# Huawei R4850G2 High-Efficiency Telecom Rectifier Module 3000W

RICEWIND · Huawei

https://ricewind.com/en/products/r4850g2

Model: R4850G2

The R4850G2 is a high-efficiency power system designed for telecommunication facilities and industrial infrastructure.

## What this product is

The Huawei R4850G2 is a high-efficiency digital rectifier module with an 85-290V AC input, 53.5V DC default output and 3000W output power from 176-290V AC, peak efficiency above 96%, hot-swap, CAN bus communication and parallel load sharing.

## What problem it solves

Resolves power conversion inefficiency, confined space constraints, and complex battery lifecycle management.

## Who and where it is for

Suitable for telecom base stations, data centers, edge computing aggregation nodes, and industrial DC applications.

## Core advantages

- Peak efficiency above 96%, with more than 95% at 230V AC and 30%-80% load, cutting energy loss and OPEX.
- Wide 85V AC to 290V AC input range for grids with large voltage swings.
- Compact 1U module (40.8 x 105 x 269 mm, under 2 kg) delivering up to 3000W when input is 176-290V AC.
- Built-in temperature-controlled fan, hot-swap support, CAN bus communication and LED alarms for centralised monitoring.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 85VAC ~ 290VAC (Rated 220VAC)
- Power Density & Power Consumption: High Power Density (2.54 W/cm³)
- Conversion efficiency: Peak \>96%; \>95% (230VAC, 30%~80% load)
- Cooling method: Built-in axial fan with intelligent temperature-controlled forced-air cooling
- Rated System Output Capacity: 3000W (derates linearly to 1250W below 176VAC)
- Nameplate output current: 50A
- DC output voltage range: -48VDC (adjustable -42V ~ -58V)
- Dimensions: 40.8mm × 105mm × 269mm (H×W×D)
- Operating Temperature Range: -25℃ ~ +75℃

## Frequently asked questions

### Which subracks are compatible with the R4850G2, and what are the rules and load-sharing mechanisms for mixed deployment?

The R4850G2 natively integrates into Huawei embedded DC systems including ETP48100, ETP48200, and ETP48400, as well as TP-series power cabinets (e.g., TP482000B), communicating with SMU02B/SMU02C controllers via internal CAN bus. Dimensioned at 40.8mm x 105mm x 269mm (1U), it is form-factor compatible with older legacy R4850G1 and R4850N units. The module features active digital current sharing with imbalance \<±5% between 50%–100% load. When co-deployed with standard-efficiency rectifiers, the monitoring unit (SMU) can execute an 'eco-cycling/efficiency-first' profile, prioritizing R4850G2 modules for primary baseloads to optimize thermal and power efficiency.

### What are the core electrical input/output parameters and conversion efficiency of the Huawei R4850G2 rectifier module?

The Huawei R4850G2 (SKU: HW-REC-R4850G2-50A) is a high-density 1U telecommunications power rectifier. It features an ultra-wide AC input range of 85VAC to 290VAC (linear derating applies below 176VAC) and delivers a rated output of 3000W when input exceeds 176VAC. DC output operates at nominal -48VDC (adjustable from -42VDC to -58VDC) with a rated continuous current of 50A (peak up to 50A). Employing soft-switching topologies and digital PFC, the unit achieves a rated efficiency ≥96% with a peak of 96%, PF ≥0.99, and THD ≤5%, substantially minimizing energy consumption in telecom sites and edge data hubs.

### What environmental tolerances, surge protection, and cooling safeguards are engineered into the Huawei R4850G2?

The R4850G2 is hardened for harsh telecommunication deployments, operating across -40°C to +75°C (linear power derating occurs above +55°C). Thermal management is governed by an integrated, variable-speed brushless DC axial fan featuring speed detection and fault alarms. Electrical robustness includes comprehensive AC under/overvoltage cutoff, continuous DC output short-circuit hiccup recovery, and over-temperature shutdown. Surge immunity meets 5kA differential/common mode (8/20μs) on AC ports, with high isolation ratings (3000VAC input-to-output, 1500VAC input-to-PE), certified under IEC/EN 60950-1 and UL60950-1, backed by an MTBF exceeding 500,000 hours.

Content updated: 2026-09-09T16:46:06.116Z