# Vertiv R48-1000E3 Ultra-Compact High-Efficiency Telecom Rectifier Module (-48V 20A 1000W)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-r48-1000e3-b31

Model: R48-1000E3

The Vertiv R48-1000E3 is an ultra-compact, high-efficiency telecom switch-mode rectifier module delivering a nominal -48V DC output (-42V to -58V DC adjustable), 20A maximum continuous current, and 1000W rated capacity. It converts standard single-phase AC utility or high-voltage DC power into high-integrity telecom-grade DC power to energize telecommunication loads and maintain connected backup battery banks.

## What this product is

Architecturally, the R48-1000E3 utilizes a two-stage high-frequency power conversion design. The front-end active PFC stage delivers a power factor of up to 0.99 and exceptionally low total harmonic distortion (THD) across an ultra-wide AC line window. The isolated DC-DC stage features a resonant LLC soft-switching topology operating with zero voltage switching (ZVS) to minimize switching stress. Internal operations are governed by a central DSP that communicates diagnostics, status, and control parameters over an integrated CAN bus interface via blind-mate backplane connectors.

## What problem it solves

Eliminates unexpected telecom power outages caused by extreme electrical surges, sustained brownouts, and volatile grid fluctuations through its 85V AC to 300V AC operational envelope. It prevents thermal overload shutdowns in compact outdoor cabinets through dynamic load-dependent fan curves, and safeguards against catastrophic DC bus collapse via autonomous overvoltage latching, active current sharing, and reverse-polarity isolation.

## Who and where it is for

Tailored for 4G/5G remote radio heads and baseband unit (BBU/RRU) enclosures, fiber-to-the-home (FTTx) optical line terminals, industrial microwave repeaters, enterprise edge telecom cabinets, and Vertiv NetSure 211, 212, and 531 DC power shelves requiring compact -48V subrack modular power.

## Core advantages

- Ultra-wide AC input voltage range (85V~300V AC) effectively withstands severe grid fluctuations and remote site undervoltage.
- Advanced active PFC and fully digital LLC resonant soft-switching topology achieve peak conversion efficiency over 95.5%.
- Wide operating temperature range (-40°C to +75°C) with intelligent speed fan cooling ensures no derating in high-density deployments.
- Supports live hot-swappable operation and CAN bus digital real-time monitoring with comprehensive hardware-level multi-protection.

## Applications

- 4G/5G macro and micro base station BBU/RRU compact power racks
- FTTx access networks and OLT edge optical distribution enclosures
- Electric utility supervisory control and data acquisition (SCADA) DC nodes
- Enterprise broadband, core routing, and edge-computing telecom cabinets

## Technical specifications

- AC Input Voltage: 85V AC ~ 300V AC
- Rated Output Voltage: -48VDC (-42V ~ -58V)
- Maximum Output Current: 20A
- Rated Output Power: 1000W
- Maximum Efficiency: ≥ 95.5%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Forced Air Cooling with Intelligent Speed Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select R48-1000E3 for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is R48-1000E3 compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for R48-1000E3?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to R48-1000E3?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply R48-1000E3 from stock?

Yes. RICEWIND supplies R48-1000E3 from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for R48-1000E3?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of R48-1000E3.

### What conditions cause the yellow indicator on the R48-1000E3 to illuminate steadily?

A solid yellow LED indicates an operational warning or non-critical protection mode. The most common causes are an AC input voltage drop below 176V AC (which triggers an automated linear power derating down to 85V AC), or an internal ambient temperature exceeding 55°C leading to thermal derating. Verify line voltage at the AC terminals and ensure the front intake and rear exhaust vents are unobstructed.

### Does live hot-swapping an R48-1000E3 module create voltage spikes or arcing on the live DC bus?

No. The module incorporates staggered blind-mate connector pins where protective earth and pre-charge resistors engage prior to the primary power pins. Along with internal inrush-limiting circuitry and DSP soft-start, the module equalizes potential smoothly without generating contact arcing or bus voltage dips.

### How do you recover an R48-1000E3 module that has latched off with a solid red alarm LED?

A persistent red LED denotes an unrecoverable alarm condition, typically an output overvoltage protection (OVP) latch event (\>59V DC). To reset the DSP logic, disconnect the module's AC input circuit breaker, wait approximately 60 seconds until internal DC-bus storage capacitors are completely discharged, and re-energize the unit. If the red LED reappears immediately upon power-up, an internal hardware failure has occurred requiring module replacement.

### Can R48-1000E3 high-efficiency modules be mixed with legacy R48-1000 standard-efficiency modules in the same shelf?

Yes. The mechanical footprint, backplane pin layout, and CAN communication protocols are fully backward compatible. Vertiv NetSure controllers (such as NCU or ACU+) will correctly identify the module and manage autonomous active current sharing. However, to maximize operational efficiency and maintain uniform thermal distribution, uniform module deployment is recommended.

Content updated: 2026-09-17T01:30:51.271Z