# Vertiv Emerson R48-2900U Telecom Rectifier Module (48V 50A)

RICEWIND · Vertiv

https://ricewind.com/en/products/r48-2900u

Model: R48-2900U

The Vertiv R48-2900U is an industrial AC/DC switch-mode rectifier utilizing high-frequency soft-switching topology and active PFC to convert single-phase AC to filtered -48V DC power with autonomous load sharing.

## What this product is

Industrial-grade hot-swappable AC/DC rectifier designed for NetSure power systems and telecom DC plants.

## What problem it solves

Eliminates grid power anomalies and voltage drops, safeguarding sensitive base station transceivers with uninterrupted clean DC.

## Who and where it is for

Cellular macro base stations, enterprise DC power plants, remote microwave repeaters, and outdoor power cabinets.

## Core advantages

- Wide operating AC input range 85VAC to 290VAC
- Active Power Factor Correction with PF \> 0.99
- True hot-swappable architecture for zero-downtime maintenance
- Autonomous active current sharing across parallel modules

## Applications

- 4G/5G Wireless Macro Sites
- Broadband Optical Access Nodes
- Railway Signaling & Transit Comms
- Utility & Substation DC Plants

## Technical specifications

- AC input voltage range: 85 ~ 290 V AC
- Rated power: 2900W (50A @ 58V)
- Output voltage range: -48VDC (-42V ~ -58V)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Efficiency: ≥ 96.0%
- Dimensions: 132 × 85 × 287 mm
- Operating Temperature Range: -40 ~ +75°C

## Frequently asked questions

### Which subracks are compatible with R48-2900U, and does it support hot-swap and mixed-module current sharing?

Featuring a standard form factor of 132 × 85 × 287 mm, the R48-2900U is fully compatible with Vertiv/Emerson NetSure 501, NetSure 701, NetSure 502, NetSure 702 series power subracks and PS48-type power cabinets. It communicates natively via CAN bus with supervisory units including M500S, M522B, M830B, and NCU for true plug-and-play operation. The module supports live hot-swapping and active autonomous load sharing with a current-sharing unbalance of ≤ ±3%. While physically and functionally compatible for mixed deployment with high-efficiency counterparts (such as R48-2900e) during emergency field maintenance, pairing uniform rectifiers or applying controller-level group load balancing is recommended for optimal system efficiency.

### What are the core electrical input/output parameters and efficiency metrics of the Vertiv R48-2900U rectifier?

The Vertiv R48-2900U is engineered for high-availability telecom power architectures. It supports a wide single-phase AC input range of 85–290 V AC (full power delivery at 176–290 V AC, linear derating from 176 down to 85 V AC) with an input frequency of 45–65 Hz, active PFC ≥ 0.99, and THD ≤ 5%. It delivers a nominal -48 V DC output (adjustable from -42 V to -58 V DC), delivering up to 2900 W rated power and 50 A to 60.4 A continuous DC current depending on voltage setpoint. With a peak energy conversion efficiency exceeding 92%–93%, psophometric noise ≤ 2 mV, and peak-to-peak ripple ≤ 200 mV, it provides ultra-clean DC bus power ideal for sensitive 4G/5G RAN nodes and central office optical transmission hardware.

### What environmental tolerance and hardware protection capabilities are engineered into the R48-2900U?

The R48-2900U is built to rugged carrier-grade specifications, operating within an extreme temperature envelope of -40 °C to +75 °C (delivering full 2900 W output up to +45 °C, with intelligent thermal derating up to +75 °C). Forced front-to-rear air cooling is driven by a variable-speed brushless DC fan that modulates based on thermal telemetry, minimizing particulate ingress and acoustic noise. Critical electrical protections include AC overvoltage shutoff (\>290 V AC with auto-recovery hysteresis), input undervoltage protection, 2 kV differential / 4 kV common-mode surge immunity compliant with IEC 61000-4-5, output overvoltage latching, and continuous short-circuit protection, delivering an MTBF in excess of 400,000 hours.

Content updated: 2026-09-10T13:07:49.041Z