# Vertiv R48-5800A High Power Telecom Rectifier Module (48V 100A 5800W)

RICEWIND · Vertiv

https://ricewind.com/en/products/r48-5800a

Model: R48-5800A

Vertiv R48-5800A is a heavy-duty 5800W (-48V/100A peak) switch-mode rectifier module for central office telecom power plants like NetSure 801.

## What this product is

Telecom-grade power infrastructure module designed for VERTIV power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Ultra-wide 3-phase AC input (260V–530VAC) effectively mitigates grid pollution and ensures power continuity in extreme edge environments.
- Delivers a massive 5800W output with ≥93.0% high conversion efficiency, significantly reducing OPEX and carbon footprint for core networks.
- Extreme-temperature capability (-40°C to +65°C) paired with rear-exhaust stepless variable-speed cooling ensures high-reliability operation outdoors.
- Telecom-grade high-density architecture (2U, 88×244×380 mm) seamlessly integrates with VERTIV power platforms, supporting hot-swap and rapid deployment.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 260VAC ~ 530VAC (three-phase three-wire AC system)
- Cooling method: Rear-exhaust forced-air cooling with temperature-controlled stepless speed regulation
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- DC output voltage range: -48VDC (-42V ~ -58V)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Efficiency: ≥ 96.0%
- Dimensions: 132 (3U) × 85 × 287 mm
- Operating Temperature Range: -40°C ~ +75°C

## Frequently asked questions

### Which DC power systems are compatible with the R48-5800A, and how are parallel active current sharing and hot-swap handled?

The R48-5800A is natively designed for high-capacity Vertiv NetSure 801 (NC801) hub DC power plants. It supports true hot-swap capability via rear blind-mate connectors and communicates with M830D, M820D, or NCU supervisory controllers via CAN/RS485 bus. The module utilizes an active autonomous digital current-sharing bus, maintaining current imbalance below ±3%. It supports parallel scalability up to dozens of units (allowing system footprints from 1000A to 4000A+ per bay) with soft-start profiles, and cannot be intermixed with single-phase rectifiers like the R48-2900U or R48-3200e.

### What are the core electrical parameters and input/output characteristics of the Vertiv R48-5800A rectifier?

The Vertiv R48-5800A is a high-capacity, three-phase telecom rectifier designed for core exchange offices. It delivers a maximum output power of 5800W with a nominal -48V DC bus (adjustable from -42V DC to -58V DC) and up to 120A output current (nominal 100A peak). It operates on a three-phase three-wire AC input (delta connection, no neutral required) with a line-to-line voltage range of 260VAC to 530VAC (nominal 380-480VAC). Featuring active Power Factor Correction (PFC ≥ 0.99, THD ≤ 5%) and peak conversion efficiency \> 93.5%, it integrates internal hardware over-voltage clamp protection and active inrush current limiting.

### What reliability designs protect the module in extreme temperature, humidity, and harsh grid conditions?

The R48-5800A features a front-to-back forced air cooling design with an integrated temperature-controlled, stepless variable-speed fan. It operates across an ambient range of -40°C to +70°C, with linear thermal derating initiating above +45°C. The unit complies with IEC 61000-4-5 for surge immunity (2kV differential, 4kV common mode) and sustains overvoltages up to 530VAC without component breakdown. Its internal PCBs are treated with an industrial-grade conformal coating against humidity, salt spray, and dust, achieving an MTBF \> 450,000 hours for non-stop industrial and telecom duty.