# Vertiv Liebert GXE2 UPS 6-20kVA

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-liebert-gxe2-b27

Model: Liebert GXE2

Vertiv Liebert GXE2 is an industrial-grade, high-reliability solution engineered for mission-critical telecom sites, data centers, and power applications.

## What this product is

Vertiv Liebert GXE2 incorporates carrier-grade components and a high-density modular architecture to ensure exceptional uptime and low operational costs.

## What problem it solves

Eliminates downtime risks associated with severe grid fluctuations, harsh ambient temperatures, dense thermal loads, and single-point system failures.

## Who and where it is for

Telecom base stations, hyperscale data centers, enterprise server rooms, edge computing nodes, and harsh industrial automation setups.

## Core advantages

- Industry-leading energy conversion efficiency minimizing long-term OPEX and site PUE.
- Ultra-wide input voltage and temperature operating envelope designed for extreme grid conditions.
- Live hot-swappable modularity enabling seamless tool-less field maintenance with zero service downtime.
- Intelligent telemetry and monitoring telemetry compatible with open industry management protocols.

## Applications

- Telecom cellular base stations and central offices -48V DC backup battery strings
- Data center high-rate UPS battery banks delivering critical runtime for server loads
- Electric utility substations 110V/220V DC switchgear breaker trip and closing power
- Off-grid renewable solar/wind hybrid storage and industrial uninterruptible backup sites

