# Zhujiang SMPS2004 Industrial Switch-Mode DC Power Rectifier Module (48V 30A 1700W)

RICEWIND · Zhujiang

https://ricewind.com/en/products/zhujiang-smps2004-b31

Model: SMPS2004

The Zhujiang SMPS2004 is an industrial-grade high-frequency switch-mode DC power rectifier module designed to convert standard single-phase AC utility into a highly regulated 48V DC nominal output (adjustable between 42V and 58V DC), delivering a continuous maximum output current of 30A with a rated capacity of 1700W.

## What this product is

Architecturally, the SMPS2004 utilizes a two-stage conversion platform consisting of a wide-range active PFC boost pre-regulator (PF ≥ 0.99) followed by a high-frequency isolated DC-DC resonant power stage. The internal circuitry incorporates multi-stage EMI filtering compliant with carrier-grade EMC directives and heavy-duty surge suppression. The module interfaces via a blind-mate rear connector featuring staged pin lengths for pre-charge, power buses, autonomous current-sharing signals, and system communication buses to guarantee seamless live hot-swapping.

## What problem it solves

It mitigates common industrial grid threats such as severe brownouts, voltage sags, and high-energy transients that typically drop standard power supplies offline. Its dynamic power-limiting profile prevents source generator overload during cold starts, while live hot-swap capabilities and autonomous active current sharing eliminate single points of failure, radically reducing system downtime and emergency maintenance costs.

## Who and where it is for

Ideal for telecom operator macro base stations, micro BTS cabinets, optical line terminal (OLT) shelters, power utility DC distribution panels, railway signaling rooms, and rugged industrial 48V DC battery backup systems.

## Core advantages

- Wide Input & PFC: 90V-290V AC range with ≥0.99 active PFC effectively resists grid brownouts and surge fluctuations.
- Reliable Two-Stage Topology: Features high-frequency isolated DC-DC bridge and step-down power limiting for stable weak grid/generator operation.
- Efficient Hot-Swap Architecture: Peak efficiency ≥91.5%, gold-finger blind-mate hot-swapping, and autonomous current sharing for zero downtime.
- Rugged Industrial Compliance: Operates from -20°C to +65°C with built-in EMI filtering and surge suppression, fully IEC/EN compliant.

## Applications

- Parallel rectification and battery float/equalize charging inside 4G/5G macro cell outdoor power enclosures
- Central office optical transmission and broadband FTTx node 48V DC centralized distribution racks
- Substation SCADA automation, protection relaying, and telecontrol DC switchboards
- Industrial automation controllers, edge IoT gateways, and manufacturing plant auxiliary DC emergency supplies

## Technical specifications

- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 30A
- Rated Output Power: 1700W
- AC Input Voltage: 90V AC ~ 290V AC
- Maximum Efficiency: ≥ 91.5%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select SMPS2004 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is SMPS2004 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for SMPS2004?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to SMPS2004?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply SMPS2004 from stock?

Yes. RICEWIND supplies SMPS2004 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for SMPS2004?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of SMPS2004.

### What is the output power derating behavior of the SMPS2004 when AC input drops below 176V AC?

The module delivers its full 1700W (48V/30A) rating when the input voltage is maintained between 176V AC and 290V AC. When input voltage drops between 90V AC and 176V AC, the internal APFC supervisor automatically applies linear power derating to keep input current within safe thermal limits. At the 90V AC lower limit, the maximum output power smoothly scales down to approximately 50% without dropping offline.

### How should field technicians diagnose a persistent red alarm LED with zero DC output?

First, measure the AC input line voltage to ensure it sits within the 90V to 290V AC operating envelope. Second, check the DC load bus for an external dead short or reversed battery connection. Third, verify that air intakes and exhaust pathways are clear of blockages that cause thermal shutdown. Finally, determine if an output overvoltage protection (OVP) state has latched; if OVP has triggered, disconnect the AC input entirely, wait 3 minutes for internal bulk capacitors to discharge, and re-apply power.

### How does the module achieve load balancing when multiple SMPS2004 units are installed in a shared subrack?

The module connects to a dedicated active current-sharing bus via its rear blind-mate interface pinout. When slotted into a compatible Zhujiang power backplane, the internal current-sharing circuitry dynamically compares each unit's output with the bus reference and trims the PWM control loop. This autonomous mechanism guarantees load sharing accuracy within ±5% across 50% to 100% load conditions without requiring central controller intervention.

### What preventative maintenance schedule is recommended for the cooling fan in harsh environments?

Inspect and clear the front intake grille and internal heatsink fins every 6 to 12 months using clean, dry compressed air. Verify via the shelf monitor that the fan modulates smoothly across load levels without bearing noise. If fan lock or failure occurs, the unit will issue an alarm and throttle its output under high ambient conditions; the fan assembly should then be swapped with an original manufacturer replacement unit.

Content updated: 2026-09-17T01:30:04.530Z