# ZTE ZXD3000 (V5.1) High-Frequency Telecom Rectifier Module (48V 50A 3000W Classic Subrack Module)

RICEWIND · ZTE

https://ricewind.com/en/products/zte-zxd3000-v5-1-rectifier

Model: ZXD3000 (V5.1)

The ZTE ZXD3000 (V5.1) is a renowned classic 50A telecom rectifier module deployed in carrier networks globally, supplying -48V 50A (3000W) with extreme electrical durability, low field RMA, and precise digital current sharing.

## What this product is

The ZTE ZXD3000 (V5.1) is a renowned classic 50A telecom rectifier module deployed in carrier networks globally, supplying -48V 50A (3000W) with extreme electrical durability, low field RMA, and precise digital current sharing.

## What problem it solves

Resolves severe power grid instability, excessive OPEX energy dissipation, battery degradation, and cabinet thermal constraints.

## Who and where it is for

5G cellular cell sites, core telecom DC plants, data center critical power infrastructure, railway signaling, and industrial UPS.

## Core advantages

- Millions of Proven Field Hours: One of ZTE's most battle-tested rectifiers across global Tier-1 telecom carriers.
- Ultra-Wide AC Grid Ingestion: Sustains reliable DC feeding across 80V to 300V AC without needing external line conditioners.
- Autonomous Dynamic Current Sharing: Paralleling imbalance below ±3% with tool-free hot-swap expansion agility.
- Multi-Layer Hardware Protection: Input UVLO, output latching OVP, continuous short-circuit immunity, and thermal derating.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC Input Voltage: 80V - 300V AC Wide Tolerance
- Rated Output VA / Wattage: 3000W Continuous Output
- Chassis Form Factor: 132 × 85 × 290 mm
- Rated DC Output Current: -48VDC (-42V ~ -58V)
- Nominal DC Output Voltage: -48VDC (-42V ~ -58V)
- Peak Energy Efficiency: ≥ 96.0%
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I choose the right ZXD3000 (V5.1) for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is ZXD3000 (V5.1) compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for ZXD3000 (V5.1)?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for ZXD3000 (V5.1)?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply ZXD3000 (V5.1)?

Yes. RICEWIND supplies ZXD3000 (V5.1) with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for ZXD3000 (V5.1)?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of ZXD3000 (V5.1).

### Can the ZXD3000 (V5.1) directly replace older V5.0 or V4.0 modules?

V5.1 and V5.0 share identical pinouts and are 100% plug-compatible; verify controller firmware when retrofitting V4.0 racks.

### How do you clear a persistent Red alarm indicator on the ZXD3000 (V5.1)?

Power-cycle the AC input breaker for 60 seconds to reset latching overvoltage. If alarm persists, inspect cooling fan.

### How does the hardware protection engage during DC output overvoltage or short circuit?

Features dual sub-millisecond hardware latching: overvoltage triggers immediate output shutdown and latching alarm; short circuits trigger self-recovering hiccup constant current limiting.

Content updated: 2026-09-20T12:21:10.909Z