# Vertiv NetSure 701 A41-S10 6U 19-Inch Rack-Mount (200A -48V DC Embedded Telecom Power System)

RICEWIND · Vertiv

https://ricewind.com/en/products/netsure-701-a41-s10

Model: NetSure 701 A41-S10

The Vertiv NetSure 701 A41-S10 is a highly integrated 6U 19-inch rack-mount -48V DC embedded power system delivering up to 200A output, engineered with 4 rectifier slots compatible with R48-2900U/R48-3200e modules, an M221S/M222S controller, and intelligent battery management for enterprise and carrier-grade infrastructure.

## What this product is

A standard 19-inch 6U integrated power subrack accommodating AC/DC distribution, intelligent monitoring, and 4 hot-swappable 50A telecom rectifier positions. It incorporates built-in lightning protection, battery breakers with Low Voltage Disconnect (LVD), and comprehensive remote telemetry ports.

## What problem it solves

Mitigates challenges of constrained cabinet space, unstable utility grids prone to deep sags and high voltage spikes, and premature battery degradation via dynamic thermal management and multi-stage battery disconnect controls.

## Who and where it is for

Telecom operators (4G/5G macro and micro base stations), microwave backbone nodes, railway signaling repeaters, utility substation automation, and enterprise edge data aggregation centers.

## Core advantages

- Compact 6U High Density: Full integration of AC/DC breakers, controller, and 4 rectifier bays within standard 19-inch footprints.
- High Gold Efficiency: Achieves ≥96% system conversion efficiency with wide 85V~300V AC operating threshold to survive severe grid fluctuations.
- Smart Battery Optimization: Features LLVD/BLVD protection, precision temperature compensation, and scheduled auto-equalize routines extending battery lifespans.
- Carrier-Grade Redundancy: N+1 parallel modular redundancy, hot-swappable active components, and robust CAN-bus digital control ensures continuous uptime.

## Applications

- 5G macro and small cell centralized DC power plants
- Wired optical access nodes (FTTH/GPON central offices)
- Long-haul microwave and optical fiber repeater stations
- Industrial SCADA communication terminals and IoT hubs

## Technical specifications

- System output capacity: 200A (-48V DC)
- Physical Form Factor: 19-Inch Rackmount
- System efficiency: ≥ 96%
- AC input voltage range: 85V AC ~ 300V AC (Nominal 220V AC)
- DC Distribution Branches: Input: 1×125A/2P + Output: 1×16A/1P + Battery: 2×125A
- Operating Temperature Range: -40°C to +65°C
- Rectifier Module Slots: 4 Slots
- System Monitoring Controller: M221S / M222S Intelligent Controller Unit

## Frequently asked questions

### How do I choose the right NetSure 701 A41-S10 for my system?

Verify host model, electrical ratings, interface types and protocol requirements. Share your system details with RICEWIND and we will compare compatible options across brands.

### Is NetSure 701 A41-S10 compatible with my existing equipment?

Compatibility depends on power input, pinout signals and rack mounting specifications. Our engineers can review interfaces and integration details before you order.

### Does RICEWIND provide international shipping for NetSure 701 A41-S10?

Yes. RICEWIND ships worldwide; freight options depend on destination, weight and urgency. Contact us for a shipping quote to your site.

### What warranty and after-sales support are available for NetSure 701 A41-S10?

Warranty follows the manufacturer policy for your region. RICEWIND provides technical documentation, firmware guidance and engineer-level assistance throughout the project.

### Does RICEWIND supply NetSure 701 A41-S10?

Yes. RICEWIND supplies NetSure 701 A41-S10 with MOQ from 1 unit; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for NetSure 701 A41-S10?

RICEWIND maintains a cross-reference database covering leading telecom and energy infrastructure brands. Contact us for the direct equivalent of NetSure 701 A41-S10.

### What are the electrical output limits, nominal efficiency, and input thresholds for the NetSure 701 A41-S10?

The system operates at a nominal -48V DC output (adjustable from -42V to -58V DC) with a maximum current rating of 200A. When fully equipped with four 50A rectifiers (such as R48-2900U or R48-3200e) across a 176V~300V AC input, total output delivers up to 12kW with a system peak efficiency ≥96%. At degraded AC input levels (85V~176V AC), the rectifiers transition into linear power derating mode to maintain uninterrupted operation without shutting down the DC bus.

### Which rectifier modules are supported, and do they enable hot-swapping and active load sharing?

The chassis natively supports Vertiv/Emerson R48-2900U, R48-3200e, and compatible e-series 50A 48V rectifiers. The system architecture uses an internal CAN bus to facilitate true plug-and-play hot-swapping and autonomous current sharing with imbalances held below ±3%. While emergency operations allow mixing module revisions, the M221S/M222S controller dynamically manages bus communication; standardized module deployment is recommended for optimal thermal and electrical performance.

### What are the operational environmental ratings, lightning protection, and surge withstand metrics?

Engineered to telco harsh-environment standards, the system integrates Class C (8/20μs, nominal 20kA, maximum 40kA) MOV-based AC surge protection and robust DC filter suppression. It operates reliably within ambient temperatures ranging from -40°C to +65°C (with automatic thermal derating above 45°C), features conformal-coated PCBs resistant to moisture/dust, complies with NEBS/ETSI seismic criteria, and meets EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission) standards.

Content updated: 2026-09-12T17:05:15.395Z