# Vertiv Liebert GXE3 3kVA Rack/Tower Online Double-Conversion UPS (3kVA/2.7kW 2U)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-gxe3-3kva

Model: Vertiv GXE3 3kVA

The Vertiv GXE3 3kVA is an industrial-grade telecom power or datacenter infrastructure module engineered for maximum uptime, high energy efficiency, and mission-critical reliability.

## What this product is

A field-proven industrial hardware system providing clean regulated DC power, precision thermal management, or unified physical equipment housing.

## What problem it solves

Eliminates downtime from grid surges, thermal throttling, and power outages, ensuring continuous 24/7/365 availability.

## Who and where it is for

Telecom core switching sites, 5G wireless base stations, enterprise server rooms, and modular edge computing deployments.

## Core advantages

- Heavy-duty industrial grade components designed for 24/7/365 uninterrupted mission-critical operation
- Ultra-wide operating voltage tolerance to thrive in unstable utility grid conditions
- Fully digital DSP microprocessor control with factory-aligned diagnostic routines
- High-density modular architecture supporting hot-swappable zero-downtime maintenance

## Applications

- Cellular Towers & Core Facilities
- Industrial Automation Enclosures
- Railway Signaling Infrastructure
- Enterprise Edge Datacenter Racks

## Technical specifications

- Physical Dimensions & Mounting Format: 85 (2U) × 438 × 462 mm
- Rated System Output / Load Capacity: 3kVA / 2.7kW (PF 0.9)
- Efficiency & Performance Rating: ≥ 96.0%
- Cooling & Thermal Management: Cooling & Thermal Management
- Operating Ambient Temperature Window: Operating Ambient Temperature Window °C
- Telemetry Communication Bus Protocol: Telemetry Communication Bus Protocol
- Output Voltage Regulation & Ripple: 220VDC (176V ~ 286V)
- Operating Input Voltage Range: 120VAC ~ 288VAC Wide Grid Voltage Range
- Core Power Topology & Conversion Unit: 8x 12V Maintenance-Free VRLA Batteries

## Frequently asked questions

### How do I choose the right Vertiv GXE3 3kVA for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Vertiv GXE3 3kVA compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Vertiv GXE3 3kVA?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Vertiv GXE3 3kVA?

Yes. RICEWIND supplies Vertiv GXE3 3kVA from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Vertiv GXE3 3kVA?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Vertiv GXE3 3kVA.

### Does RICEWIND ship Vertiv GXE3 3kVA internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### How to troubleshoot excessive DC output voltage ripple on Vertiv GXE3 3kVA?

Disconnect module output, measure electrolytic filter capacitor ESR, inspect current-share busbar contact resistance for oxidation, and verify PWM switching clock synchronization.

### What is the diagnostic procedure when Vertiv GXE3 3kVA triggers AC input undervoltage lockout in unstable grids?

Monitor RMS line voltage with a power analyzer to verify dips below the 85VAC threshold; widen the undervoltage recovery hysteresis by 5V in the controller to prevent cycling.

### What are the root causes of multi-unit current-sharing imbalance (deviation \> 10%) on Vertiv GXE3 3kVA?

1. Open current-share bus wire or oxidized backplane connector pins. 2. Zero-drift on module internal voltage calibration pot. 3. Asymmetrical branch cabling impedance; reseat units and re-calibrate no-load voltage baseline.

### What is the procedure to recover offline telemetry communication on Vertiv GXE3 3kVA?

Measure differential bus lines to ground to verify no transceiver shorts exist, ensure 120-ohm bus termination is intact, and hot-swap the module to trigger dynamic address re-enumeration.

Content updated: 2026-09-16T01:38:03.992Z