# Vertiv NetSure 731 A91-S2 Subrack Telecom DC Power System (-48V 300A 4U)

RICEWIND · Vertiv

https://ricewind.com/en/products/netsure-731-a91-s2

Model: NetSure 731 A91-S2

The Vertiv NetSure 731 A91-S2 is a high-density 19-inch 6U embedded telecom DC power system delivering up to 300A output, engineered for 4G/5G wireless sites, central offices, and edge computing nodes.

## What this product is

An integrated -48VDC power system comprising a rectifier subrack, AC/DC distribution assembly, dual Low Voltage Disconnect contactors, and an advanced M830B/NCU controller. It houses up to six high-efficiency rectifiers to convert fluctuating AC mains into clean, regulated DC power.

## What problem it solves

Eliminates site footprint constraints in tight telecom shelters, mitigates grid instability across 85-300VAC, and prevents catastrophic battery degradation through precision multi-stage low-voltage disconnection.

## Who and where it is for

5G outdoor base station enclosures, telecom aggregation nodes, edge computing rooms, enterprise core routing facilities, and industrial automation networks demanding robust -48V backup.

## Core advantages

- Peak energy efficiency of ≥96.0%, drastically lowering heat dissipation and site operating costs
- Ultra-wide input window (85VAC to 300VAC) guaranteeing operational resilience in poor grid regions
- Dual-stage LVD architecture (LLVD for shedding non-critical loads, BLVD for absolute battery discharge protection)
- Fully hot-swappable architecture across all rectifiers and control units for zero-downtime maintenance
- Comprehensive battery care algorithms including precision thermal compensation, automated boost/float management, and scheduled SOC testing

## Applications

- 4G/5G macro and micro base transceiver stations (BTS)
- FTTx optical line terminal (OLT) shelters and broadband aggregation sites
- Railway signaling, SCADA, and wayside communication power supplies
- Substation protection systems and enterprise data room DC distribution

## Technical specifications

- AC Input Voltage: 85VAC ~ 300VAC (Nominal 220VAC) VAC
- Smart Monitoring Controller: M830B / NCU Controller
- Cooling System Architecture: Intelligent temperature-controlled cooling
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Managed Rectifier Capacity: 4 Slots for R48-2900U Modules
- Rated DC Output Current: 300A (System Capacity 14.4kW)
- Peak Energy Efficiency: ≥96.0%
- Form Factor Dimensions (HxWxD): 177 (4U) × 482 × 360 mm
- Operating Temperature Range: -40°C ~ +65°C

## Frequently asked questions

### How do I choose the right NetSure 731 A91-S2 for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is NetSure 731 A91-S2 compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for NetSure 731 A91-S2?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for NetSure 731 A91-S2?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply NetSure 731 A91-S2?

Yes. RICEWIND supplies NetSure 731 A91-S2 with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for NetSure 731 A91-S2?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of NetSure 731 A91-S2.

### How should DC distribution output cables be sized for the NetSure 731 A91-S2 operating at full 300A load?

Cable sizing must satisfy both continuous ampacity and maximum permissible loop voltage drop standards. For -48VDC telecom infrastructure, the total two-way loop voltage drop must not exceed 0.5V. Using the cross-section formula S = (2 × L × I) / (γ × ΔU), where γ is copper conductivity (57 m/(Ω·mm²)), I = 300A, and ΔU = 0.5V: for a one-way run of L = 10 meters, S ≈ (2 × 10 × 300) / (57 × 0.5) ≈ 210.5 mm². Therefore, standard engineering practice dictates using two parallel 120 mm² or a single 240 mm² flame-retardant copper cable, derated according to ambient ambient temperature and duct bundling.

### What are the recommended voltage disconnect thresholds for LLVD and BLVD contactors in the NetSure 731 A91-S2?

For standard 24-cell VRLA lead-acid battery strings (2.0V/cell nominal), standard configuration on the M830B controller specifies: LLVD (Load Low Voltage Disconnect for non-critical loads) set to 45.0V (approx. 1.875V/cell), with reconnection at 49.0V–50.0V. BLVD (Battery Low Voltage Disconnect for critical loads and battery protection) should be configured to 43.2V (absolute 1.80V/cell cutoff limit), with reconnection at 51.0V. This staged approach sheds non-essential equipment first to prolong core transmission uptime, while preventing irreversible sulfation caused by deep battery discharge.

### How is the battery temperature compensation coefficient configured in the M830B, and what happens if the sensor fails?

At a 25°C reference temperature, standard float voltage is typically 53.5V (2.23V/cell for 24 cells). The M830B compensation coefficient is normally set to -3.0 mV/°C/cell (-72 mV/°C for the complete 48V string). As ambient battery temperature rises, the system lowers float voltage to prevent thermal runaway; when temperatures drop, it raises voltage to ensure 100% state of charge. If the temperature probe suffers an open/short circuit, the M830B triggers a MAJOR alarm, disables auto-boost charging, and defaults float voltage strictly to the nominal 25°C benchmark (53.5V) to protect the battery bank from uncontrolled overcharging.

### What is the acceptable current sharing unbalance between parallel R48-3000e3 rectifiers, and how is an imbalance diagnosed?

Within 50% to 100% load conditions, the current sharing imbalance across parallel R48-3000e3 rectifiers must remain below \<±5% of the rated output current. Troubleshooting steps: 1. Access the M830B web/local menu to inspect real-time module currents and identify any unit idling at 0A or pinned at 100%; 2. Check CAN bus communication status to rule out bus termination or address assignment conflicts; 3. Hot-unplug the suspect module to inspect rear backplane golden-finger connectors for bent pins, corrosion, or contamination; 4. If CAN communication is intact, verify actual output with an external clamp meter; internal current sense calibration drift requires module replacement.