# Vertiv Liebert DME12MCP5 Precision Data Center Air Conditioner (12.5kW Sensible Heat Ratio \>0.9)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-liebert-dme12mcp5-air-conditioner

Model: Liebert DME12MCP5

The Vertiv Liebert DME12MCP5 is a 12.5kW high sensible heat precision environmental control unit engineered for server rooms, telecom exchanges, and laboratories, offering 24/7 continuous duty with temperature and humidity control accuracy subject to verification for the exact configuration and manufacturer-specified conditions.

## What this product is

The Vertiv Liebert DME12MCP5 is a 12.5kW high sensible heat precision environmental control unit engineered for server rooms, telecom exchanges, and laboratories, offering 24/7 continuous duty with temperature and humidity control accuracy subject to verification for the exact configuration and manufacturer-specified conditions.

## What problem it solves

Resolves severe power grid instability, excessive OPEX energy dissipation, battery degradation, and cabinet thermal constraints.

## Who and where it is for

5G cellular cell sites, core telecom DC plants, data center critical power infrastructure, railway signaling, and industrial UPS.

## Core advantages

- \>0.90 Sensible Heat Ratio: Specifically tailored for dry IT server heat profiles, eliminating wasted dehumidification energy.
- Copeland Scroll Compressor: Minimal moving parts and smooth operation ensure legendary 24/7/365 operational reliability.
- Fan energy use: verify input power and any savings for the actual fan configuration, airflow, static pressure and comparison conditions; no universal savings percentage is specified.
- Complete Precision Stewardship: Seamlessly manages cooling, PTC heating, electrode humidification, and air filtration.

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Refrigeration Compressor: Copeland High-Efficiency Scroll Compressor
- Circulating Airflow Volume: 3200 m³/h (High Volume, Low Enthalpy)
- Microprocessor Controller: Liebert Microprocessor + Graphic LCD
- Rated Cooling Capacity: 12.5kW Precision Sensible Cooling
- Sensible Heat Ratio (SHR): \>0.90 (Optimized Server Heat Removal)
- Supply Air Fan Architecture: Electronically Commutated (EC) Centrifugal Fan
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)

## Frequently asked questions

### How do I choose the right Liebert DME12MCP5 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DME12MCP5 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DME12MCP5?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DME12MCP5?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DME12MCP5?

Yes. RICEWIND supplies Liebert DME12MCP5 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DME12MCP5?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DME12MCP5.

### Is the Liebert DME12MCP5 configured for upflow or downflow air distribution?

It is available in both top-plenum upflow and raised-floor downflow airflow configurations to match facility designs.

### Can this unit interface with building automation/DCIM platforms?

Yes. Standard RS485 Modbus-RTU telemetry outputs temperatures, humidity, refrigerant pressures, and active alarms.

### How should the operating temperature range be confirmed?

Confirm operating temperature limits, low-ambient options and capacity corrections against manufacturer documentation for the exact indoor unit, matched outdoor unit and configuration. Industrial components or protective coatings do not establish continuous full-load operation at extreme ambient temperatures.

Content updated: 2026-09-20T12:35:08.123Z
