# Vertiv Liebert GXT5 16kVA High-Capacity Rackmount Online UPS (16kVA/16kW 9U PF 1.0)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-gxt5-16kva

Model: Liebert GXT5 16kVA

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What this product is

High-reliability online double-conversion high-frequency Uninterruptible Power Supply (UPS) delivering zero-millisecond pure sine wave power to critical IT loads.

## What problem it solves

Delivers large-scale rackmount backup power up to 16kW within standard 19-inch IT enclosures without requiring external floor-mounted cabinet units.

## Who and where it is for

High-performance computing (HPC) server racks, enterprise IT rows, broadcast production hubs, and telecom core transmission racks.

## Core advantages

- True online double-conversion topology providing 0ms transfer time to isolate mains surges, sags, and harmonic distortions
- High output power factor (PF up to 0.9-1.0) delivering maximum active power capacity for high-density IT server loads
- Dual DSP digital processor control achieving over 95% operating efficiency and up to 99% in ECO mode
- Intelligent battery management featuring automated boost/float switching and scheduled self-test routines

## Applications

- Enterprise and cloud data center core networking suites, server clusters, and SAN storage arrays
- Financial banking transactions, securities clearing systems, and trading floor mission-critical IT
- Healthcare medical imaging suites (MRI, CT scanners) and critical intensive care instrumentation
- Industrial automation production lines, robotic workcells, and supervisory PLC control systems

## Technical specifications

- Apparent Power: 16000 VA
- Active Power: 16000 W
- Mounting format: 19-Inch Rackmount
- Power Conversion Efficiency:  95%
- Operating Temperature Range: 0°C to +40°C
- Input power factor: 1.0 (Ultra-High Power Factor)
- UPS topology: Online double-conversion, high-frequency pure sine wave
- Output voltage: 220/230/240 VAC (single-phase adjustable)
- Input voltage range: 176 ~ 288 VAC (full-load single-phase/three-phase compatible)
- Dimensions: 430 × 400 × 750 mm (main unit + bypass module)

## Frequently asked questions

### How do I choose the right Liebert GXT5 16kVA for my site?

Consider capacity, site power, environment and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert GXT5 16kVA compatible with my existing equipment?

Compatibility depends on your electrical infrastructure and connected devices. Our engineers can review your setup and confirm interfaces and integration before you order.

### What warranty and after-sales support are available for Liebert GXT5 16kVA?

Warranty follows the manufacturer policy for your region, and RICEWIND provides technical documentation and engineer-level support throughout the project.

### Does RICEWIND supply Liebert GXT5 16kVA?

Yes. RICEWIND supplies Liebert GXT5 16kVA from verified stock, MOQ from 1 piece; in-stock items dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert GXT5 16kVA?

RICEWIND maintains a cross-reference chart covering Huawei, Vertiv (Emerson), Eltek, ZTE and Delta modules. Contact us for the direct equivalent of Liebert GXT5 16kVA.

### Does RICEWIND ship Liebert GXT5 16kVA internationally?

Yes. RICEWIND ships worldwide and freight options depend on destination, weight and urgency. Contact us for a shipping quote to your location.

### How does the GXT5 16kVA 9U architecture achieve rack integration, maintenance bypass, and scalable battery runtime?

The GXT5-16KIRT9UXLE features a 9U rack/tower convertible architecture comprised of a 4U power module (rectifier/inverter) coupled with a 5U external battery cabinet (EBC, running on a 192VDC/384VDC DC bus), engineered for standard 19-inch deep IT racks. It incorporates a detachable Power Output Distribution (POD) maintenance bypass module, allowing seamless manual bypass transfer for hot-swappable servicing without dropping downstream critical loads. For runtime scalability, the internal intelligent battery charger communicates with up to six daisy-chained 5U external battery cabinets. The firmware automatically detects connected battery packs and dynamically scales charging current while safeguarding cell equalization and shortening recharge cycles.

### What protective mechanisms and environmental tolerances are engineered into the GXT5 16kVA for harsh grid environments?

Engineered for demanding edge and industrial environments, the Vertiv GXT5 16kVA operates continuously from 0°C to 40°C without derating (up to 50°C with derating) and supports un-derated operation up to 3,000 meters altitude. Its electrical front-end complies with ANSI C62.41 and IEC 61000-4-5 surge and transient immunity standards. All critical internal printed circuit boards are treated with industrial-grade conformal coating to resist dust, humidity, and chemical contaminants. Thermal management is driven by PWM multi-stage variable-speed fans within an isolated front-to-back airflow channel. Furthermore, redundant DC dual-pole breakers and fast-acting fuses eliminate battery backfeed and protect against short-circuit thermal runaways.

### What are the electrical safety standards and interface operation requirements for Vertiv Liebert UPS during rewiring, moving, and commissioning?

According to the manufacturer manual specifications, electrical and interface operations must strictly comply with the following: 1. Before moving or rewiring the UPS, all input power must be disconnected and the UPS must be completely powered off, as hazardous voltage may still exist at the output terminals; 2. Installation and commissioning must be carried out strictly by Vertiv factory engineers or authorized certified partners; 3. Disposing of the battery in fire is strictly prohibited, and operation is prohibited in environments containing conductive dust, corrosive gases, salt spray, flammable gases, mechanical vibration, or strong electromagnetic interference; 4. Electrical implementation complies with IEC/EN 62040-1 (general safety), IEC/EN 62040-2 (Class C2 EMC), and IEC/EN 62040-3 standards, requiring factory-specified accessories for all terminations.

Content updated: 2026-09-12T05:36:28.023Z