Nominal Output Voltage
-48VDC (-42V ~ -58V) VDC
AC Input Voltage
85VAC ~ 300VAC (Nominal 220V/380VAC) VAC
Rated DC Output Current
600A (Max Capacity 28.8kW)
Peak Energy Efficiency
≥96.0%
Managed Rectifier Capacity
6 × R48-2900U / R48-3200e Modules
Smart Monitoring Controller
M830B / NCU Advanced Controller Unit

What this product is

What this product is

The NetSure 731 A91-S1 is an enterprise- and carrier-grade embedded DC power solution engineered by Vertiv for telecom central offices, core access nodes, and edge computing facilities. It combines three-phase/single-phase AC input terminals, high-efficiency rectifiers, intelligent controller hardware, and comprehensive DC PDU infrastructure featuring LLVD and BLVD contactors.

What problem it solves

It resolves escalating payload power demands within space-constrained 19-inch cabinets, lowers parasitic thermal load and energy expenditure via high-efficiency conversion, and prevents catastrophic battery deep-discharge events through multi-tier automated disconnect routines.

Who and where it is for

4G/5G macro cell hub sites, optical transport nodes (OTN), Central Offices (CO), metro aggregation points, enterprise data centers running native -48VDC equipment, and railway dispatch centers.

Core advantages

  • Ultra-high power density 4U compact design delivering up to 600A (28.8kW) to overcome space constraints in crowded telecom sites.
  • Exceptional peak conversion efficiency of ≥96.0%, significantly reducing rectifier losses and thermal loads for greener operations.
  • Wide AC input voltage range (85VAC to 300VAC) ensuring uninterrupted, stable power output under unstable grid conditions.
  • Integrated dual LLVD and BLVD protection mechanisms to shed non-critical loads sequentially and prevent deep battery discharge.

Technical specifications

Key specificationsValue
Smart Monitoring ControllerM830B / NCU Advanced Controller Unit
AC Input Voltage85VAC ~ 300VAC (Nominal 220V/380VAC) VAC
Cooling System ArchitectureTemperature-controlled Forced Air Cooling
Nominal Output Voltage-48VDC (-42V ~ -58V) VDC
Managed Rectifier Capacity6 × R48-2900U / R48-3200e Modules
Rated DC Output Current600A (Max Capacity 28.8kW)
Peak Energy Efficiency≥96.0%
Form Factor Dimensions (HxWxD)177 (4U) × 482 × 360 mm
Operating Temperature Range-40°C ~ +65°C

Applications

01

Telecom 4G/5G macro cellular base stations and distributed remote power sites

02

Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups

03

Utility power grid dispatch centers and high-voltage substation DC switchgear rooms

04

Railway transit signaling, automated train control, and communications equipment rooms

Frequently asked questions

Continue exploring

Vertiv

Vertiv ER22005S Genuine Telecom Hardware Shot 1
VertivModel: ER22005S

Vertiv ER22005S Utility Substation High-Voltage DC Operating Power Rectifier (220V 5A 1100W)

Featuring full-bridge resonant soft-switching technology and digital DSP-driven control, the ER22005S achieves a peak conversion efficiency of ≥ 94.0%. With its advanced hybrid natural convection and thermal fan cooling, autonomous active current sharing, and hot-pluggable architecture, the unit ensures stable, transient-free high-voltage DC output under severe electromagnetic interference and harsh ambient temperatures.

View details

Technical and buying guides

Vertiv NetSure 531 A41 Subrack DC Power System Wiring, LLVD Configuration, and Commissioning Guide

An authoritative engineering manual for the Vertiv / Emerson NetSure 531 A41 series 19-inch 4U telecom embedded DC power subrack. Covers AC/DC distribution terminal schematics, battery and load cabling, M830B / M221S supervisory parameter setup, two-stage LLVD (Load Low Voltage Disconnect) and BLVD (Battery Low Voltage Disconnect) threshold programming, and full on-site commissioning procedures.