# Vertiv Liebert DME12MCP5 Precision Air Conditioner 12.5kW 380V-400V 3Ph (800×500×1950mm)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-liebert-dme12mcp5

Model: Liebert DME12MCP5 Precision Air Conditioner

The Vertiv Liebert DME12MCP5 is a high-reliability direct expansion (DX) air-cooled precision air conditioner engineered for mission-critical IT infrastructure, featuring high airflow, low enthalpy difference cooling, an SHR ≥ 0.90, and an electronically commutated (EC) backward-curved centrifugal fan for continuous 24/7/365 thermal regulation.

## What this product is

The Vertiv Liebert DME12MCP5 is a high-reliability direct expansion (DX) air-cooled precision air conditioner engineered for mission-critical IT infrastructure, featuring high airflow, low enthalpy difference cooling, an SHR ≥ 0.90, and an electronically commutated (EC) backward-curved centrifugal fan for continuous 24/7/365 thermal regulation.

## What problem it solves

The Vertiv Liebert DME12MCP5 indoor unit incorporates a compact footprint of 800×500 mm with complete front-access serviceability, specifically designed for enterprise branch server rooms, telecom base stations, and electrical control rooms. Engineered with eco-friendly R410A refrigerant, the system delivers a nominal cooling capacity of 12.5 kW, effectively minimizing unneeded dehumidification and latent energy waste.

The mechanical architecture integrates a continuously variable EC centrifugal fan paired with an industrial-grade scroll compressor, modulating airflow in real-time according to thermal loads to drive down fan power consumption. Electrically, it accepts wide-input 380V/400V 3-phase AC power with built-in phase-sequence auto-correction, thermal-magnetic overcurrent trip protection, and integrated transient surge suppression.

Thermal management is orchestrated by the proprietary Liebert microprocessor controller, featuring an onboard RS-485 interface running standard Modbus-RTU, with optional Web/SNMP interface cards for full DCIM integration. It enables teamworking of up to 32 units, supporting standby rotation, cascade activation, and fail-safe automated switchover under extreme industrial operating conditions.

## Who and where it is for

The Vertiv Liebert DME12MCP5 is a high-reliability direct expansion (DX) air-cooled precision air conditioner engineered for mission-critical IT infrastructure, featuring high airflow, low enthalpy difference cooling, an SHR ≥ 0.90, and an electronically commutated (EC) backward-curved centrifugal fan for continuous 24/7/365 thermal regulation.

## Core advantages

- 12.5kW nominal capacity with SHR ≥ 0.90 prevents unnecessary room dehumidification
- Modulating EC centrifugal fan reduces airflow parasitic power by more than 25%
- Ultra-compact 0.4 m² footprint with 100% front-access maintenance layout
- High CFM air circulation eliminates hot spots and maintains thermal uniformity
- Wide outdoor ambient operation capable of starting down to -15°C (opt. -35°C)
- Advanced microprocessor controller supports teamwork networking up to 32 units

## Applications

- Small-to-medium enterprise data centers and edge compute micro-racks
- Cellular 4G/5G core switching sites and microwave base transceiver stations
- Industrial PLC control cubicles and plant automation instrument rooms
- Railway signaling equipment shelters and transit control rooms
- Healthcare diagnostic facilities housing CT, MRI, and laboratory analyzers
- Substation relay automation control centers and smart grid telemetry rooms

## Technical specifications

- Cooling capacity: 12.5kW Nominal Sensible Cooling Capacity (High Airflow, Low Enthalpy)
- Sensible heat ratio: ≥ 0.90 (High SHF)
- Fan Drive Technology: Fully Digital Stepless Variable-Speed Inverter EC Centrifugal Fan
- AC Operating Voltage: 380V / 400V AC 3-Phase 50Hz/60Hz Auto-Sensing
- Refrigerant Type: R410A Eco-Friendly High-Pressure Refrigerant
- Controller System: Liebert Intelligent Microprocessor Controller with Diagnostics & Teamwork
- Operating Temperature Range: -15°C ~ +45°C (Low-Ambient Kit Supports down to -35°C)
- Dimensions: 800 × 500 × 1950 mm (Slim Footprint Full Front Maintenance)

## Frequently asked questions

### How do I choose the right Liebert DME12MCP5 Precision Air Conditioner for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DME12MCP5 Precision Air Conditioner compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DME12MCP5 Precision Air Conditioner?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DME12MCP5 Precision Air Conditioner?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DME12MCP5 Precision Air Conditioner?

Yes. RICEWIND supplies Liebert DME12MCP5 Precision Air Conditioner from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DME12MCP5 Precision Air Conditioner?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DME12MCP5 Precision Air Conditioner.

### What are the rated cooling capacity, SHR, and fan electrical efficiency of the Liebert DME12MCP5?

The unit delivers a 12.5 kW total cooling capacity with an SHR ≥ 0.90 and a nominal airflow of 3,300 m³/h. verifies that the factory-integrated backward-curved EC centrifugal fan exceeds 88% electrical-to-mechanical drive efficiency. Compared to legacy AC belt-driven fans, parasitic electrical consumption is reduced by 25% to 30%, maintaining small air enthalpy differentials without triggering parasitic reheating loads.

### What are the physical dimensions, mounting configuration, and airflow dynamics of the DME12MCP5?

The physical footprint measures 800 mm (W) × 500 mm (D) × 1950 mm (H), occupying 0.40 m² of floor space. supplies standard configurations supporting upflow or downflow distribution. All functional internal components—including the EC fan assembly, control boards, electronic expansion valve, and filter driers—are 100% accessible from the front panel, enabling zero-clearance side placement against 19-inch racks or perimeter walls.

### What electrical and ambient protection mechanisms safeguard the unit against volatile grid and extreme weather conditions?

The electrical system operates on 380V/400V AC 3-phase 50/60Hz with a ±15% voltage tolerance, featuring integrated phase-reversal auto-correction, under/overvoltage lockouts, and Class C surge protection. units incorporate an outdoor condenser head pressure regulator with variable fan speed control, ensuring steady operation across -15°C to +45°C ambients, extendable down to -35°C when fitted with the low-ambient kit.

### How does the DME12MCP5 manage power-failure auto-restart, standby rotation, and operational redundancy?

The microprocessor integrates non-volatile EEPROM memory to retain operational setpoints across total power outages, executing a staggered auto-restart between 1 and 60 seconds upon power restoration to mitigate gen-set inrush current. units support CAN/RS-485 inter-unit networking for up to 32 units, enabling scheduled master-standby duty rotation and sub-3-second failover activation if an active unit reports a critical fault alarm.

### Which communication protocols are supported for integration into centralized DCIM and BMS platforms?

The system includes an onboard isolated RS-485 serial port natively executing the Modbus-RTU protocol. can integrate an optional Liebert IntelliSlot Web/SNMP communication card supporting IPv4/IPv6, SNMP v1/v2c/v3, HTTP/HTTPS, and BACnet-IP. This allows facilities personnel to remotely adjust temperature and humidity setpoints, query telemetry, and receive real-time traps for high pressure, water leak, and blower failure.

### What full-load factory quality inspections and export packing standards does execute for this unit?

mandates a 100% full-load thermal performance inspection, including a 3.0 MPa high-pressure nitrogen holding test for refrigerant circuits and 4-hour dynamic burn-in validating electrical parameters and EC fan vibration spectra. Every unit ships with an individualized QA sign-off sheet, arrives pre-pressurized with dry nitrogen, is sealed inside vacuumized moisture-barrier foil, and is anchored in an ISPM-15 compliant shock-damped timber crate.