Vertiv / DC power systems

R48-1000E3 Equipment information & support

The Vertiv R48-1000E3 is an ultra-compact, high-efficiency telecom switch-mode rectifier module delivering a nominal -48V DC output (-42V to -58V DC adjustable), 20A maximum continuous current, and 1000W rated capacity. It converts standard single-phase AC utility or high-voltage DC power into high-integrity telecom-grade DC power to energize telecommunication loads and maintain connected backup battery banks.

Equipment information

Brand
Vertiv
Equipment model
R48-1000E3
Equipment type
DC power systems
Controller / software version
Confirm against the installed equipment
View full product specifications
Vertiv R48-1000E3 Pure White Background Hardware Shot 1

Information below comes from the current product catalogue. Confirm the controller, software version and configuration of the installed equipment separately.

Rated Output Voltage
-48V DC (-42V ~ -58V DC)
Maximum Output Current
20A
Rated Output Power
1000W
AC Input Voltage Range
85V AC ~ 300V AC
Peak Conversion Efficiency
≥ 95.5%
Operating Temperature Range
-40°C to +75°C

Alarms & troubleshooting

No public alarm guide is available for this model yet

Share the original alarm text and controller version to help identify applicable documentation. Alarm definitions and procedures may vary by version.

Share on-site information

Share on-site information

  1. 01

    Identify the exact model

    Record the nameplate, system model and controller or module model.

  2. 02

    Keep the alarm details

    Record the full alarm text, indicator colour, timing and whether it persists.

  3. 03

    Describe recent changes

    Note recent replacements, software updates or configuration changes.

Record information visible in the existing interface. Electrical measurements, disassembly and replacement should follow the applicable manufacturer's manual and be performed by qualified personnel.

Your model and these details will be added to the enquiry form for you to review before sending.

Related technical articles

Browse the technical guides or send a question about this model.

View all articles

Need a replacement module or supporting equipment?

Confirm the full model, system configuration and compatibility requirements before enquiring about suitable products.

Ask about suitable products

Have a model and an on-site issue?

Share the exact model, alarm text and observed symptoms to help identify relevant information and compatibility requirements.

Request technical support