Vertiv Liebert GXE2 pure white studio product shot
VertivModel: Liebert GXE2

Vertiv Liebert GXE2 UPS 6-20kVA

Vertiv Liebert GXE2 is an industrial-grade, high-reliability solution engineered for mission-critical telecom sites, data centers, and power applications.

Instant Engineer & Sales Quotation

Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.

WhatsApp

Clear support from selection to delivery

360°Technical support
N+Service commitment
3Steps shipping
100%Customer satisfaction
Rated output power
额定输出功率: 5.4 / 9 / 13.5 / 18 kW
Input voltage range
交流输入电压: 相电压:220 / 230 / 240;线电压:380 / 400 / 415 Vac
Output voltage
标称直流输出电压: 单相:220 / 230 / 240;三相:380 / 400 / 415 Vac
Mains to Battery Transfer Time
Mains to Battery Transfer Time: 0 ms
Parallel Capacity and Redundancy
Parallel Capacity and Redundancy: N + X,1 ≤ N + X ≤ 3,X = 0或1;最高2 + 1冗余 台
UPS Topology
UPS Topology: 在线式高频双变换,正弦波输出,全数字控制

What this product is

What this product is

Vertiv Liebert GXE2 incorporates carrier-grade components and a high-density modular architecture to ensure exceptional uptime and low operational costs.

What problem it solves

Eliminates downtime risks associated with severe grid fluctuations, harsh ambient temperatures, dense thermal loads, and single-point system failures.

Who and where it is for

Telecom base stations, hyperscale data centers, enterprise server rooms, edge computing nodes, and harsh industrial automation setups.

Core advantages

  • Industry-leading energy conversion efficiency minimizing long-term OPEX and site PUE.
  • Ultra-wide input voltage and temperature operating envelope designed for extreme grid conditions.
  • Live hot-swappable modularity enabling seamless tool-less field maintenance with zero service downtime.
  • Intelligent telemetry and monitoring telemetry compatible with open industry management protocols.

