# Vertiv Liebert DME12 Small Room Precision Air Conditioner (12.5kW Cooling)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-dme12

Model: Liebert DME12

The Vertiv Liebert DME12 is a mission-critical small room precision air conditioning indoor system delivering 12.5kW total cooling with an ultra-high sensible heat ratio for 24/7 computer rooms.

## What this product is

Precision environmental control unit engineered specifically for server rooms, network closets, and edge telecom shelters.

## What problem it solves

Eliminates hot spots on server racks and prevents static discharge by maintaining steady temperature and humidity around the clock.

## Who and where it is for

Medium and small IT server rooms, telecom shelters, and industrial automation control centers.

## Core advantages

- Sensible heat ratio over 90% avoids over-dehumidification
- High-reliability industrial scroll compressor for continuous duty
- Intelligent digital display with Modbus remote monitoring
- High CFM airflow effectively eliminates rack hot spots

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Cooling capacity: 12.5 kW
- Fan Control Type: Multi-Speed Direct Drive Centrifugal Fan
- Sensible Heat Ratio (SHF): \> 0.90
- Main power supply: 380V 3-Phase / 220V 1-Phase Compatible
- Airflow Volume: 3300 m³/h
- Total Weight: 145 kg
- Refrigerant: R410A Eco Refrigerant
- Dimensions: 1750 × 600 × 500 mm

## Frequently asked questions

### How do I choose the right Liebert DME12 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DME12 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DME12?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DME12?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DME12?

Yes. RICEWIND supplies Liebert DME12 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DME12?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DME12.

### What are the core cooling and electrical specifications of the Vertiv Liebert DME12 (VERTIV-AC-DME12)?

The Vertiv Liebert DME12 indoor precision air conditioner delivers a rated sensible/total cooling capacity of 12.5 kW using eco-friendly R410A refrigerant. Engineered with a Sensible Heat Ratio (SHF) exceeding 0.90 and an airflow volume of 3300 m³/h, it maximizes sensible heat removal while avoiding parasitic latent cooling. The unit operates on a 380VAC ± 10% (3-phase 5-wire, 50Hz) power input, measures 1750 × 600 × 500 mm (footprint of just 0.3 m²), and weighs 145 kg, providing compact, high-efficiency cooling for edge data centers and server rooms.

### How does the Liebert DME12 support multi-unit networking, monitoring compatibility, and capacity expansion?

The DME12 integrates a microcomputer control architecture equipped with an RS-485 port supporting standard Modbus-RTU, with optional network cards for SNMP and Web-based DCIM integration. For expansion and redundancy, up to 32 units can be team-networked via CAN/RS-485 bus, supporting automatic lead-lag rotation, anti-competitive operation logic (preventing concurrent heating/cooling conflicts), and dynamic cascading during fault conditions. This allows seamless interoperation alongside legacy Liebert DataMate3000 series systems.

### What engineering design features ensure the DME12's wide-temperature resilience and 24/7 continuous industrial reliability?

Designed for 365 days × 24 hours continuous operation, the DME12 pairs with standard outdoor air-cooled condensers to operate reliably across ambient outdoor temperatures from -15°C to +45°C, expandable to -34°C with the low-ambient kit. Internally, it features high-efficiency scroll compressors, direct-drive centrifugal/EC blower fans with thermal overload cutouts, dual high/low refrigerant pressure switches, and an IP20 isolated electrical control box with surge suppressors to withstand voltage spikes and grid instabilities.

Content updated: 2026-09-11T17:17:27.083Z