# Vertiv NetSure 701 A41-S6 Subrack Telecom Switch-Mode Power System (-48V 400A 5U)

RICEWIND · Vertiv

https://ricewind.com/en/products/netsure-701-a41-s6

Model: NetSure 701 A41-S6

The Vertiv NetSure 701 A41-S6 is a 6U 19-inch rack-mounted -48VDC telecom-grade power system engineered for up to 400A output, integrating high-efficiency rectifier slots, AC/DC distribution, and an M530S/NCU controller.

## What this product is

An integrated subrack telecom power solution by Vertiv designed to supply robust, uninterrupted -48V direct current to critical network hardware. It consolidates AC utility distribution, rectifier shelves accommodating up to six hot-swappable e-series rectifiers, DC load distribution, and intelligent supervisory logic into a standard 6U chassis.

## What problem it solves

Eliminates footprint constraints in dense telecom shelters, minimizes inter-chassis cabling faults, mitigates severe grid surges via wide input voltage tolerance, and prevents catastrophic battery cell damage using configurable LLVD/BLVD isolation.

## Who and where it is for

Wireless macro base stations, central office broadband access aggregation, transmission hub sites, and critical industrial -48VDC control systems.

## Core advantages

- High-Density Integration: Compact 5U enclosure integrates AC/DC distribution and rectifier slots, saving valuable footprint.
- Ultra-Wide AC Input: Supports 85VAC to 300VAC input, perfectly adapting to unstable grid conditions and voltage fluctuations.
- High-Efficiency Power Output: Delivers up to 96.0% peak efficiency with a robust 400A (19.2kW) stable -48VDC output.
- Intelligent Battery Management: Advanced controller features precise temp-compensation and LLVD/BLVD protection to extend battery lifespan.

## Applications

- Telecom 4G/5G macro cellular base stations and distributed remote power sites
- Enterprise-grade cloud data center mission-critical -48V DC power distribution lineups
- Utility power grid dispatch centers and high-voltage substation DC switchgear rooms
- Railway transit signaling, automated train control, and communications equipment rooms

## Technical specifications

- Smart Monitoring Controller: M830B / NCU Controller
- AC Input Voltage: 85VAC ~ 300VAC (3-Phase 380V / 1-Phase 220V) VAC
- Cooling System Architecture: Forced Air Cooling
- Nominal Output Voltage: -48VDC (-42V ~ -58V) VDC
- Managed Rectifier Capacity: 4 Slots for R48-2900U / R48-3200e Modules
- Rated DC Output Current: 400A (System Capacity 19.2kW)
- Peak Energy Efficiency: ≥96.0%
- Form Factor Dimensions (HxWxD): 222 (5U) × 482 × 380 mm
- Operating Temperature Range: -40°C ~ +65°C

## Frequently asked questions

### How do I choose the right NetSure 701 A41-S6 for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is NetSure 701 A41-S6 compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for NetSure 701 A41-S6?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for NetSure 701 A41-S6?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply NetSure 701 A41-S6?

Yes. RICEWIND supplies NetSure 701 A41-S6 with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for NetSure 701 A41-S6?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of NetSure 701 A41-S6.

### How should DC output cable cross-sectional area be calculated for the NetSure 701 A41-S6 based on loop voltage drop constraints?

Telecom engineering standards typically limit total loop DC voltage drop to between 0.5V and 1.0V. The formula for copper cable cross-section is: S = (2 × L × I) / (γ × ΔU), where L is one-way cable length in meters, I is maximum branch circuit current in Amperes, γ is copper conductivity (typically 57 m/(Ω·mm²)), and ΔU is allowable loop voltage drop in Volts. Always round up the calculated value to the next standard metric gauge and verify the terminal lug physical accommodation and thermal ampacity limits.

### How should the Load Low Voltage Disconnect (LLVD) and Battery Low Voltage Disconnect (BLVD) thresholds and delay parameters be configured in the M530S controller?

For standard 24-cell VRLA lead-acid battery strings, standard baseline engineering configuration sets LLVD (non-priority load shedding) to 45.0VDC – 45.6VDC (approx. 1.88V – 1.90V/cell) with a 10-second filter delay. BLVD (battery total protection cut-off) is set to 43.2VDC – 44.0VDC (approx. 1.80V – 1.83V/cell) with a 5-second filter delay to prevent irreversible deep discharge. For Lithium (LiFePO4 15S/16S) chemistry, thresholds must align with BMS protocol parameters, typically setting BLVD to 44.0VDC for a 16-cell string.

### What is the operating mechanism of battery temperature compensation, and how should it be calibrated based on the physical battery environment?

Electrochemical battery kinetics accelerate at higher temperatures. As temperature rises, float voltage must decrease to prevent grid corrosion, gassing, and thermal runaway; as temperature falls, float voltage must rise to avoid undercharging. The M530S controller reads ambient/cell temperature via external NTC sensors and adjusts bus voltage. For standard 24-cell VRLA batteries, the standard coefficient is -3mV/°C/cell (-72mV/°C per 48V string) referenced to 25°C, with hard ceiling (e.g., 56.4V) and floor (e.g., 52.0V) clamps enabled. When using LiFePO4 batteries with onboard BMS, this controller temperature compensation function MUST be disabled.

### How does the autonomous active current sharing mechanism operate during parallel rectifier operation, and what factors should be inspected if significant current imbalance occurs?

Vertiv high-efficiency rectifiers (e.g., R48-3200e) utilize autonomous digital CAN-bus active current sharing. Rectifier DSPs exchange current metrics across the internal bus, continuously trimming PWM regulation loops to maintain load imbalance below ±3% of rated output. If severe imbalance or zero-output anomalies occur: 1) Inspect backplane CAN bus connectors for bent pins, cold solder joints, or high resistance; 2) Measure AC input terminal voltages to ensure low line voltage is not triggering thermal/input current derating; 3) Verify the controller is not broadcasting a forced restricted current-limit command to specific slots; 4) Reseat the rectifier to verify rear edge-connector engagement, or bench-test for faulted internal OR-ing output FETs.