# Vertiv Liebert GXE2 10kVA High Power Density Tower Online UPS (10kVA/9kW)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-liebert-gxe2-10kva

Model: Vertiv Liebert GXE2 10kVA

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What this product is

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What problem it solves

Mitigates power outage risks, suppresses severe grid voltage fluctuations and transient harmonics, and ensures zero interruption to downstream operations.

## Who and where it is for

Mission-critical communications infrastructure, industrial automated manufacturing cells, edge computing nodes, and distributed enterprise data centers.

## Core advantages

- True online double-conversion topology providing 0ms transfer time to isolate mains surges, sags, and harmonic distortions
- High output power factor (PF up to 0.9-1.0) delivering maximum active power capacity for high-density IT server loads
- Dual DSP digital processor control achieving over 95% operating efficiency and up to 99% in ECO mode
- Intelligent battery management featuring automated boost/float switching and scheduled self-test routines

## Applications

- Enterprise and cloud data center core networking suites, server clusters, and SAN storage arrays
- Financial banking transactions, securities clearing systems, and trading floor mission-critical IT
- Healthcare medical imaging suites (MRI, CT scanners) and critical intensive care instrumentation
- Industrial automation production lines, robotic workcells, and supervisory PLC control systems

## Technical specifications

- Output Voltage & Regulation Accuracy: 220VDC (176V ~ 286V)
- Management & Communication Interface: Management & Communication Interface
- Battery Storage Architecture: 192VDC (16 × 12V)
- Form Factor & Dimensions (HxWxD): 580 × 225 × 430 mm
- Cooling Topology & Airflow Management: Cooling Topology & Airflow Management
- Rated capacity: 10kVA / 9kW
- Transfer Time & Dynamic Response: 0 ms
- Input voltage range: Input Voltage Operating Range VAC
- Operating temperature: Operating Temperature Range °C

## Frequently asked questions

### How do I choose the right Vertiv Liebert GXE2 10kVA for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Vertiv Liebert GXE2 10kVA compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Vertiv Liebert GXE2 10kVA?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Vertiv Liebert GXE2 10kVA?

Yes. RICEWIND supplies Vertiv Liebert GXE2 10kVA from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Vertiv Liebert GXE2 10kVA?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Vertiv Liebert GXE2 10kVA.

### Does RICEWIND ship Vertiv Liebert GXE2 10kVA internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### How to resolve airflow obstruction alarm on Vertiv Liebert GXE2 10kVA in dusty environments?

Remove front dust filters, clean with dry compressed air, verify tachometer wiring connectors on fans, and clear heatsink channel debris to clear the fault.

### What are the diagnostic steps when Vertiv Liebert GXE2 10kVA triggers DC bus overvoltage protection?

Disconnect AC input, measure static open-circuit battery voltage, check for unbalanced cells causing elevated float voltage, and verify boost charge voltage parameters.

### How to execute a comprehensive hardware and firmware reset on Vertiv Liebert GXE2 10kVA following EMI events?

Isolate AC and battery breakers, hold the reset/mute button for 15 seconds to discharge residual capacitance, and recalibrate system status registers via service mode.

### What are the primary causes for communication packet loss or offline alarms on Vertiv Liebert GXE2 10kVA?

Commonly caused by ungrounded RS485 cable shielding, missing 120-ohm bus termination resistors, or baud rate/address conflicts on the multidrop loop.

Content updated: 2026-09-15T13:59:46.789Z