Model: ZXD2400 (V4.2)

ZTE ZXD2400 (V4.2) features optimized dual-grid compatibility (110V/220V) delivering robust -48V/50A output under severe temperature and voltage fluctuations.

## What this product is

Telecom-grade power infrastructure module designed for ZTE power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Wide input voltage range (80VAC–295VAC) adapts to unstable grids, effectively eliminating grid interference.
- Delivers 2400W high-power output (-48V/50A) with hot-swap and N+1 redundancy for zero network downtime.
- Extreme operating temperature range (-25°C to +65°C) with intelligent variable-speed forced-air cooling.
- High conversion efficiency of ≥92.5% significantly reduces central office power consumption and OPEX.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 80VAC ~ 295VAC (30A output for 110V system, 50A output at 220V)
- Cooling method: Forced-air cooling with temperature-controlled intelligent variable-speed fan
- Conversion efficiency: ≥ 92.5%
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Dimensions: 134 × 87 × 290 mm
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Operating Temperature Range: -25°C ~ +65°C

## Frequently asked questions

### Which ZTE power chassis systems support the ZXD2400 (V4.2), and is it backward-compatible with V3.0 or V4.0 modules?

The module is designed for hot-plug deployment in ZTE ZXDU68, ZXDU58, and ZXDU45 DC power enclosures via standard blind-mate backplanes. It integrates autonomous active current-sharing circuitry alongside CAN/RS485 interfaces for CSU supervisory communication. For mixed-rack expansions, V4.2 is fully intermateable with V4.0 (current-sharing imbalance \< 3%). When operating alongside legacy V3.0 units, due to differences in dynamic response and bus protocols, physical segregation into independent shelves or dedicated power sub-racks is recommended to avoid telemetry collisions and uneven load allocation.

### What are the input voltage adaptive range and output power/current derating characteristics of ZTE ZXD2400 (V4.2)?

The ZTE ZXD2400 (V4.2) (SKU: ZTE-REC-ZXD2400-V42) operates across an ultra-wide single-phase AC input range of 80VAC to 295VAC. Under standard 220VAC input (150VAC–295VAC), it provides a nominal -48V DC output (adjustable from -42V to -58V DC) with a rated current of 50A and maximum output power of 2400W. Under 110VAC low-voltage grids (80VAC–150VAC derating window), current is hardware-limited to 30A (~1440W). Featuring active PFC (cosφ ≥ 0.99) and THD ≤ 5%, it achieves a peak rectification efficiency exceeding 92% across diverse worldwide utility environments.

### What are the thermal dissipation and electrical surge protection designs of ZXD2400 (V4.2) under harsh operating conditions?

The module operates from -25°C to +65°C (with intelligent linear thermal derating initiating above +45°C). Cooling is managed via an internal brushless DC smart variable-speed fan driven by junction temperature telemetry. Electrical robustness includes dual-stage AC input varistor suppression capable of withstanding 2kV differential / 4kV common-mode surges. Output circuitry incorporates anti-reverse-feed protection, electronic short-circuit latch/auto-recovery, and hardware-level transient isolation to safeguard battery strings against DC bus surges and catastrophic utility transients.