# Vertiv RP1V2001 Intelligent Power Distribution Monitoring Module (Multi-Circuit AC/DC Telemetry DIN-Rail)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-rp1v2001-modular-distribution-monitor

Model: RP1V2001

The Vertiv RP1V2001 is a compact DIN-rail mounted power distribution telemetry module engineered for precision power distribution cabinets (PDC) and telecom DC frames. It features multi-channel high-precision AC/DC voltage/current analog acquisition and digital status inputs to track circuit breaker positions and fuse alarms in real time.

## What this product is

The Vertiv RP1V2001 is a compact DIN-rail mounted power distribution telemetry module engineered for precision power distribution cabinets (PDC) and telecom DC frames. It features multi-channel high-precision AC/DC voltage/current analog acquisition and digital status inputs to track circuit breaker positions and fuse alarms in real time.

## What problem it solves

Resolves power grid instability, excessive OPEX energy dissipation, battery degradation, and rack footprint constraints.

## Who and where it is for

5G cellular cell sites, core telecom DC plants, AI data centers, transport networks, and critical industrial DC UPS.

## Core advantages

- High-Density Multi-Branch Telemetry: Captures dozens of breaker auxiliary contacts and Hall current signals in a compact DIN footprint.
- DC Bus Self-Powered: Wide 18Vdc to 60Vdc input operates directly from the -48Vdc bus without needing dedicated auxiliary power adapters.
- 3000Vrms High-Voltage Isolation: Complete galvanic isolation on communication and sampling ports shields circuitry from lightning surges.
- Plug-and-Play DCIM Mapping: Integrates natively with Vertiv NetSure controllers and third-party facility telemetry platforms.

## Applications

- Data center intelligent power distribution header cabinets and busway telemetry systems
- Master supervisory brain for telecom power plants and autonomous parallel rectifier fleets
- Substation battery bank string telemetry, cell impedance monitoring, and predictive alarms
- Integrated power and environment automation for remote unattended telecom hub stations

## Technical specifications

- Auxiliary Power Supply Range: 18Vdc - 60Vdc (Direct Telecom DC Bus Powered)
- Upstream Telemetry Bus: Isolated RS485 Bus / Standard Modbus-RTU
- Mechanical Mounting Standard: 35mm Industrial DIN-Rail Snap-On
- Measurement Accuracy Class: Voltage Class 0.2 / Current & Power Class 0.5
- Analog Acquisition Channels: Multi-Channel Voltage & Hall Effect Current Inputs
- Auxiliary Digital Inputs: Multi-Channel Dry Contact Auxiliary Switch & Fuse Alarms
- Non-Volatile Log Capacity: 10,000+ Cyclic Event Records
- Unit Power Consumption: \< 8W (Ultra-Low Standby Design)
- Industrial EMC Level: EN 55032 Class A / IEC 61000-4 Level 4
- Relative Humidity Tolerance: 5% to 95% RH (Non-Condensing)

## Frequently asked questions

### How do I choose the right RP1V2001 for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is RP1V2001 compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for RP1V2001?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for RP1V2001?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply RP1V2001?

Yes. RICEWIND supplies RP1V2001 with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for RP1V2001?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of RP1V2001.

### How do you calibrate current measurement drift on the RP1V2001?

Drift is typically caused by Hall sensor zero-point offset. Access the sensor calibration menu via the supervisory controller and perform a zero-offset calibration with the branch circuit completely unloaded.

### Where is the RS485 address DIP switch located on the RP1V2001, and how is baud rate set?

An 8-position DIP switch is located on the side panel. Positions 1 to 6 define the Modbus address (1-63), while positions 7 and 8 select the communication baud rate (9600/19200bps).

### Can rectifiers maintain autonomous operation if communication with the controller is lost?

Yes. Rectifiers feature decentralized intelligence: upon supervisory bus loss, units automatically fall back to preset default float voltage (e.g. -53.5Vdc) with autonomous droop load sharing.

Content updated: 2026-09-22T05:43:05.770Z