Vertiv BMK1115601-006 Subrack Telecom DC Power System (-48V 200A 3U)
Standard 19-inch rack-mount embedded DC power system engineered for wide-range AC input, active rectifier redundancy, and tiered load/battery low-voltage disconnect.

The Vertiv NetSure 731 A91-S1 is an 11U rack-mount -48VDC high-density switch-mode telecom power system delivering output capacity up to 600A.
Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.
The NetSure 731 A91-S1 is an enterprise- and carrier-grade embedded DC power solution engineered by Vertiv for telecom central offices, core access nodes, and edge computing facilities. It combines three-phase/single-phase AC input terminals, high-efficiency rectifiers, intelligent controller hardware, and comprehensive DC PDU infrastructure featuring LLVD and BLVD contactors.
It resolves escalating payload power demands within space-constrained 19-inch cabinets, lowers parasitic thermal load and energy expenditure via high-efficiency conversion, and prevents catastrophic battery deep-discharge events through multi-tier automated disconnect routines.
4G/5G macro cell hub sites, optical transport nodes (OTN), Central Offices (CO), metro aggregation points, enterprise data centers running native -48VDC equipment, and railway dispatch centers.
| Key specifications | Value |
|---|---|
| Smart Monitoring Controller | M830B / NCU Advanced Controller Unit |
| AC Input Voltage | 85VAC ~ 300VAC (Nominal 220V/380VAC) VAC |
| Cooling System Architecture | Temperature-controlled Forced Air Cooling |
| Nominal Output Voltage | -48VDC (-42V ~ -58V) VDC |
| Managed Rectifier Capacity | 6 × R48-2900U / R48-3200e Modules |
| Rated DC Output Current | 600A (Max Capacity 28.8kW) |
| Peak Energy Efficiency | ≥96.0% |
| Form Factor Dimensions (HxWxD) | 177 (4U) × 482 × 360 mm |
| Operating Temperature Range | -40°C ~ +65°C |
Vertiv

Standard 19-inch rack-mount embedded DC power system engineered for wide-range AC input, active rectifier redundancy, and tiered load/battery low-voltage disconnect.

Featuring full-bridge resonant soft-switching technology and digital DSP-driven control, the ER22005S achieves a peak conversion efficiency of ≥ 94.0%. With its advanced hybrid natural convection and thermal fan cooling, autonomous active current sharing, and hot-pluggable architecture, the unit ensures stable, transient-free high-voltage DC output under severe electromagnetic interference and harsh ambient temperatures.

The Vertiv ER22010-T is a 220Vdc/10A high-voltage DC switch-mode rectifier module engineered for utility substations, power plants, and HVDC distribution systems. Utilizing advanced resonant soft-switching technology, it delivers >94% peak efficiency, hot-swappable reliability, and comprehensive electrical protection.

The Vertiv ER22020-T is a 4.4kW high-power switch-mode rectifier module delivering 220Vdc/20A for utility substations and critical industrial DC systems. Powered by full DSP digital control and LLC resonant conversion, it provides industry-leading electrical stability across extreme temperatures.
An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.