# Zhujiang SMR3004D High-Power Telecom Base Station Rectifier Module (48V 50A 2900W)

RICEWIND · Zhujiang

https://ricewind.com/en/products/zhujiang-smr3004d-b31

Model: SMR3004D

The Zhujiang SMR3004D is a carrier-grade high-power switch-mode rectifier module engineered for telecommunication networks, delivering a nominal 48V DC output at up to 50A and a rated power of 2900W with an adjustable operating range of 42V to 58V DC.

## What this product is

Architecturally, the SMR3004D consists of a high-efficiency front-end APFC stage that accepts a wide 90V to 290V AC input, achieving a power factor above 0.99 while mitigating total harmonic distortion (THD). The isolated DC-DC stage employs full-bridge soft-switching resonance to produce a low-ripple, highly stabilized 48V DC supply. An onboard supervisory microcontroller monitors thermal sensors, phase parameters, and feedback loops to control autonomous single-wire parallel current sharing, precise current limit curves, and multi-tier protection circuits against input transients, output overvoltage clamping (OVP), short circuits, and thermal runaway in compliance with global telecom EMC and safety standards.

## What problem it solves

The SMR3004D addresses operational challenges in remote telecom base stations subject to unstable, fluctuating AC mains. Its 90V~290V AC dynamic tolerance eliminates frequent rectifier dropouts and battery cycle exhaustion in rural grids. Integrated thermal derating algorithms prevent catastrophic thermal failures in enclosed outdoor cabinets, while its zero-arcing hot-swappable interface allows live module replacement without inducing DC bus transients or telecom transmission dropouts.

## Who and where it is for

Optimized for 4G/5G macro BTS power plants, central office (CO) telecom power racks, distributed cellular shelter sites, microwave transmission links, and industrial DC UPS systems for utility automation and railway communications.

## Core advantages

- Ultra-Wide AC Input Range: Supports 90V-290V AC input with built-in APFC achieving a power factor \>0.99, mitigating harsh grid fluctuations.
- High-Efficiency Soft-Switching Conversion: Utilizes a two-stage topology with resonant soft-switching, delivering ≥92.0% peak efficiency at 2900W.
- Intelligent Current Sharing & Protection: Features digital parallel active current sharing, hot-swap capability, and comprehensive OVP/SCP hardware protection.
- Rugged Industrial Reliability: Engineered for telecom sites with -25°C to +65°C operating range and smart thermal management to prevent thermal runaway.

## Applications

- Telecom macro base station 48V power plant retrofits and parallel rack capacity expansions
- Outdoor integrated telecom enclosures deployed in weak grid and harsh temperature environments
- Central office (CO) core routing and switching transmission room DC backup power distribution
- Critical railway signaling and trackside communication shelter uninterrupted DC power plants

## Technical specifications

- Rated Output Voltage: -48VDC (-42V ~ -58V)
- AC Input Voltage: 90V AC ~ 290V AC
- Maximum Output Current: 50A
- Rated Output Power: 2900W
- Maximum Efficiency: ≥ 92.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select SMR3004D for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is SMR3004D compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for SMR3004D?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to SMR3004D?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply SMR3004D from stock?

Yes. RICEWIND supplies SMR3004D from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for SMR3004D?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of SMR3004D.

### Does the SMR3004D maintain its full 2900W / 50A rating when operating under low AC input voltages such as 110V AC?

No. The SMR3004D incorporates an automatic input-voltage power derating profile. It delivers full rated power (2900W, up to 50A) across the nominal grid window of 176V to 290V AC. When the input voltage drops between 90V and 176V AC, the internal controller progressively derates the maximum allowable output current to protect the input bridge rectifier and boost MOSFETs from overcurrent stress, ensuring uninterrupted operation without tripping.

### What does a steady or blinking yellow LED indicator on the front panel signify, and what field diagnostic steps are required?

A yellow LED indicates a warning or operational limitation condition, such as input AC abnormal (undervoltage or overvoltage), output current limiting, or high-temperature derating. Technicians should measure the incoming AC phase-to-neutral voltage at the rear backplane to verify it is within the 90V~290V AC limit, inspect the front air intake and exhaust vents for thermal blockage or dust accumulation, and confirm the total shelf load has not exceeded the aggregated rectifier capacity.

### What engineering precautions should be observed when hot-swapping an SMR3004D under full bus load?

Although the SMR3004D features staggered backplane connector pins and inrush pre-charging circuits for hot-plug safety, field personnel should loosen the panel retaining screws and release the extractor handle smoothly. This action trips the auxiliary interlock contact, disabling the PWM control before power pins disengage. When inserting a replacement module, align the guide rails, slide it firmly into the backplane, lock the handle, and tighten the retaining screws to ensure reliable mechanical earth bonding.

### How do you clear an output overvoltage protection (OVP) latch condition on the SMR3004D?

When the SMR3004D detects an output voltage exceeding its internal hardware safety threshold (typically 59V~60V DC), it immediately clamps the PWM drive, illuminates the red alarm LED, and latches off to protect downstream load electronics. To reset this latch, the module must be unseated from the subrack or isolated via its corresponding AC input breaker for at least 20 to 30 seconds to allow the internal primary bus capacitors to fully discharge before repowering.

Content updated: 2026-09-17T01:30:03.346Z