Model: R48-3000e3

The Vertiv R48-3000e3 is an industrial high-efficiency switch-mode telecommunication rectifier module designed to convert standard AC input into regulated -48V DC power with up to 3000W output for telecom and enterprise mission-critical DC systems.

## What this product is

The R48-3000e3 utilizes modern digital signal processor (DSP) control and resonant conversion topology to transform single-phase AC input (85V to 300V) into highly stable -48V DC output. It incorporates active Power Factor Correction (PFC), integrated variable-speed cooling fans, CAN bus communications, and built-in protection against overvoltage, overtemperature, and load short-circuits.

## What problem it solves

It addresses energy wastage, thermal dissipation stress, and unexpected site outages in demanding grid environments by maximizing conversion efficiency up to 96.2% and providing full hot-swap redundancy for continuous 24/7 telecommunication operations.

## Who and where it is for

Compatible with Vertiv NetSure 500, 700, and 800 series DC power systems, outdoor telecom enclosures, wireless base station power plants, and edge computing DC architectures.

## Core advantages

- Peak conversion efficiency exceeding 96% to substantially reduce operating expenditures and site cooling demand
- Ultra-wide input AC voltage window (85VAC to 300VAC) for stable operation on unstable grids or generator supplies
- Compact 1U hot-pluggable physical design allowing seamless online maintenance and non-disruptive capacity scaling
- Operating temperature range from -40°C to +75°C with dynamic thermal management

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Input voltage range: 85 ~ 300 VAC
- Output voltage range: -48VDC (-42V ~ -58V) VDC
- Total harmonic distortion: ≤ 5 %
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Operating temperature range: -40 ~ +75°C
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Power factor: ≥ 0.99
- Cooling method: Forced-air cooling with intelligent speed control of the built-in fan

## Frequently asked questions

### Which subrack chassis systems are compatible with the Vertiv R48-3000e3, and does it support mixed paralleling with legacy modules?

The R48-3000e3 natively integrates into standard 19-inch and 21-inch NetSure power systems, including the NetSure 531, 731, and 801 platforms, governed by controllers like M530S, M830B, and NCU. It provides full hot-swap capability and high-speed CAN bus digital communication with active autonomous load sharing (unbalance margin \< ±5%). For infrastructure upgrades, it seamlessly replaces legacy units such as R48-3200 and R48-2900U. Mixed insertion with legacy modules within the same subrack is supported under firmware supervision, where the system dynamically apportions current based on individual rated capacity to safeguard critical N+1/N+2 redundancy.

### What are the core electrical conversion performance and operating specifications of the Vertiv R48-3000e3 rectifier module?

The Vertiv R48-3000e3 is an industrial-grade high-frequency telecom rectifier delivering up to 3000W rated output power, supplying a continuous current of 62.5A at nominal -48VDC with an adjustable output range of -42VDC to -58VDC. It supports an ultra-wide AC input range of 85VAC to 300VAC (full power output within 176VAC–290VAC, with linear power derating below 176VAC). Featuring a peak energy efficiency of 95.4%–96%, a power factor (PF) ≥ 0.99, and total harmonic distortion (THD) ≤ 5%, this module drastically cuts parasitic reactive power losses and HVAC cooling overhead in critical telecom and data center sites.

### How does the R48-3000e3 perform under extreme environmental temperatures and severe electrical grid disturbances?

Engineered for harsh deployments, the R48-3000e3 features an operating temperature range of -40°C to +75°C (100% full-load output from -40°C to +45°C, with smart thermal derating up to 75°C). It utilizes a pulse-width modulated (PWM) variable-speed fan coupled with an isolated thermal wind tunnel design to minimize dust ingestion. Electrical protections include robust surge withstand (2kV differential, 4kV common mode), input over/under-voltage auto-recovery, output over-voltage hardware latching, and continuous output short-circuit protection. With an MTBF exceeding 500,000 hours, it delivers mission-critical durability for remote, unmanned cell sites.

Content updated: 2026-09-09T16:01:33.546Z