The Vertiv ER22005S is a carrier-grade, high-reliability high-frequency switched-mode rectifier module engineered for electric utility substations, power plants, and industrial high-voltage DC operating power systems, delivering a rated output of 220V DC / 5A (1100W) across a 176V to 286V DC regulation window with three-phase 323V to 475V AC wide input capability.

## What this product is

The ER22005S is a standardized modular rack-mounted DC operating power converter designed for utility-grade protection and control panels. It integrates three-phase passive power factor conditioning, high-frequency isolation transformers, dual closed-loop PWM regulation, and compliance with DL/T 781 and IEC 62368 standards. It interfaces via dual CAN/RS485 buses to supervisory controllers for automated equalized charging, float charging, and predictive health monitoring.

## What problem it solves

It eliminates vulnerability to phase imbalances, transient line surges, and sudden bus voltage dips caused by large trip-coil discharges in circuit breakers. It eliminates high ripple voltages that accelerate substation battery plate sulfation, while enabling continuous, zero-downtime hot-swap servicing during live operation without disrupting critical relay protection circuits.

## Who and where it is for

Tailored for 10kV to 500kV electrical substations, generation plants (thermal, hydro, nuclear), transmission grid switchyards, metro transit traction substations, and heavy industrial distribution panels powering DC trip coils, protection relays, and telemetry units.

## Core advantages

- Wide 3-phase AC input (323-475V) ensures stable operation under grid fluctuations.
- High-efficiency soft-switching topology and PFC achieve \>94.0% peak efficiency.
- Dual CAN/RS485 interfaces support intelligent charging and hot-swappable redundancy.
- Strictly complies with DL/T 781 standards for uninterrupted substation operation.

## Applications

- 110kV/220kV/500kV utility electrical substations powering 220V DC protection relay racks and operating switchgear
- Power plant control room excitation control systems, steam turbine trip circuits, and emergency DC lube oil pumps
- High-speed rail and urban metro traction substations supplying DC breaker tripping and SCADA RTU cabinets
- Industrial metallurgical and petrochemical primary 110kV distribution substations requiring resilient DC bus charging

## Technical specifications

- Maximum Output Current: 5A
- Rated Output Power: 1100W
- Rated Output Voltage: 220VDC (176V ~ 286V)
- AC Input Voltage: 323V AC ~ 475V AC (3-Phase Input)
- Maximum Efficiency: ≥ 94.0%
- Operating Temperature Range: -40°C ~ +75°C
- Cooling System: Natural Convection Cooling / Assist Fan
- Hot-Swappable Support: Yes (Live Hot-Pluggable / Plug-and-Play without Power Interruption)

## Frequently asked questions

### How do I select ER22005S for my power system?

Check output voltage, module power rating, efficiency class and compatibility with your existing rectifier shelf or controller. RICEWIND can verify fitment and propose the right quantity.

### Is ER22005S compatible with my existing system?

Compatibility depends on the rectifier shelf, controller and communication protocol. Send your current system model to RICEWIND and our engineers will confirm which modules fit.

### Does RICEWIND provide international shipping for ER22005S?

Yes. Power modules and systems are packed in anti-static, export-standard crates and shipped worldwide. Delivery time and freight options depend on stock and destination — contact RICEWIND for quotes and lead times.

### What warranty and technical support apply to ER22005S?

Warranty follows the manufacturer's policy for the specific equipment. RICEWIND supports testing guidance, replacement requests, spare parts and technical coordination per order terms.

### Does RICEWIND supply ER22005S from stock?

Yes. RICEWIND supplies ER22005S from verified stock with MOQ from 1 piece; in-stock units dispatch within 24-48 hours with global express air and sea freight.

### Is there a cross-reference or equivalent for ER22005S?

RICEWIND maintains a comprehensive cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta 48V telecom rectifiers. Contact us for the direct equivalent of ER22005S.

### What is the diagnosis procedure when the ER22005S front panel displays Output Overvoltage (OVP) with a solid red LED lockup?

The ER22005S incorporates a hardware-latched overvoltage protection circuit triggered between 290V and 320V DC. First, switch off the AC branch breaker and unlatch the module slightly from the chassis to completely de-energize it. Measure the DC bus to confirm that an external charger or battery float error is not back-feeding high voltage. If external voltage is nominal, allow internal capacitors to bleed down for 30 seconds, re-seat the module, and re-apply power. If the module instantly locks out again on open circuit, an internal voltage sensing optocoupler or power stage failure has occurred, requiring board-level repair.

### How does the ER22005S react under input phase loss or extreme three-phase grid voltage unbalance?

The unit continuously monitors phase balance and RMS voltages. If input voltage drops below 323V AC or a phase is lost entirely, the input monitoring circuit illuminates the yellow warning indicator and commands the DSP to initiate thermal foldback or controlled soft shutdown. This inhibits the PWM switching stage, preventing catastrophic overcurrent avalanche in primary MOSFETs/IGBTs. When balanced three-phase power within 323V~475V AC returns, the rectifier automatically clears the fault and restarts seamlessly.

### What corrective actions should be taken if parallel modules demonstrate active current-sharing imbalance exceeding 10%?

Verify that the central supervisory controller (e.g., PSM or EDU series) is transmitting identical float/boost voltage targets to each module address over CAN/RS485. Inspect the module backplane blind-mate connector pins for physical damage, oxidation, or loose connections on the analog current-share bus lines. Check that the open-circuit output voltages of all parallel modules are calibrated to within 0.5V of each other using internal trim parameters. Recalibrate any module whose internal current sensing amplifier exhibits drift.

### Can the ER22005S be safely hot-swapped while the substation DC bus is energized?

Yes. The ER22005S uses gold-plated blind-mate connectors with staged pin lengths ensuring Protective Earth (PE) mates first, followed by the DC and AC power pins, and finally the signal/CAN communication pins. To hot-swap safely: loosen the front-panel captive thumbscrews, firmly pull the ejector latch straight out to decouple the rear blind-mate connection, wait 3 minutes before handling internal components, and insert the replacement unit steadily until fully seated before tightening the mechanical locking screws.