# Huawei R4850G6 Flagship Ultra-High Efficiency Rectifier (48V 50A 3000W)

RICEWIND · Huawei

https://ricewind.com/en/products/r4850g6

Model: R4850G6

Huawei R4850G6 is a flagship 3000W (-48V/50A) rectifier module featuring top-tier 96.8% efficiency, digital soft-switching topology, and ultra-low standby power.

## What this product is

Telecom-grade power infrastructure module designed for HUAWEI power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Achieves peak conversion efficiency over 97.5%, meeting Titanium-grade standards to significantly reduce operational power consumption.
- Wide AC input voltage range from 85VAC to 300VAC ensures robust grid adaptability and immunity to severe harmonic pollution.
- Compact 1U modular design (40.8×105×281mm) supporting hot-swapping and intelligent variable-speed fan cooling.
- Industrial-grade wide operating temperature from -40°C to +75°C ensures uninterrupted power for edge and core sites in extreme climates.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 85VAC ~ 300VAC (Nominal 220VAC)
- Conversion efficiency: ≥ 97.5%
- Cooling method: Forced-Air Cooling (Variable)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Dimensions: 40.8 (1U) × 105 × 281 mm
- Operating Temperature Range: -40°C ~ +75°C

## Frequently asked questions

### Which Huawei power subracks are compatible with the R4850G6, and can it be mixed or hot-swapped with legacy R4850G2/R4850N modules?

Engineered with a standard 1U form factor (40.8 × 105 × 281 mm), the R4850G6 natively fits Huawei ETP48100, ETP48200, and ETP48400 embedded power systems, as well as APM30H and ICC710 outdoor telecom enclosures. It integrates with SMU02B/SMU02C controllers over CAN bus, featuring live hot-swapping and active digital current sharing (imbalance \< ±5%). While physically and electrically backward-compatible for mixed operation with R4850G2 and R4850N units, group-level upgrades are strongly advised to unlock the full energy-saving benefits of the G6's 96.8% efficiency curve and deep-sleep management algorithms.

### What are the core electrical output and efficiency ratings of the Huawei R4850G6 rectifier, and how does it derate under low-voltage input?

The Huawei R4850G6 provides a nominal -48V DC output (adjustable from -42V DC to -58V DC), a rated current of 50A, and a rated capacity of 3000W, delivering a peak conversion efficiency of 96.8%, with PF ≥ 0.99 and THD ≤ 5%. Operating across a wide AC input range of 85VAC to 300VAC, it outputs full 3000W capacity between 176VAC and 300VAC. Between 85VAC and 176VAC, it implements a linear derating strategy (derating to approximately 1250W at 85VAC), preventing system brownouts during severe utility grid undervoltage conditions.

### What are the environmental durability, surge protection, and reliability specifications of the R4850G6 in harsh base station deployments?

The R4850G6 is built for challenging field conditions, operating from -40°C to +75°C (100% continuous output up to +55°C, linear derating up to +75°C) with cold start at -40°C. Cooling is handled by an internal stepless variable-speed fan coupled with a directed airflow path and conformal PCB coating to resist moisture, dust, and industrial pollution. Lightning and surge protection meets IEC 61000-4-5 standards with 4kV differential mode and 5kV common mode suppression on the AC port. It incorporates DC overvoltage latching, short-circuit self-recovery, and overtemperature protection, ensuring an MTBF exceeding 500,000 hours.

Content updated: 2026-09-11T00:57:37.095Z