Vertiv MP2-220K Sistema de energía industrial - Vista frontal oficial
VertivModelo: MP2-220K

Vertiv MP2-220K Sistema de energía industrial

The Vertiv MP2-220K is a microprocessor-based central supervisory controller designed for 220Vdc utility substations and critical power plants. It integrates full rectifier fleet management, busbar-to-ground insulation monitoring, dual AC source ATS automation, battery test profiling, and feeder ground fault location in a rugged industrial panel-mount enclosure.

El precio se confirma según la configuración y el volumen del proyecto

Solicitar cotización
Monitored DC Bus Voltage
220Vdc (Sampling Accuracy ±0.2%)
Insulation Ground Fault Detection
Busbar & Feeder Resistance Leakage Detection
Human-Machine Interface
Wide-Temperature Graphic LCD with Tactile Keys
Intelligent Battery Management
Temperature Compensated Float/Equalize & Capacity Testing
Substation SCADA Protocols
RS485 / IEC 60870-5-104 / CDT / Modbus-RTU
EMC & Enclosure Standard
Panel Flush Mount / Level 4 Industrial EMC Compliance

Descripción del producto

Descripción del producto

The Vertiv MP2-220K is a microprocessor-based central supervisory controller designed for 220Vdc utility substations and critical power plants. It integrates full rectifier fleet management, busbar-to-ground insulation monitoring, dual AC source ATS automation, battery test profiling, and feeder ground fault location in a rugged industrial panel-mount enclosure.

Problema que resuelve

Resolves power grid instability, operational energy dissipation, and equipment protection challenges.

A quién se dirige y ámbito de aplicación

Critical telecom facilities, data centers, utility substations, and industrial continuous power plants.

Ventajas principales

  • Precision Insulation Monitoring: Combines DC bridge and low-frequency injection methods to locate feeder ground faults in milliseconds.
  • Fleet Energy Optimization: Dynamically controls rectifier on/off states based on real-time load demand to maximize overall efficiency.
  • Comprehensive Battery Diagnostics: Temperature compensation, Ah counting, and auto-equalizing routines maximize battery operational life.
  • Substation SCADA Compatibility: Native support for IEC 60870-5-104, CDT, and Modbus-RTU protocols for seamless RTU integration.

Especificaciones técnicas

Especificaciones claveValor
Monitored DC Bus Voltage220Vdc (Sampling Accuracy ±0.2%)
Insulation Ground Fault DetectionBusbar & Feeder Resistance Leakage Detection
Human-Machine InterfaceWide-Temperature Graphic LCD with Tactile Keys
Intelligent Battery ManagementTemperature Compensated Float/Equalize & Capacity Testing
Substation SCADA ProtocolsRS485 / IEC 60870-5-104 / CDT / Modbus-RTU
EMC & Enclosure StandardPanel Flush Mount / Level 4 Industrial EMC Compliance

Aplicaciones

01

Critical Telecom Infrastructure & DC Plant

02

High-Density Cloud Computing & Enterprise Data Centers

03

Industrial Automation & Utility Substation Systems

Preguntas frecuentes

Seguir explorando

Vertiv