# Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure 731 / R48-2900U Rectifiers 300A -48V DC IP55)

RICEWIND · Vertiv

https://ricewind.com/en/products/vertiv-21m-outdoor-cabinet-netsure

Model: Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure)

The Vertiv 2.1m Outdoor Telecom Power Cabinet is a carrier-grade, all-weather integrated infrastructure unit designed for remote macro base stations and harsh industrial sites. Incorporating the NetSure 731 subrack with R48-2900U rectifiers, it delivers up to 300A continuous -48V DC power with heavy-duty thermal insulation.

## What this product is

The Vertiv 2.1m Outdoor Telecom Power Cabinet is a carrier-grade, all-weather integrated infrastructure unit designed for remote macro base stations and harsh industrial sites. Incorporating the NetSure 731 subrack with R48-2900U rectifiers, it delivers up to 300A continuous -48V DC power with heavy-duty thermal insulation.

## What problem it solves

The Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure) provides an integrated, resilient power platform engineered for critical mission field deployments. With external dimensions of 950 × 900 × 2100 mm, the enclosure is fabricated from double-wall galvanized steel with internal thermal insulation, achieving an IP55 ingress protection rating that shields internal components from UV radiation, heavy dust, driving rain, and corrosive coastal salt spray. Inside, the platform houses a modular NetSure 731 DC power distribution system capable of accommodating multiple hot-swappable R48-2900U rectifiers delivering up to 300A with peak power conversion efficiency exceeding 96%.

The electrical distribution subsystem provides rigorous circuit safety, featuring integrated busbars with Load Low Voltage Disconnect (LLVD) and Battery Low Voltage Disconnect (BLVD) protections to prevent battery over-discharge and sustain mission-critical telecommunication loads. Thermal management is sustained via door-mounted intelligent industrial heat exchangers or air conditioning units, maintaining the segregated electronics and battery bays within safe thresholds from -40°C to +55°C. Managed by an advanced supervisory unit, the cabinet supports CAN/RS485 internal telemetry and interfaces with remote network operations centers via SNMP, Modbus, and Web-based GUIs.

## Who and where it is for

The Vertiv 2.1m Outdoor Telecom Power Cabinet is a carrier-grade, all-weather integrated infrastructure unit designed for remote macro base stations and harsh industrial sites. Incorporating the NetSure 731 subrack with R48-2900U rectifiers, it delivers up to 300A continuous -48V DC power with heavy-duty thermal insulation.

## Core advantages

- Integrated NetSure 731 subrack delivering up to 300A DC output
- R48-2900U rectifier modules achieve peak energy efficiency \>96%
- Heavy-duty double-wall steel enclosure certified to IP55 rating
- Door-mounted industrial AC cooling operable from -40°C to +55°C
- Integrated LLVD and BLVD dual-stage disconnect battery protection
- Supports SNMP, Modbus, and Web protocols for full remote monitoring

## Applications

- Off-grid and grid-connected 4G/5G macro cell telecom sites
- Oil and gas pipeline remote surveillance and block valve telemetry
- Rail transit signaling relay stations and trackside communications
- Maritime port terminals and coastal industrial wireless networks
- Smart grid electric utility substation perimeter communication hubs
- Border surveillance and meteorological field observation radar stations

## Technical specifications

- Cabinet Physical Height: 2.1m Carrier-Grade Heavy-Duty Outdoor Integrated Power Cabinet
- Built-in Power Subsystem: NetSure 731 Subrack with R48-2900U High-Reliability Rectifiers
- Total DC Distribution Capacity: 300A High-Capacity DC Busbars with Dual-Stage LLVD/BLVD Disconnect
- Thermal Management Architecture: Double-Wall Insulated Doors + Door-Mounted Industrial Heat Exchanger
- Protection Rating: IP55 Anti-Corrosion Powder Coating Resistant to UV, Acid Rain & Salt Spray
- Internal Battery Storage Space: Dedicated Battery Compartment for Multi-String Gel or LiFePO4 Batteries
- Physical Dimensions: 950 × 900 × 2100 mm
- Operating Temperature Range: -40°C ~ +55°C

## Frequently asked questions

### Is Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure) compatible with existing batteries, generators, and rectifiers?

