# Vertiv R48-2000e3 High Efficiency Telecom Rectifier Module (48V 2000W)

RICEWIND · Vertiv

https://ricewind.com/en/products/r48-2000e3

Model: R48-2000e3

The R48-2000e3 is a high-efficiency power system designed for telecommunication facilities and industrial infrastructure.

## What this product is

Vertiv R48-2000e3 High Efficiency Telecom Rectifier Module -48V 2000W features a modular architecture and high-reliability components for simplified maintenance and monitoring.

## What problem it solves

Resolves power conversion inefficiency, confined space constraints, and complex battery lifecycle management.

## Who and where it is for

Suitable for telecom base stations, data centers, edge computing aggregation nodes, and industrial DC applications.

## Core advantages

- Ultra-high conversion efficiency exceeding 96.2%, significantly reducing telecom operational expenditures and carbon footprints.
- Wide input voltage range from 85VAC to 300VAC ensures resilient performance in unstable or remote power grids.
- Robust operation across a wide temperature range of -40℃ to +75℃ with intelligent DC fan cooling for extreme environments.
- Hot-swappable modular architecture and smart remote management enable rapid deployment and precise battery maintenance.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- AC input voltage range: 85VAC ~ 300VAC
- Output voltage range: -48VDC (-42V ~ -58V)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Efficiency: ≥ 96.2%
- Dimensions: 132 × 85 × 287 mm
- Operating Temperature Range: -40°C ~ +75°C
- Cooling method: Front-to-rear air cooling with a temperature-controlled DC fan

## Frequently asked questions

### Which subrack systems are compatible with R48-2000e3, and does it support hot-swap mixing and autonomous current sharing?

The R48-2000e3 natively integrates into Vertiv NetSure 211, NetSure 501, and NetSure 701 power subracks with full hot-swap capability. It utilizes CAN-bus digital communication managed by M221S, M222S, NCU, or ACU+ supervisory controllers. Mechanically, it is backward-compatible with older R48-2000/R48-1800 slots. While digital active current sharing maintains current imbalance within \<±5%, mixing e3 high-efficiency units with legacy lower-efficiency modules is technically viable but engineering-recommended for group replacement to optimize thermal profiles and load distribution across rectifiers.

### What are the core electrical conversion metrics and derating characteristics of the Vertiv R48-2000e3 rectifier module?

The Vertiv R48-2000e3 is an ultra-high efficiency telecom rectifier rated at 2000W with a nominal -48VDC output (adjustable from -42VDC to -58VDC) and a maximum output current of 41.7A. It features a wide AC input range of 85VAC to 300VAC, providing full 2000W output between 176VAC and 300VAC, with linear power derating below 176VAC down to ~40% load capacity at 85VAC. It delivers a peak efficiency of ≥96.2%, power factor (PF) ≥0.99, and THD ≤5% from half to full load, fully complying with IEEE 519 standards and carrier-grade energy efficiency benchmarks.

### What protection mechanisms and reliability measures ensure R48-2000e3 operation under extreme grid and environmental conditions?

The R48-2000e3 is engineered for operating temperatures from -40°C to +75°C, delivering 100% non-derated power up to +55°C. Cooling is driven by a front-to-back variable-speed DC brushless fan governed by internal temperature sensors and load levels. Protection topologies include sustained AC overvoltage shutoff (\>305VAC with auto-recovery), dual-loop DC overvoltage shutdown, output short-circuit protection with auto-restart, and thermal shutdown. It meets IEC 61000-4-5 surge immunity (2kV differential / 4kV common mode), ensuring survival in remote base stations and unstable grid topologies.