Technical specifications

Key specificationsValue
Rated output power额定输出功率: 5.4 / 9 / 13.5 / 18 kW
Electrical Safety Protection电气安全防护等级: IP20
Default charging currentCharge Current: ≤5 / ≤2 / ≤8 / ≤4 / ≤13 A
Mains mode efficiencyMains Mode Efficiency: 最高95 / 最高95.5 %
Operating Temperature Range工作环境温度范围: 0~50 ℃
ECO mode efficiencyECO Mode Efficiency: 最高99 %
Input power factorInput Power Factor: ≥0.99
Input frequency rangeInput Frequency Range: 40~70 Hz
Front and rear installation clearanceInstallation Ventilation Clearance: 前后最小200;后方示意间距500 mm
Output voltage标称直流输出电压: 单相:220 / 230 / 240;三相:380 / 400 / 415 Vac
UPS TopologyUPS Topology: 在线式高频双变换,正弦波输出,全数字控制
Earth leakage currentEarth Leakage Current: 3.5~100 mA
Input voltage range交流输入电压: 相电压:220 / 230 / 240;线电压:380 / 400 / 415 Vac
relative humidityRelative Humidity: 5~95 %RH
Parallel Capacity and RedundancyParallel Capacity and Redundancy: N + X,1 ≤ N + X ≤ 3,X = 0或1;最高2 + 1冗余 台
Dimensions物理结构外形尺寸: 160 × 400 × 350;160 × 500 × 420;160 × 530 × 420 mm
Rated battery voltageRated Battery Voltage: 192~240 Vdc
Display languagesDisplay Languages: 中文、英文
Rated input frequencyRated Input Frequency: 50 / 60 Hz
Installation methodInstallation Method: 建议落地安装,安装于混凝土或其他不燃表面
ECO Mode Applicable ConfigurationECO Mode Applicable Configuration: 单机且配置外部电池;旁路正常时由旁路供电,旁路异常时由逆变器供电
Operating altitudeOperating Altitude: ≤2000 m
ECO Voltage RangeECO Voltage Range: ±5 / ±10 / ±15;默认±10 %
Communication interfaceCommunication Interfaces: 智能卡接口、干接点、RS232、RS485
ECO Frequency RangeECO Frequency Range: ±1 / ±2 / ±3;默认±3 Hz
Battery cold startBattery Cold Start: 支持
Modbus address rangeModbus Address Range: 1~128;默认1
Shared Battery Full-Load RuntimeShared Battery Full-Load Runtime: 2~3 min
Dynamic Response Recovery TimeDynamic Response Recovery Time: 60 / 40 ms
Dry contact port countDry Contact Port Quantity: 3个端口,共6针;标识REPO、1、2
Control functionsControl Functions: 开机、关机、转旁路、告警静音、手动电池测试、故障清除、定时开关机
Recommended Minimum Battery ModulesRecommended Minimum Battery Modules: 10 kVA:至少2组;20 kVA:至少4组
Bypass Voltage Upper LimitBypass Voltage Upper Limit: +10 / +15 / +20;默认+20 %
Bypass Voltage Lower LimitBypass Voltage Lower Limit: -10 / -20 / -30 / -40;默认-40 %
Bypass Frequency RangeBypass Frequency Range: ±5 / ±10;默认±10 Hz
Battery String QuantityBattery String Quantity: 16 / 18 / 20;默认16 块
Battery Backup TimeBattery Backup Time: 6.0 / 7.5 / 9.0 / 11.0 / 14.5 / 19.5 / 29.0 / 48.0 / 100.0 min
Battery Equalize ChargeBattery Equalize Charge: 可启用或禁用;默认禁用
Battery Capacity Setting RangeBattery Capacity Setting Range: 7~3000 Ah
Battery Module ExpansionBattery Module Expansion: 建议扩展6个电池模块;15 / 20 kVA每次至少增加2个模块
Battery TypeBattery Type: 密封免维护铅酸电池,12 V / 9 Ah
Battery Auto-Test IntervalBattery Auto-Test Interval: 禁用 / 8 / 12 / 16 / 20 / 26;默认禁用 周
Output Voltage THDOutput Voltage THD: <2 %
Output Voltage SettingOutput Voltage Setting: 220 / 230 / 240;默认220 V
Output Current Crest FactorOutput Current Crest Factor: 3:1
Output Overload CapacityOutput Overload Capacity: 105%~125%:10 min;125%~150%:1 min;150%:200 ms
Output Frequency Sync RangeOutput Frequency Sync Range: 额定频率±3;可设置±0.5~±5 Hz
Output Frequency SettingOutput Frequency Setting: 自动频率且允许旁路;自动频率且禁止旁路;50 Hz且禁止旁路;60 Hz且禁止旁路
Output Frequency Slew RateOutput Frequency Slew Rate: 默认0.5;可设置0.2 / 0.5 / 1 Hz/s
Main and Bypass Backfeed ProtectionMain and Bypass Backfeed Protection: 具备
Low Battery Warning TimeLow Battery Warning Time: 2~30;默认2 min
