# ZTE ZXDU60 S301 R10M01 Indoor DC Power Cabinet System (-48V 300A LLVD/BLVD Contactors CSU Smart Monitoring)

RICEWIND · ZTE

https://ricewind.com/en/products/zte-zxdu60-s301-r10m01

Model: ZXDU60 S301 R10M01

The ZTE ZXDU60 S301 R10M01 is an industrial-grade telecom power infrastructure unit engineered for high-reliability base stations and mission-critical edge facilities.

## What this product is

A carrier-grade power unit designed by ZTE to deliver stable DC/AC electricity under demanding grid conditions and harsh outdoor environments.

## What problem it solves

Eliminates unexpected site downtime caused by AC utility voltage surges, severe brownouts, and load transient disruptions.

## Who and where it is for

Telecom macro sites, small cells, edge computing nodes, optical transport nodes, and railway signaling power systems.

## Core advantages

- Ultra-wide operating voltage tolerance for volatile utility grids
- Advanced digital control loop delivering exceptional peak efficiency
- Full hot-swappable architecture with integrated surge & over-current protection
- Industrial long-life components with superior MTBF reliability

## Applications

- Telecom carrier macro and micro BTS DC power distribution
- Edge computing data center infrastructure backup
- Industrial automation and communication transmission nodes

## Technical specifications

- Rated System Output Capacity: 300A (Expandable up to 6x 50A Rectifier Modules)
- Nominal DC Output Voltage: -48VDC Nominal (Adjustable -42VDC ~ -58VDC)
- Monitoring Controller Unit: Integrated CSU Smart Monitoring Controller with LCD
- Form Factor & Mounting: 1.6m / 2.0m Indoor Integrated Telecom Power Cabinet
- Wide Operating Temperature Range: -25°C ~ +55°C
- Input Voltage Range: Three-phase 380VAC / Single-phase 220VAC
- system\_efficiency: ≥96.5% with High-Efficiency Rectifiers
- DC Distribution Configuration: Dual Battery Disconnects, Multichannel Critical & Non-critical DC Breakers

## Frequently asked questions

### Is ZXDU60 S301 R10M01 compatible with existing batteries, generators, and rectifiers?

Compatibility depends on DC bus voltage, telemetry protocols, and mechanical form factors. Describe your existing site setup and RICEWIND engineers can verify integration feasibility before you order.

### How is ZXDU60 S301 R10M01 delivered? Does RICEWIND provide international shipping?

Power systems are packed in heavy-duty export-standard wooden crates for sea or air transport. RICEWIND ships worldwide — contact us to confirm inventory, freight options, and delivery schedules.

### What warranty and engineering support are available for ZXDU60 S301 R10M01?

Warranty follows the manufacturer policy for the specific configuration. RICEWIND supports wiring schematics, remote commissioning guidance, spare parts, and engineer-level technical assistance.

### Does RICEWIND supply ZXDU60 S301 R10M01?

Yes. RICEWIND supplies ZXDU60 S301 R10M01 with MOQ from 1 system; in-stock units dispatch within 24-48 hours with global logistics coverage.

### Is there a cross-reference or equivalent replacement for ZXDU60 S301 R10M01?

RICEWIND maintains a cross-reference matrix covering Huawei, Vertiv, Eltek, and ZTE telecom power systems. Contact us for direct equivalents and expansion options for ZXDU60 S301 R10M01.

### How do I plan and configure ZXDU60 S301 R10M01 for my telecom site?

Consider total DC load, N+1 redundancy, battery autonomy backup time, surge protection, and cabinet footprint. Share your project requirements with RICEWIND and we will propose a matched configuration.

### What are the AC distribution options and surge suppression ratings of ZXDU60 S301?

Supports three-phase 380VAC or single-phase 220VAC inputs. It integrates a Class C lightning surge arrester rated for In=20kA and Imax=40kA (8/20μs) with local visual failure indicators.

### How are Load Low Voltage Disconnect (LLVD) and Battery Low Voltage Disconnect (BLVD) configured?

Dual independent DC contactors manage disconnection: LLVD sheds non-critical telecom loads at -47.0VDC, while BLVD disconnects critical transmission loads at -43.2VDC to prevent catastrophic battery exhaustion.

### What southbound and northbound communication protocols are supported by the CSU supervisor?

The CSU controller features Fast Ethernet, RS485 ports, and dry contact relays. It natively supports SNMP v1/v2c/v3 and standard telecom protocols for seamless integration into central EMS/NMS platforms.

Content updated: 2026-09-25T09:32:42.182Z