# Vertiv Liebert ITA2 (6kVA/6kW Industrial Rack/Tower Online Double-Conversion UPS)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-ita2-6kva-ups

Model: Liebert ITA2 6kVA UPS

The Vertiv Liebert ITA2 6kVA is an industrial-grade, high-frequency online double-conversion UPS featuring a unity power factor (PF=1.0, 6kW capacity), a 2U rack/tower convertible form factor, and ultra-wide utility grid adaptability, engineered to deliver continuous, zero-transfer clean AC power to mission-critical telecom and industrial nodes.

## What this product is

A 2U DSP-controlled high-frequency double-conversion online uninterruptible power supply, equipped with IGBT rectification, flexible DC link topology, and convertible mounting mechanics for standard 19-inch racks or standalone towers.

## What problem it solves

Eliminates grid power anomalies including sags, surges, harmonics, and blackout risks, while resolving footprint constraints, rigid battery configuration limits, and severe thermal derating in harsh industrial installations.

## Who and where it is for

Edge computing micro-datacenters, industrial SCADA/PLC control automation, telecom BBU/RRU distribution shelters, healthcare imaging gear, and rail transit signaling rooms.

## Core advantages

- Unity Power Factor (PF=1.0): 6kVA delivers a full 6kW active power capacity, optimizing cabinet rack payload
- Ultra-wide input window (176V to 288V AC) slashes unnecessary battery cycle counts to preserve battery service life
- Multi-tap DC bus accommodates 16/20/24/32 battery blocks (±96V to ±192V DC), cutting replacement CAPEX
- Native 3+1 parallel multi-chassis scalability supports dynamic N+X redundancy and power expansion

## Applications

- Edge telecom hubs, optical transmission nodes, and remote microwave basestations
- Industrial manufacturing SCADA, DCS distribution racks, and assembly line controllers
- Hospital MRI/CT auxiliary power, laboratory analyzers, and medical clean systems
- Data center edge nodes and distributed enterprise networking distribution frames

## Technical specifications

- Rated output power: 6kVA / 6kW (Output Power Factor 1.0)
- Efficiency: ≥ 95.5%
- Maximum parallel capacity: Supports Up to 3+1 Parallel Redundancy
- Mounting format: 19-Inch Rackmount
- Rated battery voltage: ±96V / ±120V / ±144V / ±192V DC Flexible Config
- Input voltage range: 176V AC ~ 288V AC (Ultra-Wide AC Grid Tolerance)
- Operating Temperature Range: 0°C ~ +50°C (Robust Operating Range)
- UPS topology: Online Double-Conversion

## Frequently asked questions

### How do I choose the right Liebert ITA2 6kVA UPS for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert ITA2 6kVA UPS compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Liebert ITA2 6kVA UPS?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Liebert ITA2 6kVA UPS?

Yes. RICEWIND supplies Liebert ITA2 6kVA UPS from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert ITA2 6kVA UPS?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Liebert ITA2 6kVA UPS.

### Does RICEWIND ship Liebert ITA2 6kVA UPS internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### How does the ITA2 6kVA perform under environmental extremes, lightning, and voltage surges?

Compliant with IEC/EN 62040-2 standards, the unit incorporates Class D surge protective components capable of absorbing substantial differential and common-mode transients. Its circuit assemblies are fortified with industrial-grade conformal coating to resist dust and moisture. The unit functions reliably within an operating temperature window of 0°C to +50°C, sustaining zero derating up to +40°C.

### What parallel configuration and communication protocols are natively supported?

The ITA2 6kVA supports up to 3+1 (4 units total) parallel multi-frame redundancy using dedicated high-speed inter-chassis bus cables for precise load sharing. Supervisory communication ports include integrated RS485, USB, programmable dry-contacts, and an Intellislot card bay supporting SNMPv3, Modbus RTU, and Modbus TCP for DCIM integration.

### What is the wiring terminal pinout, DC cold start function, and emergency shut-off configuration?

The rear panel features high-durability terminal block interfaces for L, N, and PE inputs/outputs, alongside center-tapped battery connections (BAT+, BAT-, N). It incorporates dedicated DC Cold Start circuitry, enabling cold black-start operations directly from connected battery banks. Auxiliary dry-contact headers include Remote Emergency Power Off (REPO), generator signal inputs, and summary fault relays.