Huawei AIU03-100C AC Input Unit Power Module (200-240V/346-415V 100A Busbar Blind-Mate)
The Huawei AIU03-100C (02312MUD) is a carrier-grade AC Input Unit power distribution module featuring 100A max current and blind-mate busbar design.

The Huawei TP48600T-N20A6 is an indoor telecom power system that converts 220/380 V AC three-phase four-wire input into -48 V DC for -48 V-series telecom equipment; rectification, distribution and monitoring are combined in one 2000 × 600 × 600 mm cabinet with a maximum output of 600 A.
Need to confirm a model, specification, or project configuration? Our team can follow up by email or phone.
The system combines rectifier modules, AC/DC distribution and the SMU06C2 controller in one cabinet measuring 2000 mm high, 600 mm wide and 600 mm deep. The AC input is 220/380 V three-phase four-wire with a phase-voltage range of 85 - 300 V AC, 45 - 66 Hz, with 50/60 Hz rated and a power factor of at least 0.99 at full load. The DC output spans -42 to -58 V, defaulting to -53.5 V, at up to 600 A; voltage regulation is within ±1 %, current-sharing imbalance stays below ±5 % at 20 - 100 % load, and psophometric noise is at or below 2 mV. Distribution is split into BLVD (important loads) and LLVD (secondary load) branches per user, supporting shared feeding of four users with independent per-user DC metering.
It centralizes -48 V DC feeding for equipment rooms: one cabinet holds rectification, distribution, monitoring and the battery branch, delivering up to 600 A; four users share the supply with independent metering and load-shedding control, which suits multi-tenant sites and operator transmission nodes.
Suited to indoor telecom equipment rooms, operator transmission and aggregation nodes, and multi-user shared rooms that need -48 V DC feeding with independent metering and load-shedding control for four users.
| Key specifications | Value |
|---|---|
| Model | TP48600T-N20A6 |
| Product type | Indoor telecom power system (cabinet) |
| AC input configuration | 220/380 V AC, three-phase four-wire |
| AC input voltage range | 85 - 300 V AC (phase voltage) |
| Input frequency | 45 - 66 Hz (rated 50/60 Hz) |
| Power factor | ≥ 0.99 (rated input, full load) |
| Input total harmonic distortion | ≤ 5 % (input 208/220/230 V AC, 50 - 100 % load) |
| Maximum output current | 600 A |
| Output voltage range | -42 to -58 V DC |
| Default output voltage | -53.5 V DC |
| Output power | Sum of the rectifier module powers (depends on configuration) |
| Voltage regulation accuracy | ≤ ±1 % |
| Current-sharing imbalance | < ±5 % (20 - 100 % load) |
| Psophometric noise | ≤ 2 mV |
| Ripple and noise | ≤ 200 mVp-p |
| Rectifier module configuration | Up to 12 R4850N6 or R4850G2 rectifier modules |
| Monitoring unit | SMU06C2 |
| Multi-user feeding | Shared feeding for four users with independent per-user DC metering |
| Important load branches (BLVD) | Users 1-3 each have four 100 A fuses; user 4 has two 16 A 1-pole breakers |
| Secondary load branches (LLVD) | Users 1-3 each have four 160 A fuses plus three 63 A 1-pole breakers; user 4 has three 63 A breakers |
| Battery branch | Two 500 A fuses |
| Communication interfaces | RS485/RS232 ×1 (NetEco, DND or MODBUS protocol); COM ×1 (master/slave or MODBUS) |
| Cabinet dimensions (H×W×D) | 2000 × 600 × 600 mm |
| Cabinet weight | ≤ 120 kg (without rectifier modules and optional parts) |
| Installation and maintenance | Floor-standing or raised-floor; front service; wall-adjacent (≥ 100 mm) |
| Cable entry | Top cable entry and exit |
| Cooling | Natural cooling |
| Protection rating | IP20 |
| Operating temperature | -20 °C to +50 °C |
| Storage/transport temperature | -40 °C to +70 °C |
| Operating humidity | 5 % - 95 % RH (non-condensing) |
| Operating altitude | 0 - 4000 m (above 2000 m, reduce the maximum permissible operating temperature by 1 °C for every additional 200 m) |
| MTBF | 200000 h (25 °C) |
| AC lightning discharge current | Nominal 20 kA, maximum ±40 kA (8/20 μs waveform) |
| Certifications and standards | IEC/EN 60950-1; EN 300386 Class A; ETSI EN 300 019-1-4 Class 4.1; IEC 61000-4-2/-3/-4/-5/-6 |
Huawei

The Huawei AIU03-100C (02312MUD) is a carrier-grade AC Input Unit power distribution module featuring 100A max current and blind-mate busbar design.

The CT016M501 is a critical hardware component in Huawei indoor telecom power systems, integrating subrack backplane signal routing, high-current busbar power distribution, and low-voltage trip protection.

The DBU50B-N12A3 is a high-performance Huawei 48V 50A DC backup power unit engineered for telecom exchanges, cellular base stations, and critical ICT infrastructures. It integrates high-efficiency AC-DC rectification, intelligent battery charge/discharge regulation, and robust power distribution protection within a standard 19-inch embedded chassis, delivering uninterrupted 48V power to core loads.

The ETP48100-B1 is a high-efficiency power system designed for telecommunication facilities and industrial infrastructure.