# Vertiv S48-3000 Solar-Hybrid Dual-Input Telecom Power Rectifier Module (48V 3000W)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-s48-3000-b31

Model: S48-3000

The Vertiv S48-3000 is a carrier-grade, high-efficiency solar-hybrid switch-mode rectifier module delivering a nominal -48V DC output (adjustable from -42V to -58V DC) and 3000W rated power (up to 60A output current). Engineered for telecom power and renewable energy integration, it seamlessly accommodates an ultra-wide AC input range (85V AC to 300V AC) as well as MPPT solar inputs with peak conversion efficiencies exceeding 96.0%.

## What this product is

Architecturally, the S48-3000 integrates an active power factor correction (APFC) circuit, a flexible high-voltage DC-DC stage compatible with MPPT solar controllers, and an isolated resonant LLC DC-DC converter. It is built with an independent front-to-back airflow channel, conformal-coated industrial-grade printed circuit boards, and complete CAN bus telemetry, fully compliant with global telecom safety standards such as IEC/EN 60950 and Telcordia GR-1089-CORE.

## What problem it solves

It eliminates the high fuel dependencies, elevated maintenance overhead, and carbon footprints of diesel-generator-dependent telecom towers in weak or off-grid areas. Moreover, its wide input voltage envelope prevents field rectifier burnouts from severe mains surges, while full hot-plug support removes the risk of DC system downtime during scheduled field maintenance.

## Who and where it is for

Ideal for cellular 4G/5G macro sites, hybrid solar-diesel-battery telecom installations, off-grid microwave relay stations, and mission-critical telecom outdoor power cabinets requiring flexible solar and AC grid rectified -48V DC power.

## Core advantages

- Integrated MPPT and AC dual-input architecture enables smart multi-energy scheduling, drastically reducing diesel generator dependency for remote sites.
- Advanced APFC circuit and wide input voltage range (85V-300V AC) withstand severe grid fluctuations and surges, preventing overvoltage breakdown.
- Delivers 3000W rated power with peak conversion efficiency exceeding 96.0%, effectively minimizing telecom site energy consumption and carbon footprint.
- Supports hot-swappable technology and sealed dustproof air ducts, complying with IEC/EN safety and EMC Class B standards for maintenance-free reliability.

## Applications

- Hybrid renewable solar-grid telecom power systems deployed at remote cell sites
- 5G wireless macro base station outdoor power retrofit projects for carbon reduction
- Off-grid mountain microwave repeater stations and border surveillance power enclosures
- Railway signaling and utility communications equipment rooms requiring carrier-grade -48V DC

## Technical specifications

- AC Input Voltage: 85V AC ~ 300V AC / MPPT Solar Input
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Rated Output Power: 3000W
- Maximum Output Current: 60A
- Maximum Efficiency: ≥ 96.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select S48-3000 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is S48-3000 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for S48-3000?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to S48-3000?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply S48-3000 from stock?

Yes. RICEWIND supplies S48-3000 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for S48-3000?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of S48-3000.

### What causes the S48-3000 yellow indicator to illuminate with zero DC output after slotting into a NetSure rack?

The yellow LED indicates a protection or warning state. First, check if the AC or solar input voltage is outside the operating threshold (below 85V AC or above 300V AC). Second, inspect the rear blind-mate connector pins for physical misalignment or bent CAN bus pins. Finally, ensure the central controller (e.g., NCU) has not issued a remote shutdown command or set an unassigned rectifier address conflict.

### How does the S48-3000 handle high ambient temperatures above 55°C in outdoor cabinets?

The module utilizes an automatic internal DSP-driven thermal derating algorithm. It delivers full rated 3000W output from -40°C up to +55°C. When ambient temperatures rise from +55°C toward the +75°C limit, the controller smoothly derates output current to preserve internal semiconductor junction temperatures, preventing catastrophic thermal shutdown while maintaining site loads.

### The module fan operates at maximum RPM continuously with an intermittent over-temperature alarm. How should it be serviced?

Continuous max fan speed combined with over-temperature alerts indicates restricted airflow or fan tachometer issues. Safely hot-extract the module and inspect the front intake grille and internal heatsinks for dust or debris blockages; clean thoroughly using dry, oil-free compressed air. If the airflow is clear and the alarm persists, the fan assembly or internal NTC temperature sensor is likely degraded and requires replacement.

### Are there specific procedures required when hot-swapping an S48-3000 under live load conditions?

Yes. Release the front locking latch screw, pull the extraction handle forward to disengage the rear blind-mate connector in one smooth, horizontal motion without tilting. When inserting a replacement, align the unit with the subrack guide rails and slide it firmly until the rear connector seats fully—the ground pin contacts first, followed by power and CAN lines. Fasten the locking latch to re-establish dynamic bus communications.