# Vertiv Liebert XD High Heat Density Rack-Level Cooling System (10kW-30kW/rack)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-xd

Model: Liebert XD

The Liebert XD is an industrial-grade thermal and infrastructure solution engineered for high availability and continuous operation.

## What this product is

A field-proven data center thermal or structural system providing precise environmental control and durable physical equipment protection.

## What problem it solves

Eliminates hot spots, handles extreme thermal densities, reduces facility PUE, and protects servers from particulate contamination.

## Who and where it is for

Enterprise edge facilities, telecom cloud data centers, high-density AI compute clusters, and industrial automated server rooms.

## Core advantages

- Heavy-duty industrial grade components designed for 24/7/365 uninterrupted mission-critical operation
- Advanced airflow management delivering superior energy efficiency and lower total cost of ownership
- Multi-tier hardware safety protection with comprehensive factory-aligned diagnostic routines
- Full compatibility with modern DCIM and centralized network management platforms

## Applications

- Telecom Data Centers
- Edge Computing Enclosures
- High-Density AI Clusters
- Industrial Equipment Rooms

## Technical specifications

- Mounting Format & Structural Compatibility: 1950 × 600 × 900 mm
- Central Telemetry Protocol Support: Central Telemetry Protocol Support
- System Capacity / Load Rating: Single Rack Supports 10kW ~ 30kW High-Density Heat Rejection
- Operating Noise Acoustic Level: Operating Noise Acoustic Level dB(A)
- Ambient Temperature Operating Range: Ambient Temperature Operating Range °C
- Operating Power Input Standard: 380V 3-Phase / 220V 1-Phase Compatible
- Compressor & Fan Power Units: Water-Free Data Hall Phase-Change Refrigerant Cycle
- Refrigerant & Energy Saving Topology: Top / Ceiling Mounted with Zero Floor Space Requirement
- Airflow Volume & Precision Control: Modular Two-Phase Natural Pumped Refrigerant Cooling

## Frequently asked questions

### How do I choose the right Liebert XD for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert XD compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert XD?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert XD?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert XD?

Yes. RICEWIND supplies Liebert XD from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert XD?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert XD.

### How to troubleshoot high refrigerant pressure alarm on Liebert XD under peak thermal load?

Inspect outdoor condenser fins for dirt or debris obstruction, verify EC fan speed control signal reaches 10V full speed, and check that condenser airflow clearances meet manufacturer guidelines.

### What is the corrective procedure when Liebert XD triggers low suction pressure during seasonal transitions?

Check indoor air filter differential pressure, clean accumulated dust to restore nominal airflow, inspect filter drier pressure drop, and recalibrate electronic expansion valve (EEV) minimum opening steps.

### How to resolve telemetry polling timeouts and data packet loss between Liebert XD and third-party DCIM?

Ensure RS485 shielded twisted-pair is grounded at one end only, verify presence of 120-ohm termination resistors at both bus ends, and adjust DCIM polling intervals from 200ms to 1000ms to eliminate bus congestion.

### How to verify control restart logic if fans on Liebert XD fail to auto-recover following grid transients?

Access controller service menu, verify 'Auto Restart after Power Failure' is enabled, check 24VDC auxiliary control supply ripple, and ensure phase sequence relay staggered delay matches power recovery specs.