-swappable architecture across all rectifiers and control units for zero-downtime maintenance
  • Comprehensive battery care algorithms including precision thermal compensation, automated boost/float management, and scheduled SOC testing

Technical specifications

Key specificationsValue
AC Input Voltage85VAC ~ 300VAC (Nominal 220VAC) VAC
Smart Monitoring ControllerM830B / NCU Controller
Cooling System ArchitectureIntelligent temperature-controlled cooling
Nominal Output Voltage-48VDC (-42V ~ -58V) VDC
Rated DC Output Current300A (System Capacity 14.4kW)
Managed Rectifier Capacity4 Slots for R48-2900U Modules
Form Factor Dimensions (HxWxD)177 (4U) × 482 × 360 mm
Peak Energy Efficiency≥96.0%
Operating Temperature Range-40°C ~ +65°C

Applications

01

4G/5G macro and micro base transceiver stations (BTS)

02

FTTx optical line terminal (OLT) shelters and broadband aggregation sites

03

Railway signaling, SCADA, and wayside communication power supplies

04

Substation protection systems and enterprise data room DC distribution

Frequently asked questions

Continue exploring

Vertiv

Vertiv ER22005S Genuine Telecom Hardware Shot 1
VertivModel: ER22005S

Vertiv ER22005S Utility Substation High-Voltage DC Operating Power Rectifier (220V 5A 1100W)

Featuring full-bridge resonant soft-switching technology and digital DSP-driven control, the ER22005S achieves a peak conversion efficiency of ≥ 94.0%. With its advanced hybrid natural convection and thermal fan cooling, autonomous active current sharing, and hot-pluggable architecture, the unit ensures stable, transient-free high-voltage DC output under severe electromagnetic interference and harsh ambient temperatures.

View details

Technical and buying guides

Vertiv NetSure 531 A41 Subrack DC Power System Wiring, LLVD Configuration, and Commissioning Guide

An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.