# Vertiv Liebert ITA-BCI0020k02 Rack/Tower External Battery Cabinet (3U)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-ita-bci0020k02

Model: Liebert ITA-BCI0020k02

The Vertiv Liebert ITA-BCI0020k02 is a 3U rack/tower convertible high-density external battery cabinet engineered specifically for Liebert ITA2 5kVA~20kVA UPS systems, equipped with heavy-duty quick-connect Anderson power connectors.

## What this product is

Standard 19-inch 3U rack/tower extended battery enclosure for ITA2 UPS.

## What problem it solves

Eliminates messy open battery banks in IT server rooms by integrating high-rate maintenance-free batteries in a matching 3U plug-and-play rack chassis.

## Who and where it is for

Liebert ITA2 5kVA, 6kVA, 10kVA, 16kVA, and 20kVA online double-conversion UPS systems.

## Core advantages

- Form factor matches ITA2 UPS for seamless rack or tower aesthetic consistency
- Heavy-duty keyed Anderson connectors guarantee safe, rapid deployment without cabling errors
- Scalable parallel architecture supports multiple battery banks for extended outage runtimes
- Integrated DC circuit breaker protection ensures total operational safety

## Applications

- Telecom cellular base stations and central offices -48V DC backup battery strings
- Data center high-rate UPS battery banks delivering critical runtime for server loads
- Electric utility substations 110V/220V DC switchgear breaker trip and closing power
- Off-grid renewable solar/wind hybrid storage and industrial uninterruptible backup sites

## Technical specifications

- Apparent Power: ITA/ITA2 10kVA/16kVA/20kVA systems VA
- Active Power: DC bus rated to support ±120V / ±144V / ±192V DC W
- Mounting format: 19-Inch Rackmount
- Monthly Self-Discharge Rate: \< 2% per month (at 20°C standard)
- Designed Float Service Life: 10 to 12 Years (at 25°C nominal)
- Case Flame Retardancy: Reinforced ABS Enclosure (UL94-V0)
- Terminal Tightening Torque: 10 to 12 N·m (M8 Silver-Plated Copper)
- Operating Temperature Range: -0 ~ +40°C
- Input power factor: 16~20 Cells Battery Bank
- Dimensions: 130 × 435 × 650 mm

## Frequently asked questions

### How do I choose the right Liebert ITA-BCI0020k02 for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert ITA-BCI0020k02 compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Liebert ITA-BCI0020k02?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Liebert ITA-BCI0020k02?

Yes. RICEWIND supplies Liebert ITA-BCI0020k02 from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert ITA-BCI0020k02?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Liebert ITA-BCI0020k02.

### Does RICEWIND ship Liebert ITA-BCI0020k02 internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### What are the wiring safety, electrical operation specifications, and compliance standards for the Vertiv Liebert ITA-BCI0020k02 lithium battery module when connected to the ITA2 1kVA~3kVA UPS?

According to the Liebert ITA2 LIO 1kVA~3kVA UPS User Manual, the wiring and installation of the ITA-BCI0020k02 lithium battery module and host system must adhere to the following mandatory specifications: 1. Personnel Qualifications: Installation and commissioning must be performed exclusively by Vertiv or authorized service engineers. Battery modules must never be disposed of in fire due to explosion hazards, and the system must not be used for life-support equipment. 2. Isolation and Rewiring: Before moving the unit or performing any rewiring, all AC inputs must be completely disconnected and the UPS must be entirely powered off, as hazardous voltages may remain present on output and DC terminals. 3. Compliance and Standards: The system complies with 2014/35/EU (LVD), 2014/30/EU (EMC), and 2011/65/EU (RoHS) directives, satisfying IEC/EN 62040-1 (safety), IEC/EN 62040-2 (Class C2 UPS, which may require additional RF suppression in residential environments), and IEC/EN 62040-3. All cabling and connections must utilize factory-specified accessories.

### What are the DC bus configurations and electrical specifications of the Vertiv Liebert ITA-BCI0020k02 battery pack?

The Vertiv Liebert ITA-BCI0020k02 (SKU: VERTIV-BAT-ITA-BCI0020K02) is a 3U high-density battery module engineered for Liebert ITA/ITA2 10kVA, 16kVA, and 20kVA UPS systems. Featuring a symmetrical split-bus DC topology, it supports 16 to 20 configurable VRLA battery blocks per string, corresponding to rated ±120Vdc, ±144Vdc, and ±192Vdc bus voltages. Designed to deliver high-rate discharge capacity at full 20kVA (PF=1.0) load, the module incorporates heavy-duty Anderson quick-connect polarized terminals, minimizing contact impedance and ensuring bus voltage drop under 1% during high-current draw.

### How does the ITA-BCI0020k02 withstand harsh operational environments, and what are its safety protection designs?

The ITA-BCI0020k02 operates between 0°C and +40°C (recommended 20°C–25°C for optimal 5-year float service life) with an IP20-rated reinforced galvanized steel chassis. Internal battery compartments utilize flame-retardant barriers meeting UL 94-V0 standards. Integrated multi-pole DC breakers deliver short-circuit, overcurrent, and reverse-polarity protection. Designed for passive thermal convection and seismic resilience, it passes 500Vdc insulation resistance testing (\>10MΩ), making it robust against high-humidity edge data center and telecom environment stresses.