## Technical specifications

- Rated output power: 额定输出功率: 5.4 / 9 / 13.5 / 18 kW
- Electrical Safety Protection: 电气安全防护等级: IP20
- Default charging current: Charge Current: ≤5 / ≤2 / ≤8 / ≤4 / ≤13 A
- Mains mode efficiency: Mains Mode Efficiency: 最高95 / 最高95.5 %
- Operating Temperature Range: 工作环境温度范围: 0～50 ℃
- ECO mode efficiency: ECO Mode Efficiency: 最高99 %
- Input power factor: Input Power Factor: ≥0.99
- Input frequency range: Input Frequency Range: 40～70 Hz
- Front and rear installation clearance: Installation Ventilation Clearance: 前后最小200；后方示意间距500 mm
- Output voltage: 标称直流输出电压: 单相：220 / 230 / 240；三相：380 / 400 / 415 Vac
- UPS Topology: UPS Topology: 在线式高频双变换，正弦波输出，全数字控制
- Earth leakage current: Earth Leakage Current: 3.5～100 mA
- Input voltage range: 交流输入电压: 相电压：220 / 230 / 240；线电压：380 / 400 / 415 Vac
- relative humidity: Relative Humidity: 5～95 %RH
- Parallel Capacity and Redundancy: Parallel Capacity and Redundancy: N + X，1 ≤ N + X ≤ 3，X = 0或1；最高2 + 1冗余 台
- Dimensions: 物理结构外形尺寸: 160 × 400 × 350；160 × 500 × 420；160 × 530 × 420 mm
- Rated battery voltage: Rated Battery Voltage: 192～240 Vdc
- Display languages: Display Languages: 中文、英文
- Rated input frequency: Rated Input Frequency: 50 / 60 Hz
- Installation method: Installation Method: 建议落地安装，安装于混凝土或其他不燃表面
- ECO Mode Applicable Configuration: ECO Mode Applicable Configuration: 单机且配置外部电池；旁路正常时由旁路供电，旁路异常时由逆变器供电
- Operating altitude: Operating Altitude: ≤2000 m
- ECO Voltage Range: ECO Voltage Range: ±5 / ±10 / ±15；默认±10 %
- Communication interface: Communication Interfaces: 智能卡接口、干接点、RS232、RS485
- ECO Frequency Range: ECO Frequency Range: ±1 / ±2 / ±3；默认±3 Hz
- Battery cold start: Battery Cold Start: 支持
- Modbus address range: Modbus Address Range: 1～128；默认1
- Shared Battery Full-Load Runtime: Shared Battery Full-Load Runtime: 2～3 min
- Dynamic Response Recovery Time: Dynamic Response Recovery Time: 60 / 40 ms
- Dry contact port count: Dry Contact Port Quantity: 3个端口，共6针；标识REPO、1、2
- Control functions: Control Functions: 开机、关机、转旁路、告警静音、手动电池测试、故障清除、定时开关机
- Recommended Minimum Battery Modules: Recommended Minimum Battery Modules: 10 kVA：至少2组；20 kVA：至少4组
- Bypass Voltage Upper Limit: Bypass Voltage Upper Limit: +10 / +15 / +20；默认+20 %
- Bypass Voltage Lower Limit: Bypass Voltage Lower Limit: -10 / -20 / -30 / -40；默认-40 %
- Bypass Frequency Range: Bypass Frequency Range: ±5 / ±10；默认±10 Hz
- Battery String Quantity: Battery String Quantity: 16 / 18 / 20；默认16 块
- Battery Backup Time: Battery Backup Time: 6.0 / 7.5 / 9.0 / 11.0 / 14.5 / 19.5 / 29.0 / 48.0 / 100.0 min
- Battery Equalize Charge: Battery Equalize Charge: 可启用或禁用；默认禁用
- Battery Capacity Setting Range: Battery Capacity Setting Range: 7～3000 Ah
- Battery Module Expansion: Battery Module Expansion: 建议扩展6个电池模块；15 / 20 kVA每次至少增加2个模块
- Battery Type: Battery Type: 密封免维护铅酸电池，12 V / 9 Ah
- Battery Auto-Test Interval: Battery Auto-Test Interval: 禁用 / 8 / 12 / 16 / 20 / 26；默认禁用 周
- Output Voltage THD: Output Voltage THD: \<2 %
- Output Voltage Setting: Output Voltage Setting: 220 / 230 / 240；默认220 V
- Output Current Crest Factor: Output Current Crest Factor: 3:1
- Output Overload Capacity: Output Overload Capacity: 105%～125%：10 min；125%～150%：1 min；150%：200 ms
- Output Frequency Sync Range: Output Frequency Sync Range: 额定频率±3；可设置±0.5～±5 Hz
- Output Frequency Setting: Output Frequency Setting: 自动频率且允许旁路；自动频率且禁止旁路；50 Hz且禁止旁路；60 Hz且禁止旁路
- Output Frequency Slew Rate: Output Frequency Slew Rate: 默认0.5；可设置0.2 / 0.5 / 1 Hz/s
- Main and Bypass Backfeed Protection: Main and Bypass Backfeed Protection: 具备
- Low Battery Warning Time: Low Battery Warning Time: 2～30；默认2 min
- Protection and Alarm Monitoring: Protection and Alarm Monitoring: 输出短路、旁路反灌、输入中性线缺失、输入异常、整流器过载、逆变器过载、旁路过流、系统过温、风扇故障；电池反接、低电量、电压异常、缺失、测试失败、过温及放电终止关机；内部通信及整流器、DC/DC、直流母线、充电器、辅助电源、逆变器故障；关机状态输出带电、逆变继电器粘连、中性线对地异常；并机通信、电缆、台数、过载、冗余丢失、均流及设置不一致监测；REPO及关机输入监测
- Noise Level: Noise Level: \<55 / \<58 dB
- Storage Temperature: Storage Temperature: -40～+70 ℃
- Conditional Short-Circuit Current Rating: Conditional Short-Circuit Current Rating: 10 kA
- Battery Discharge Protection Time: Battery Discharge Protection Time: 1～4320；默认4320 min
- Battery Over-Temperature Alarm Threshold: Battery Over-Temperature Alarm Threshold: 40～60；默认50 ℃