Compatibility depends on DC bus voltage, telemetry protocols, and mechanical form factors. Describe your existing site setup and RICEWIND engineers can verify integration feasibility before you order.

### How is Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure) delivered? Does RICEWIND provide international shipping?

Power systems are packed in heavy-duty export-standard wooden crates for sea or air transport. RICEWIND ships worldwide — contact us to confirm inventory, freight options, and delivery schedules.

### What warranty and engineering support are available for Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure)?

Warranty follows the manufacturer policy for the specific configuration. RICEWIND supports wiring schematics, remote commissioning guidance, spare parts, and engineer-level technical assistance.

### Does RICEWIND supply Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure)?

Yes. RICEWIND supplies Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure) with MOQ from 1 system; in-stock units dispatch within 24-48 hours with global logistics coverage.

### Is there a cross-reference or equivalent replacement for Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure)?

RICEWIND maintains a cross-reference matrix covering Huawei, Vertiv, Eltek, and ZTE telecom power systems. Contact us for direct equivalents and expansion options for Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure).

### How do I plan and configure Vertiv 2.1m Outdoor Telecom Power Cabinet (NetSure) for my telecom site?

Consider total DC load, N+1 redundancy, battery autonomy backup time, surge protection, and cabinet footprint. Share your project requirements with RICEWIND and we will propose a matched configuration.

### What are the core electrical power ratings and conversion efficiency figures of this 2.1m power cabinet?

The cabinet houses the NetSure 731 power system delivering up to 300A continuous -48V DC output, with rectifiers achieving a peak efficiency of 96.2%. Powered by Vertiv R48-2900U modules, the system operates across an AC input range of 85V to 290V at 45–65Hz, with DC output voltage precisely adjustable between -42V DC and -58V DC.

### How are the physical chassis dimensions, internal compartments, and thermal management mechanisms engineered?

The cabinet measures 950 × 900 × 2100 mm externally and incorporates segregated equipment and battery bays with standard 19-inch mounting rails. Thermal management relies on a door-mounted intelligent AC or heat exchanger providing 1500W to 2500W of cooling capacity, paired with double-wall insulated panels to keep internal temperatures stabilized under outdoor ambient conditions from -40°C to +55°C.

### What surge suppression, grid fluctuation resilience, and ingress protection ratings are incorporated?

The unit provides IP55 ingress protection and integrates a Class C telecom-grade Surge Protective Device (SPD) rated at 20kA nominal and 40kA maximum discharge current (8/20μs) on the AC input. The exterior features heavy-duty UV-resistant and anti-corrosion coating tested for 1000-hour salt spray resistance, while rectifiers withstand sustained 415V AC overvoltage without component failure.

### How is battery energy storage managed, and what is the operating logic of the LLVD/BLVD disconnects?

The dedicated battery compartment accommodates multiple strings of VRLA or LiFePO4 batteries managed via independent LLVD and BLVD hardware contactors. Upon prolonged grid failure, the LLVD contactor disconnects non-essential loads when battery voltage drops to a preset limit (e.g., -44V DC). If discharge continues to the critical cutoff threshold (e.g., -43.2V DC), the BLVD contactor isolates the batteries entirely to prevent irreversible cell damage.

### Which hardware communication buses and remote network management protocols does the controller support?

The controller provides one RJ45 Ethernet port, two RS485 serial ports, and an internal CAN bus, natively supporting SNMP v1/v2c/v3, Modbus RTU/TCP, and HTTPS Web management. Operators can remotely capture individual rectifier currents, AC grid metrics, and environmental sensor telemetry, as well as configure float/boost charging parameters without on-site intervention.

### What load-bank quality inspection and export packaging standards does implement before dispatch?

subjects every cabinet to a mandatory 4-hour dynamic burn-in test under a 100% rated capacity (300A) resistive load bank, generating an authenticated report detailing thermal curves, insulation resistance, and efficiency metrics. For export transit, cabinets are vacuum-sealed inside IP55 moisture-barrier foil with shock-absorbing base brackets, and crated in heavy-duty ISPM-15 compliant non-fumigation solid wooden cases for ocean transport security.

Content updated: 2026-09-14T03:40:16.545Z