# Vertiv Emerson R48-1000A Telecom Rectifier Module (48V 20A 1000W)

RICEWIND · Vertiv

https://ricewind.com/en/products/r48-1000a

Model: R48-1000A

The Vertiv R48-1000A is a high-reliability AC/DC switch-mode power supply featuring high-frequency soft-switching and active PFC to convert single-phase AC into stable -48V DC power with autonomous load sharing.

## What this product is

Compact hot-swappable AC/DC rectifier designed for Vertiv NetSure small-capacity power systems.

## What problem it solves

Provides clean regulated DC power for low-load transmission equipment under unstable rural grid conditions.

## Who and where it is for

Small-cell base stations, optical remote terminals, transit signaling boxes, and outdoor pole-mount cabinets.

## Core advantages

- Wide AC input range from 85VAC to 290VAC
- Active Power Factor Correction with PF \> 0.99
- Compact lightweight form factor with true hot-swappability
- Comprehensive protection including over-temp and short-circuit

## Applications

- Small-Cell Wireless Sites
- Optical Distribution Hubs
- Rail Traffic Signal Systems
- Utility SCADA Remote Nodes

## Technical specifications

- AC input voltage range: 85 ~ 290 V AC
- Rated power: 1000W (20.8A @ 48V)
- Output voltage range: -48VDC (-42V ~ -58V)
- Overall System Efficiency: Up to 96.2% (Gold Standard)
- Acoustic Noise: ≤ 55 dBA (at 25°C ambient load)
- Ingress Protection Rating: IP20 (Indoor Dust & Finger Proof)
- Dielectric Withstand Voltage: 3000VAC Input to Ground (\< 5mA)
- Efficiency: ≥ 96.0%
- Dimensions: 132 × 85 × 287 mm
- Operating Temperature Range: -40 ~ +75°C

## Frequently asked questions

### Which power subracks are compatible with the R48-1000A, and how do its hot-swap and active current sharing mechanisms operate?

With dimensions of 132 × 85 × 287 mm (standard 3U form factor), the R48-1000A natively integrates into Vertiv/Emerson NetSure 211, NetSure 212, and PS48120 compact DC power shelves. It features true live hot-swapping via blind-mate backplane connectors. Internal microcontrollers communicate with central supervisors (e.g., M221S, M222S) via CAN bus or RS485 for monitoring and control. Parallel modules utilize an autonomous active current sharing bus with an imbalance tolerance under ±3%. If any module fails or is extracted, remaining units autonomously assume the load within milliseconds without interrupting the DC bus.

### What are the core electrical performance and conversion efficiency specifications of the Vertiv R48-1000A rectifier module?

The Vertiv R48-1000A (SKU: VERTIV-REC-R48-1000A) is a telecom-grade switch-mode rectifier delivering a rated output of 1000W and 20A at -48V DC. It features a wide AC input range of 85V AC to 290V AC, supporting full 1000W output between 176V AC and 290V AC with linear derating down to 85V AC. The DC output is adjustable from -42V DC to -58V DC. Equipped with active Power Factor Correction (PFC), it achieves a power factor ≥0.99, THDi ≤5%, and peak conversion efficiency exceeding 92%, while maintaining low output ripple/noise (peak-to-peak ≤200mV, psophometric noise ≤2.0mV) in compliance with stringent telecom standards.

### How is the Vertiv R48-1000A engineered to withstand harsh telecom environments in terms of thermal limits and surge protection?

Engineered for harsh base stations and edge outdoor cabinets, the R48-1000A operates reliably over a temperature span of -40 °C to +75 °C (with intelligent dynamic derating starting above +45 °C). Forced-air cooling is provided by an integrated speed-controlled DC brushless fan with stall alarm telemetry. Protection features include AC input over/under-voltage cut-off with hysteresis, output over-voltage hardware clamp, cycle-by-cycle current limiting, and short-circuit self-recovery. Surge immunity meets IEC 61000-4-5 specifications (differential mode 2kV, common mode 4kV), achieving an MTBF exceeding 500,000 hours.