# ZTE ZXSDR B8300 Multi-Mode Baseband Unit (3U Rack-Mount BBU Chassis)

RICEWIND · ZTE

https://ricewind.com/en/products/zte-zxsdr-b8300-bbu-unit

Model: ZTE ZXSDR B8300 BBU Unit

The ZTE ZXSDR B8300 is a compact 3U 19-inch rack-mount multi-mode indoor Baseband Unit (BBU) engineered for distributed cellular base stations, supporting GSM, UMTS, LTE, and 5G co-sited deployments with high slot density and optical CPRI interfaces.

## What this product is

Standard 3U rack-mount carrier-grade cellular Baseband Unit (BBU) chassis.

## What problem it solves

Decouples baseband processing from radio antennas via fiber optics, drastically cutting transmission line losses and footprint requirements.

## Who and where it is for

Cellular macro sites, micro sites, indoor distributed antenna systems (DAS), and private cellular hubs.

## Core advantages

- Standard 19-inch 3U structural design with high-density slots supporting multi-mode flexible plug-in card capacity expansion.
- Supports smooth evolution of multi-standard GSM/CDMA/WCDMA/LTE in a shared chassis.
- Distributed architecture design reduces site construction costs by extending RRU over long distances via fiber optics.
- Highly reliable dual-power redundancy and intelligent fan speed regulation cooling system.

## Applications

- Data center intelligent power distribution header cabinets and busway telemetry systems
- Master supervisory brain for telecom power plants and autonomous parallel rectifier fleets
- Substation battery bank string telemetry, cell impedance monitoring, and predictive alarms
- Integrated power and environment automation for remote unattended telecom hub stations

## Technical specifications

- Board Type: 3U 19-Inch Rackmount
- Port Density & Specs: Multi-slot modular high-density backplane architecture
- Supported Chassis: smooth evolution with GSM / UMTS / LTE / 5G multimode operation in one chassis
- Subscriber Capacity: Long-distance fiber-optic extension of the RRU radio frequency unit, significantly reducing equipment-room footprint and feeder loss
- Typical power consumption (W): Dual Redundant DC Power Supply (-48V DC) W
- Non-Volatile Log Capacity: 10,000+ Cyclic Event Records
- Operating Temperature Range: -20 ~ +55°C
- Unit Power Consumption: \< 8W (Ultra-Low Standby Design)
- Industrial EMC Level: EN 55032 Class A / IEC 61000-4 Level 4
- Relative Humidity Tolerance: 5% to 95% RH (Non-Condensing)

## Frequently asked questions

### How do I choose the right ZTE ZXSDR B8300 BBU Unit for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is ZTE ZXSDR B8300 BBU Unit compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for ZTE ZXSDR B8300 BBU Unit?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for ZTE ZXSDR B8300 BBU Unit?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply ZTE ZXSDR B8300 BBU Unit?

Yes. RICEWIND supplies ZTE ZXSDR B8300 BBU Unit with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for ZTE ZXSDR B8300 BBU Unit?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of ZTE ZXSDR B8300 BBU Unit.

### What are the core electrical power specifications and optical CPRI/eCPRI transmission parameters of the ZTE ZXSDR B8300 BBU?

The ZTE ZXSDR B8300 operates on a telecom-grade -48V DC power system (operational voltage range: -40V DC to -57V DC) featuring dual-feed 1+1 redundant power modules (PM). The typical chassis power consumption ranges from 300W to 650W depending on board configurations, with maximum full-load power ≤ 800W. For baseband-to-RRU connectivity, the high-speed passive backplane works with baseband boards (such as UBPG, BPK, and BPN series) utilizing SFP/SFP+ transceivers. It supports CPRI line bit rates from Option 2 through Option 8/10 (up to 24.33 Gbps) as well as eCPRI. The standard optical transmission reach spans 10 km to 20 km over single-mode fiber (1310nm/1550nm) and can be extended up to 40 km via WDM architectures, eliminating feeder line losses and reducing footprint.

### How does the ZXSDR B8300 slot architecture handle GSM/UMTS/LTE/5G multi-mode co-existence and smooth capacity expansion?

Engineered with a 3U 19-inch rack-mount profile, the ZXSDR B8300 features a modular backplane offering dedicated slots for redundant Main Control & Switching boards (CC/CC16/CC17 in active/standby mode), up to 6 universal baseband processing slots, fan trays (SA/FA), and power modules (PM). With hundreds of Gbps non-blocking switching throughput across the backplane, it natively enables GSM, UMTS, LTE FDD/TDD, and 5G NR co-chassis operation. Capacity expansion is achieved without chassis replacement: operators can hot-swap or mix-and-match specialized processing boards (e.g., adding BPN2 boards for 5G NR deployment alongside UBPG3 boards for legacy 2G/3G/4G traffic). Dynamic microcode upgrades on the control board ensure a completely seamless migration path.

### What are the thermal design, surge protection, and MTBF reliability metrics of the B8300 under demanding site conditions?

Engineered for both telecom equipment rooms and outdoor integrated telecom cabinets, the ZTE B8300 supports an operating temperature range of -20°C to +55°C and relative humidity from 5% to 95% non-condensing. The thermal subsystem relies on hot-swappable intelligent fan trays featuring PWM speed modulation and multi-point thermal sensors, delivering high-efficiency forced-air cooling that maintains full-load operation even during single-fan failure. Electrically, the power feed modules feature comprehensive protection against overvoltage, undervoltage, overcurrent, short circuits, and reverse polarity, fully meeting IEC 61000-4-5 surge immunity requirements (2kV differential mode, 4kV common mode). The system delivers a carrier-grade MTBF exceeding 320,000 hours with 99.999% availability.