| Safety standard | IEC/EN 62040-1:2008 + A1:2013 |
| Operating Input Voltage Range | 120~288 Vac; 100% load; operation across the full input voltage range |
| Transfer Time & Dynamic Response | 0 ms |
| Apparent Power | 1000 VA |
| Active Power | 800 W |
| Operating Temperature Range | 0~+40 °C |
| Battery charging time | 6 h |
| Input power factor | 0.8 |
| Rated input voltage | 220 Vac |
| Input power factor | 0.99 |
| Input frequency range | 45~65 Hz; adaptive |
| Output voltage | 220(±1%);230/240(±3%) Vac |
| relative humidity | 0~95 % RH, non-condensing |
| Dimensions | 156×255×295 mm (W × H × D; 1 kVA standard model) |
| Surge immunity | 2 kV (L, N to earth; Level 3) |
| Maximum battery cable length | 30 m |
| Maximum output cable length | 10 m |
| Output waveform | Sine wave |
| Communication interfaces | DB-9 RS-232; Type-B USB |
| Battery Backup Time | ≥4 min |
| Battery Type | Valve-regulated sealed lead-acid battery |
| Output Current Crest Factor | 3:1 |
| Output Frequency Sync Range | 45~55 Hz; 50 Hz system |
| Noise Level | <45 dB |
| Storage Temperature | −40~+70 °C, standard model, excluding battery |
| Output voltage distortion | ≤3 % (Rated linear load) |
| Mains mode overload duration | 10 min (Rated input; load 105%~130%) |
| Bypass overload duration | 10 min (Load 105%~130%; output shutdown if the specified duration is exceeded) |
| Built-in battery configuration | 3×12×7 cells×V×Ah |
| External battery configuration | 3×12×24~200 cells×V×Ah |
| Charging current | Maximum 8; default 6.5; configurable A |
| Nominal battery voltage | 36 Vdc |
| Grid mode efficiency | ≥91 % |
| Wiring conductor size | 14 AWG or 2.1 mm² |
| Recommended input circuit breaker voltage rating | 230/400 Vac |
| Recommended input circuit breaker current rating | 10 A |
| Recommended input circuit breaker breaking capacity | 6 kA |
| External battery DC circuit breaker current rating | 35 A |
| Recommended battery cable size | 8 AWG |
| Periodic battery self-test interval | 0, 3, 6, 9, 12 months |
| Installation Type | Tower |
| Enclosure Color | Black, RAL 7021 |
| Recommended Installation Clearance | 200 mm (between the front and rear sides and the wall or adjacent equipment) |
| Altitude for operation without derating | 2000 m, ambient temperature 40°C |
| Recommended battery operating temperature | 0~25 °C, to maintain the battery design life |
| Battery service life | 3~5 years, normal conditions |
| Electromagnetic compatibility standard | IEC/EN/AS 62040-2 2nd edition; CISPR22 Class A |
| Net Weight | 12 kg (1 kVA standard model) |