Vertiv Liebert CRV4 In-Row Precision Air Conditioner 25kW-45kW Variable Capacity Cooling (VTV-AC-CRV4-ROW) Official Studio Photo 3
VertivModel: Liebert CRV4 Precision AC

Vertiv Liebert CRV4 In-Row Precision Air Conditioner 25-60kW

The Vertiv Liebert CRV4 is a row-based precision cooling solution designed for high-density data center environments, utilizing 380V 3-phase AC input, a DC inverter brushless scroll compressor, and premium EC centrifugal fans to deliver horizontal airflow directly neutralizing cabinet hot spots with an SHF exceeding 0.95.

Instant Engineer & Sales Quotation

Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.

WhatsApp

Clear support from selection to delivery

360°Technical support
N+Service commitment
3Steps shipping
100%Customer satisfaction
Nominal Cooling Capacity
Nominal Cooling Capacity: 25 kW
AC Operating Voltage
工作交流供电电压: 380~415 V
Dimensions
物理结构外形尺寸: 300×1100×2000 mm
Outdoor Operating Temperature
Outdoor Operating Temperature: −20~+45 ℃
Communication Interface and Protocol
Communication Interface and Protocol: RS485;MODBUS-RTU
Compressor type
Compressor Type: 直流无刷变容量压缩机

What this product is

What this product is

CRV4 is an advanced in-row precision cooling module with 300mm/600mm widths, deployed between standard IT racks in cold/hot aisle containment setups. It integrates inverter compressors, electronic expansion valves, backward-curved EC fans, and the iCOM intelligent control platform.

What problem it solves

Eliminates high-density cabinet hotspots and air recirculation issues without the airflow inefficiencies of raised-floor downflow units, preventing short-cycling and driving down the power usage effectiveness (PUE) of mission-critical compute rows.

Who and where it is for

Enterprise and hyperscale cloud data centers, modular aisle containment solutions, edge computing edge facilities, and critical telecommunication switching centers.

Core advantages

  • Ultra-high Sensible Heat Ratio (SHF ≥ 0.95) engineered specifically for dry IT heat dissipation
  • Full inverter architecture (DC scroll compressor + EC fans) smoothly modulating from 20% to 100%
  • 100% full frontal maintenance access requiring zero side or rear service clearance
  • iCOM multi-unit teamwork algorithm coordinating up to 32 units to prevent operational fighting

Technical specifications

Key specificationsValue
Compressor typeCompressor Type: 直流无刷变容量压缩机
AC Operating Voltage工作交流供电电压: 380~415 V
Filter efficiencyFilter Efficiency: 30 %
Full-load currentFull Load Current: 21.7 A
Refrigerant制冷剂类型: R410A
Product seriesProduct Series: Liebert.CRV4 系列风冷精密空调
Nominal Cooling CapacityNominal Cooling Capacity: 25 kW
Outdoor Operating TemperatureOutdoor Operating Temperature: −20~+45 ℃
Dimensions物理结构外形尺寸: 300×1100×2000 mm
Communication Interface and ProtocolCommunication Interface and Protocol: RS485;MODBUS-RTU
Main Circuit Breaker ModelMain Circuit Breaker Model: NDM1-63C40/3
Refrigerant Oil TypeRefrigerant Oil Type: POE型(32-3MAF)
Indoor Unit Refrigerant ChargeIndoor Unit Refrigerant Charge: 2.47 kg
Maximum Design Suction PressureMaximum Design Suction Pressure: 12.4 bar
Source Short-Circuit Ratio RequirementSource Short-Circuit Ratio Requirement: ≥350
Filter Dust RetentionFilter Dust Retention: 90 %
Applicable Supply SystemApplicable Supply System: TN、TT星形接法
Suction Pressure Upper LimitSuction Pressure Upper Limit: 13.4 bar
Suction Pressure Switch Lower LimitSuction Pressure Switch Lower Limit: 4.5 bar
Indoor Operating TemperatureIndoor Operating Temperature: 18~40 ℃
Indoor Operating Relative HumidityIndoor Operating Relative Humidity: 20~60 %RH
Indoor Unit IP RatingIndoor Unit IP Rating: IP20
Minimum Outdoor Operating TemperatureMinimum Outdoor Operating Temperature: −34 ℃
Operating AltitudeOperating Altitude: <1000 m
High Pressure Switch SettingHigh Pressure Switch Setting: 3900 kPa
Cooling FormCooling Form: 风冷单冷源系统(压缩机制冷系统)
Compressor Cooling System ConfigurationCompressor Cooling System Configuration: 变速压缩机,R410A制冷剂;单压缩机单系统
Indoor Fan TypeIndoor Fan Type: EC风机
Heat Exchanger TypeHeat Exchanger Type: V型高效翅片管换热器;表面亲水处理
Electric Heater TypeElectric Heater Type: PTC
Expansion Valve TypeExpansion Valve Type: 电子膨胀阀
Upper Drain Copper Pipe ODUpper Drain Copper Pipe OD: 12.7 mm
Humidifier Inlet Water PressureHumidifier Inlet Water Pressure: 100~700 kPa
Humidifier Inlet ThreadHumidifier Inlet Thread: 3/4"GAS
Humidifier Hose Temperature RequirementHumidifier Hose Temperature Requirement: >90 ℃
Alarm History Storage CapacityAlarm History Storage Capacity: 1000 条
Maximum Indoor-Outdoor Height DifferenceMaximum Indoor-Outdoor Height Difference: +30 m
Maximum Recommended Pipe LengthMaximum Recommended Pipe Length: 50 m
Outdoor Fan Speed Control MethodOutdoor Fan Speed Control Method: 通过压力调节风机转速
Extension Kit Consultation ThresholdExtension Kit Consultation Threshold: >30 m
Drain Port ThreadDrain Port Thread: 1/2"-BSP
Drain Hose Inner DiameterDrain Hose Inner Diameter: 9 mm
Control Interface and Terminal DefinitionControl Interface and Terminal Definition: 51/24漏水;37/38远程开关机;70/71室外机控制;75/76公共告警;61/62 CAN;63/64液路电磁阀;A2/B2/12V/GND SIC卡
Recommended Refrigerant Pipe DiameterRecommended Refrigerant Pipe Diameter: 气管D 19;液管L 12.7 mm
Display Resolution128×64 dot matrix
Maximum Rack Temperature SensorsMaximum Rack Temperature Sensors: 6 个
Drain Pan Hose Inner DiameterDrain Pan Hose Inner Diameter: 16 mm
Temperature/Humidity History RangeTemperature/Humidity History Range: 0~48 小时
Power Terminal BlockPower Terminal Block: L1、L2、L3、N、PE
Fan Speed Control SignalFan Speed Control Signal: 0~10 VDC
Front Service ClearanceFront Service Clearance: 600 mm
Cabinet Mounting Hole DiameterCabinet Mounting Hole Diameter: 13.5 mm
Equipment Net WeightEquipment Net Weight: 235 kg

Applications

01

Modular data center cold/hot aisle containment systems

02

High-power AI training clusters and supercomputing server rows exceeding 15kW/rack

03

Carrier-grade 5G core network equipment rooms and telco central offices

04

Financial colocation data centers demanding high-availability Tier III/IV thermal stability

Frequently asked questions