Delta ESR-48/56AC High-Efficiency Switch-Mode Telecom Rectifier Module (-48V 56A 3000W) - Official Front View
DeltaModel: ESR-48/56AC

Delta ESR-48/56AC High-Efficiency Switch-Mode Telecom Rectifier Module (-48V 56A 3000W)

The Delta ESR-48/56AC is a carrier-grade high-frequency switch-mode telecom rectifier module delivering nominal -48V DC, 56A maximum output current, and 3000W rated power across a wide AC input voltage range.

Pricing is confirmed by project configuration and quantity

Request a quote
Nominal Output Voltage
-48V DC (Adjustable: -42V to -58V)
Rated Output Current
56A
Rated Output Power
3000W
AC Input Voltage Range
88V to 300V AC (Nominal 220V/230V)
Operating Temperature Range
-25°C to +65°C
Cooling & Form Factor
Smart Fan Forced Air / Subrack Hot-Swap

What this product is

What this product is

This module slots into Delta telecom DC power subracks, converting incoming single-phase utility or generator AC power into low-ripple -48V DC power to drive base station equipment and charge backup batteries.

What problem it solves

Eliminates low power conversion efficiency, high input harmonic distortion, and nuisance tripping during utility voltage sags, ensuring high power factor and grid tolerance.

Who and where it is for

Engineered for wireless macro cell sites, microwave transmission hubs, core switching offices, and industrial power distribution systems utilizing Delta subracks.

Core advantages

  • High-Efficiency Power Conversion: Typical efficiency exceeds 92%, substantially reducing site utility costs and cooling requirements.
  • Ultra-Wide AC Input Range: Operates reliably across 88V to 300V AC, withstanding severe grid voltage drops in remote regions.
  • Hitless Hot-Plug Maintenance: Supports live insertion and removal without interrupting continuous -48V DC bus power delivery.
  • Active Digital Current Sharing: Autonomous load sharing across multiple parallel modules ensures uninterrupted N+1 redundancy.

Technical specifications

Key specificationsValue
Nominal Output Voltage-48V DC (Adjustable: -42V to -58V)
Rated Output Current56A
Rated Output Power3000W
AC Input Voltage Range88V to 300V AC (Nominal 220V/230V)
Operating Temperature Range-25°C to +65°C
Cooling & Form FactorSmart Fan Forced Air / Subrack Hot-Swap

Applications

01

4G/5G Telecom Cell Sites & Distributed Power Systems

02

Carrier Core Network Facilities & IDC DC Plants

03

Industrial Automation & Utility Substation DC UPS

Frequently asked questions