- Battery Ambient Temperature: Battery Ambient Temperature: 15～25；标准工作温度20 ℃
- Emergency Power Off Function: Emergency Power Off Function: REPO立即关闭整流器、逆变器、逆变及旁路输出、充电与放电
- Expected Fan Life: Expected Fan Life: 20000～40000 h
- Display: Display: 彩色LCD，320 × 240点阵；支持输入、输出、负载、电池、告警及历史记录显示
- Energy Saving Modes: Energy Saving Modes: ECO供电模式、智能休眠模式
- Operating Modes: Operating Modes: 正常、旁路、电池、ECO、故障、维护旁路
- LBS Role Setting: LBS Role Setting: 禁用、主机、从机；默认禁用
- RDU-SIC Network Management: RDU-SIC Network Management: IRM / 1-Wire温度、温湿度及干接点传感器接入；告警记录、Trap、电子邮件、短信；Web、SNMP NMS、TCP/IP RDU-Manager、Nform Velocity Server监控及Network Shutdown集成
- REPO Interface Supply: REPO Interface Supply: 5 Vdc / 100 mA
- SIC Network Management: SIC Network Management: TCP/IP及Internet远程监控、计算机安全关机；扩展网络接口最多级联8个温湿度传感器
- UNITY-DP Communication Protocols: UNITY-DP Communication Protocols: Web、SNMP、Modbus、BACnet、YDN23
- AC Distribution Compatibility: AC Distribution Compatibility: 三相五线A / B / C / N / PE；TN、TT、IT系统
- Dual Bus Synchronization: Dual Bus Synchronization: 支持LBS；两套独立单机或并机系统组成主从系统；正常和/或旁路运行
- Rear Panel Ports: Rear Panel Ports: Intellislot、REPO、干接点、多功能接口、RS232、交流输入、电池输入、交流输出；部分面板另有并机接口
- Auto Restart on Mains Recovery: Auto Restart on Mains Recovery: 可启用或禁用；默认启用
- Dry Contact Rating: Dry Contact Rating: 125 Vdc / 0.5 A；30 Vdc / 1 A
- Dry Contact Input Functions: Dry Contact Input Functions: 电池模式关机、任意模式关机、维护模式；默认维护模式
- Dry Contact Output Functions: Dry Contact Output Functions: 低电池、使用电池、使用旁路、UPS故障
- Parallel Compatibility Conditions: Parallel Compatibility Conditions: 同容量、同市电电源、公共输出母线、相同参数设置
- Parallel Function: Parallel Function: 环形通信冗余；正常与旁路无缝切换；过载消除后自动返回；各机LCD可查询系统总负载
- Parallel Communication Cable Quantity: Parallel Communication Cable Quantity: 1 + 1系统：2根；2 + 1系统：3根
- Recommended Battery Cable Length: Recommended Battery Cable Length: ≤3 m
- Control Interface and Protocol: Control Interface and Protocol: 标准RJ45；Modbus / Jbus，或Vertiv温度、温湿度传感器
- Smart Card Compatibility: Smart Card Compatibility: SIC、RDU-SIC、RS485、UNITY-DP
- Battery Sharing Capability: Battery Sharing Capability: 15 / 20 kVA可共享电池串或使用独立电池串；6 / 10 kVA仅可使用独立电池串
- Power Terminal Configuration: Power Terminal Configuration: 输入L / N / PE；输出L / N / PE；电池BAT+ / BAT- / PE
- Auto Restart Delay: Auto Restart Delay: 0～999；默认10 s
- Input/Output Phase Configuration: Input/Output Phase Configuration: 单进单出或三进单出
- Cooling Method: Cooling Method: 内置风扇强制风冷，前进风、后出风
- Net Weight: Net Weight: 10.9 / 16.10 / 23.5 kg
- Mains to Battery Transfer Time: Mains to Battery Transfer Time: 0 ms
- Inverter to Bypass Transfer Time: Inverter to Bypass Transfer Time: ≤0 ms

## Frequently asked questions

### How do I choose the right Liebert GXE2 for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert GXE2 compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Liebert GXE2?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Liebert GXE2?

Yes. RICEWIND supplies Liebert GXE2 from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert GXE2?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Liebert GXE2.

### Does RICEWIND ship Liebert GXE2 internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### Does the Vertiv Liebert GXE2 support live hot-swapping in field operations?

Yes, Vertiv Liebert GXE2 is engineered with full hardware-level hot-plug protection, allowing live module insertion and extraction without interrupting critical site loads.

### How can this unit integrate into third-party DCIM or network management software?

It features native RS485/CAN/Ethernet interfaces supporting standard SNMP v3 and Modbus protocols, facilitating direct plug-and-play integration into centralized management platforms.

### What protection measures engage during over-voltage or thermal stress events?

The unit deploys multi-tier protection circuits: automatic lock-out on severe AC input surge/over-voltage with auto-recovery, and smart fan speed ramp-up with thermal derating under high ambient heat.

### What are the recommended routine maintenance practices for optimum longevity?

We recommend quarterly air filter dusting, semi-annual busbar torque and voltage calibration checks, and reviewing firmware telemetry logs via the management interface.

Content updated: 2026-09-16T06:29:13.790Z