# Vertiv EXS 0060kBCB01 Integrated True Online Industrial UPS (60kVA/54kW)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-exs-0060kbcb01

Model: Vertiv EXS 0060kBCB01

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What this product is

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What problem it solves

Eliminates downtime from grid surges, thermal throttling, and power outages, ensuring continuous 24/7/365 availability.

## Who and where it is for

Telecom core switching sites, 5G wireless base stations, enterprise server rooms, and modular edge computing deployments.

## Core advantages

- True online double-conversion topology providing 0ms transfer time to isolate mains surges, sags, and harmonic distortions
- High output power factor (PF up to 0.9-1.0) delivering maximum active power capacity for high-density IT server loads
- Dual DSP digital processor control achieving over 95% operating efficiency and up to 99% in ECO mode
- Intelligent battery management featuring automated boost/float switching and scheduled self-test routines

## Applications

- Enterprise and cloud data center core networking suites, server clusters, and SAN storage arrays
- Financial banking transactions, securities clearing systems, and trading floor mission-critical IT
- Healthcare medical imaging suites (MRI, CT scanners) and critical intensive care instrumentation
- Industrial automation production lines, robotic workcells, and supervisory PLC control systems

## Technical specifications

- Rated System Output / Load Capacity: 60kVA / 54kW (PF 0.9)
- Physical Dimensions & Mounting Format: 1600 × 600 × 850 mm
- Operating Input Voltage Range: 380VAC / 400VAC Three-Phase Four-Wire
- Output Voltage Regulation & Ripple: 380V / 400V / 415VAC (3-Phase 4-Wire Regulated)
- Cooling & Thermal Management: Cooling & Thermal Management
- Operating Ambient Temperature Window: Operating Ambient Temperature Window °C
- Telemetry Communication Bus Protocol: Telemetry Communication Bus Protocol
- Efficiency & Performance Rating: ≥ 96.0%
- Core Power Topology & Conversion Unit: Integrated Compact Enclosure with Internal Batteries & Bypass

## Frequently asked questions

### How do I choose the right Vertiv EXS 0060kBCB01 for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Vertiv EXS 0060kBCB01 compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Vertiv EXS 0060kBCB01?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Vertiv EXS 0060kBCB01?

Yes. RICEWIND supplies Vertiv EXS 0060kBCB01 from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Vertiv EXS 0060kBCB01?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Vertiv EXS 0060kBCB01.

### Does RICEWIND ship Vertiv EXS 0060kBCB01 internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### What are the root causes of multi-unit current-sharing imbalance (deviation \> 10%) on Vertiv EXS 0060kBCB01?

1. Open current-share bus wire or oxidized backplane connector pins. 2. Zero-drift on module internal voltage calibration pot. 3. Asymmetrical branch cabling impedance; reseat units and re-calibrate no-load voltage baseline.

### What is the procedure to recover offline telemetry communication on Vertiv EXS 0060kBCB01?

Measure differential bus lines to ground to verify no transceiver shorts exist, ensure 120-ohm bus termination is intact, and hot-swap the module to trigger dynamic address re-enumeration.

### How to troubleshoot excessive DC output voltage ripple on Vertiv EXS 0060kBCB01?

Disconnect module output, measure electrolytic filter capacitor ESR, inspect current-share busbar contact resistance for oxidation, and verify PWM switching clock synchronization.

### What is the diagnostic procedure when Vertiv EXS 0060kBCB01 triggers AC input undervoltage lockout in unstable grids?

Monitor RMS line voltage with a power analyzer to verify dips below the 85VAC threshold; widen the undervoltage recovery hysteresis by 5V in the controller to prevent cycling.

Content updated: 2026-09-16T01:38:06.819Z