# Vertiv Liebert GXT5 10kVA Online UPS 10 kVA/10 kW

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-gxt5-10kva

Model: Liebert GXT5 10kVA

Vertiv Liebert GXT5 10kVA is a single-phase online double-conversion UPS rated at 10000 VA/10000 W with pure sinewave output.

## What this product is

A single-phase 230 V online double-conversion UPS with pure sinewave output. The 10 kVA model carries parallel ports for parallel or redundant operation, and up to 10 external battery cabinets can be connected (six are auto-detected) to extend runtime.

## What problem it solves

Protects critical IT and infrastructure loads with continuous power conditioning, outage protection and scalable runtime.

## Who and where it is for

Critical-load supply in data equipment rooms; Backup power configuration in telecom equipment rooms; Power-continuity upgrades in enterprise equipment rooms.

## Core advantages

- Selectable output voltage: 200/208/220/230/240 VAC.
- Output power factor: 1.0.
- Output waveform: pure sinewave.
- Rated active output power: 10,000 W.

## Applications

- Edge Applications
- Finance and Banking
- Telecom
- Healthcare
- Retail
- Cloud Edge

## Technical specifications

- Rated capacity: 10,000 VA / 10,000 W
- Input frequency range: 40-70 Hz without battery operation
- Efficiency: 95 % in online double-conversion; up to 98 % in Active ECO
- Selectable output voltage: 200/208/220/230/240 VAC
- Maximum permitted input voltage: 288 VAC
- Output power factor: 1.0
- Output waveform: Pure sinewave
- Output frequency: 50/60 Hz
- Default charging current: 2.25 A default; 8 A maximum
- Storage temperature range: -15 - +40 °C
- Operating altitude: Up to 3000 m; no derating at 25 °C
- Bypass voltage upper limit settings: +10%, +15%, +20%
- Default bypass voltage upper limit: +10%
- Bypass voltage lower limit settings: -10%, -15%, -20%
- Default bypass voltage lower limit: -15%
- Relative humidity: 0-95%
- Noise sound pressure level: \<55 dBA
- UPS topology: Online double conversion
- Phase configuration: Single phase
- Maximum external battery cabinet quantity: Up to 10 (six auto-detected)
- Dimensions (W×D×H): 430×630×217 mm
- Mounting method: Rack/tower
- POD module model: PD5-CE10HDWRMBS
- Product model: GXT5-10KIRT5UXLN
- Compatible external battery cabinet model: GXT5-EBC192VRT3U
- Input voltage range: 176-288 VAC; 100-176 VAC with derating
- Internal battery: Valve-regulated lead-acid, 2 × 8 × 12 V × 9.0 Ah (16 blocks)
- Runtime at full load: 2 minutes at full load (10 kVA)
- Runtime at half load: 7 minutes at half load (10 kVA)
- Overload capability: \>150 % for at least 200 ms; 125-150 % 60 s; 105-125 % 5 min; ≤105 % continuous
- Output connection: Output terminal block
- Weight: 74.5 kg
- Operating temperature: Full power up to 40 °C; up to 50 °C with derating
- Safety standards: UL 1778, C-UL listed; IEC 62040-1:2017; EN 62040-1:2008+A1:2013
- EMC standards: IEC/EN/AS 62040-2 (Cat 2); FCC Part 15 Class A; CISPR22 Class A

## Frequently asked questions

### What are the rated capacity and power of Vertiv Liebert GXT5 10kVA?

The rating is 10000 VA and 10000 W.

### What input voltage range and derating condition apply to Vertiv Liebert GXT5 10kVA?

Without battery operation it accepts 176-288 VAC; 100-176 VAC requires derating.

### What efficiency and output waveform does Vertiv Liebert GXT5 10kVA provide?

Online efficiency is up to 95%, Active ECO up to 98%, with pure sinewave output.

### What internal battery and runtime does Vertiv Liebert GXT5 10kVA have?

It uses valve-regulated, non-spillable lead acid batteries; runtime is about 2 minutes at full load and 7 minutes at half load.

### What expansion and applications are supported by Vertiv Liebert GXT5 10kVA?

It supports parallel or redundant operation and external battery cabinets; listed applications are edge, finance and banking, telecom, healthcare, retail and cloud edge.

Content updated: 2026-09-12T05:34:46.364Z