Protection and Alarm MonitoringProtection and Alarm Monitoring: 输出短路、旁路反灌、输入中性线缺失、输入异常、整流器过载、逆变器过载、旁路过流、系统过温、风扇故障;电池反接、低电量、电压异常、缺失、测试失败、过温及放电终止关机;内部通信及整流器、DC/DC、直流母线、充电器、辅助电源、逆变器故障;关机状态输出带电、逆变继电器粘连、中性线对地异常;并机通信、电缆、台数、过载、冗余丢失、均流及设置不一致监测;REPO及关机输入监测
Noise LevelNoise Level: <55 / <58 dB
Storage TemperatureStorage Temperature: -40~+70 ℃
Conditional Short-Circuit Current RatingConditional Short-Circuit Current Rating: 10 kA
Battery Discharge Protection TimeBattery Discharge Protection Time: 1~4320;默认4320 min
Battery Over-Temperature Alarm ThresholdBattery Over-Temperature Alarm Threshold: 40~60;默认50 ℃
Battery Ambient TemperatureBattery Ambient Temperature: 15~25;标准工作温度20 ℃
Emergency Power Off FunctionEmergency Power Off Function: REPO立即关闭整流器、逆变器、逆变及旁路输出、充电与放电
Expected Fan LifeExpected Fan Life: 20000~40000 h
DisplayDisplay: 彩色LCD,320 × 240点阵;支持输入、输出、负载、电池、告警及历史记录显示
Energy Saving ModesEnergy Saving Modes: ECO供电模式、智能休眠模式
Operating ModesOperating Modes: 正常、旁路、电池、ECO、故障、维护旁路
LBS Role SettingLBS Role Setting: 禁用、主机、从机;默认禁用
RDU-SIC Network ManagementRDU-SIC Network Management: IRM / 1-Wire温度、温湿度及干接点传感器接入;告警记录、Trap、电子邮件、短信;Web、SNMP NMS、TCP/IP RDU-Manager、Nform Velocity Server监控及Network Shutdown集成
REPO Interface SupplyREPO Interface Supply: 5 Vdc / 100 mA
SIC Network ManagementSIC Network Management: TCP/IP及Internet远程监控、计算机安全关机;扩展网络接口最多级联8个温湿度传感器
UNITY-DP Communication ProtocolsUNITY-DP Communication Protocols: Web、SNMP、Modbus、BACnet、YDN23
AC Distribution CompatibilityAC Distribution Compatibility: 三相五线A / B / C / N / PE;TN、TT、IT系统
Dual Bus SynchronizationDual Bus Synchronization: 支持LBS;两套独立单机或并机系统组成主从系统;正常和/或旁路运行
Rear Panel PortsRear Panel Ports: Intellislot、REPO、干接点、多功能接口、RS232、交流输入、电池输入、交流输出;部分面板另有并机接口
Auto Restart on Mains RecoveryAuto Restart on Mains Recovery: 可启用或禁用;默认启用
Dry Contact RatingDry Contact Rating: 125 Vdc / 0.5 A;30 Vdc / 1 A
Dry Contact Input FunctionsDry Contact Input Functions: 电池模式关机、任意模式关机、维护模式;默认维护模式
Dry Contact Output FunctionsDry Contact Output Functions: 低电池、使用电池、使用旁路、UPS故障
Parallel Compatibility ConditionsParallel Compatibility Conditions: 同容量、同市电电源、公共输出母线、相同参数设置
Parallel FunctionParallel Function: 环形通信冗余;正常与旁路无缝切换;过载消除后自动返回;各机LCD可查询系统总负载
Parallel Communication Cable QuantityParallel Communication Cable Quantity: 1 + 1系统:2根;2 + 1系统:3根
Recommended Battery Cable LengthRecommended Battery Cable Length: ≤3 m
Control Interface and ProtocolControl Interface and Protocol: 标准RJ45;Modbus / Jbus,或Vertiv温度、温湿度传感器
Smart Card CompatibilitySmart Card Compatibility: SIC、RDU-SIC、RS485、UNITY-DP
Battery Sharing CapabilityBattery Sharing Capability: 15 / 20 kVA可共享电池串或使用独立电池串;6 / 10 kVA仅可使用独立电池串
Power Terminal ConfigurationPower Terminal Configuration: 输入L / N / PE;输出L / N / PE;电池BAT+ / BAT- / PE
Auto Restart DelayAuto Restart Delay: 0~999;默认10 s
Input/Output Phase ConfigurationInput/Output Phase Configuration: 单进单出或三进单出
Cooling MethodCooling Method: 内置风扇强制风冷,前进风、后出风
Net WeightNet Weight: 10.9 / 16.10 / 23.5 kg
Mains to Battery Transfer TimeMains to Battery Transfer Time: 0 ms
Inverter to Bypass Transfer TimeInverter to Bypass Transfer Time: ≤0 ms

Applications

01

Telecom cellular base stations and central offices -48V DC backup battery strings

02

Data center high-rate UPS battery banks delivering critical runtime for server loads

03

Electric utility substations 110V/220V DC switchgear breaker trip and closing power

04

Off-grid renewable solar/wind hybrid storage and industrial uninterruptible backup sites

Frequently asked questions

Continue exploring

Vertiv