# Vertiv Liebert ITA2 6kVA Rackmount Online Double-Conversion UPS (6000VA/6000W)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-ita2-6kva

Model: Liebert ITA2 6kVA

Vertiv Liebert ITA2 6kVA is a high-performance rackmount online double-conversion UPS featuring unity power factor (PF=1.0, 6kW) and full digital DSP architecture.

## What this product is

Telecom-grade power infrastructure module designed for VERTIV power architecture.

## What problem it solves

Eliminates grid power anomalies and brownout hazards across mission-critical communication centers.

## Who and where it is for

Cellular wireless sites, optical broadband hubs, edge computing racks, and industrial private networks.

## Core advantages

- Unity Power Factor 1.0: 6kVA/6kW high power density matching modern high-load IT and telecom demands
- Ultra-Wide Input Voltage (100V-288V): Resilient against harsh grid fluctuations to minimize battery wear
- High-Efficiency Online Double Conversion: Up to 95.5% efficiency for maximized energy savings and power purity
- Flexible Rack/Tower Convertible Design: Ultra-compact 2U form factor for standard cabinets and edge sites

## Applications

- Telecom cellular base stations and central offices -48V DC backup battery strings
- Data center high-rate UPS battery banks delivering critical runtime for server loads
- Electric utility substations 110V/220V DC switchgear breaker trip and closing power
- Off-grid renewable solar/wind hybrid storage and industrial uninterruptible backup sites

## Technical specifications

- AC input voltage range: 100VAC ~ 288VAC single-phase
- Efficiency: ≥ 96.0%
- Monthly Self-Discharge Rate: \< 2% per month (at 20°C standard)
- Designed Float Service Life: 10 to 12 Years (at 25°C nominal)
- Case Flame Retardancy: Reinforced ABS Enclosure (UL94-V0)
- DC output voltage range: 220VDC (176V ~ 286V)
- Dimensions: 85 (2U) × 430 × 500 mm
- Terminal Tightening Torque: 10 to 12 N·m (M8 Silver-Plated Copper)
- Input power factor: 1.0 (Rated 6kVA / 6kW)
- Form Factor & Mounting: 19-Inch Rackmount

## Frequently asked questions

### How do I choose the right Liebert ITA2 6kVA for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert ITA2 6kVA compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Liebert ITA2 6kVA?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Liebert ITA2 6kVA?

Yes. RICEWIND supplies Liebert ITA2 6kVA from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert ITA2 6kVA?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Liebert ITA2 6kVA.

### Does RICEWIND ship Liebert ITA2 6kVA internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### What are the engineering specifications for rack compatibility, N+X paralleling, and DC battery bank configuration on the Liebert ITA2 6kVA?

The VERTIV-UPS-ITA2-6K features a 2U ultra-dense rack/tower convertible form factor (85 x 430 x 500 mm), compatible with standard 19-inch IT/telecom racks with depths of 600mm and above. The unit supports direct N+X parallel redundancy (up to 3+1 units) with autonomous digital load-sharing imbalance controlled below 5%. The internal DC bus architecture supports a flexible battery configuration (12 to 20 blocks of 12V VRLA or lithium batteries), allowing seamless cascading with Vertiv standard 2U/3U battery modules via hot-pluggable connectors for demanding runtime scaling.

### What environmental robustness and surge protection features are engineered into the Liebert ITA2 6kVA for harsh telecom and edge conditions?

Engineered for harsh deployments, the ITA2 6kVA operates across 0°C to 50°C (100% continuous load from 0°C to 40°C, and 90% load at 45°C) and supports high-altitude operations up to 3,000 meters without derating. All internal mission-critical printed circuit boards feature industrial-grade conformal coating conforming to C3 anti-corrosion/humidity/dust resistance standards. The unit integrates a ruggedized SPD surge protection circuit rated for 4kV/5kA (8/20μs) alongside an isolated airflow tunnel design, preventing conductive airborne particulates from settling onto high-voltage internal components.

### What are the OEM technical specifications and safety requirements for wiring, interfaces, and communications on the Liebert ITA2 lithium battery UPS?

According to the official Vertiv user manual: 1. Pre-wiring Safety: Before moving or rewiring the UPS, all input power sources must be disconnected and the UPS must be completely shut down; otherwise, hazardous voltage may still exist at the output terminals. 2. Qualification: Electrical installation and commissioning must be carried out by certified engineers from the manufacturer or authorized agents. 3. Standards Compliance: The unit complies with IEC/EN 62040-1 (general safety), IEC/EN 62040-2 (Class C2 EMC), IEC/EN 62040-3 (performance/testing), and EU Directives 2014/35/EU, 2014/30/EU, and 2011/65/EU. As a Category C2 UPS, additional installation measures may be required in residential environments to suppress RF interference. 4. Accessories: All wiring, interconnects, and communication interfaces must use manufacturer-specified accessories.