Model: Liebert DME07

The Vertiv Liebert DME07 is an ultra-compact room precision air conditioning indoor unit occupying under 0.45 m² while delivering 7.5kW of dependable heat removal for edge mission-critical racks.

## What this product is

Small-footprint precision cooling indoor unit engineered for edge data closets and telecommunication shelters.

## What problem it solves

Solves thermal management in ultra-dense or tight physical environments without sacrificing industrial durability.

## Who and where it is for

Edge micro-datacenters, mobile base station shelters, and wiring equipment rooms.

## Core advantages

- Ultra-compact footprint under 0.45 m²
- Automatic power-loss recovery and restart
- High sensible heat ratio protects sensitive electronic components
- Quiet acoustic operation and low lifecycle TCO

## Applications

- Hyperscale and enterprise cloud data center high-density server halls and aisle containment
- Telecommunications switching centers, optical transmission rooms, and carrier core facilities
- High-reliability industrial test laboratories and clean room production environments
- Rail transit command signaling centers and electrical power grid dispatch operations

## Technical specifications

- Fan Control Type: Multi-Speed Direct Drive Centrifugal Fan
- Cooling capacity: 7.5 kW
- Sensible Heat Ratio (SHF): ≥ 0.90 (High SHF)
- Main power supply: 380V 3-Phase / 220V 1-Phase Compatible
- Airflow Volume: 2200 m³/h
- Total Weight: 110 kg
- Refrigerant: R410A Eco Refrigerant
- Dimensions: 1750 × 510 × 385 mm

## Frequently asked questions

### How do I choose the right Liebert DME07 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DME07 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DME07?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DME07?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DME07?

Yes. RICEWIND supplies Liebert DME07 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DME07?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DME07.

### What are the core thermal and electrical specifications of the Vertiv Liebert DME07 precision air conditioning unit?

The Vertiv Liebert DME07 (SKU: VERTIV-AC-DME07) delivers a rated total cooling capacity of 7.5 kW with a high Sensible Heat Ratio (SHF) exceeding 0.90 and a nominal airflow of 2,200 m³/h utilizing R410A refrigerant. Designed for compact footprints (\<0.45 m², dimensions 1750 × 510 × 385 mm, weight 110 kg), it supports either 220VAC 1-phase or 380VAC 3-phase 50Hz electrical feeds. The high sensible heat ratio configuration prioritizes sensible equipment heat dissipation while preventing unnecessary latent dehumidification, optimizing system EER in telecom edge shelters.

### What are the compatibility options for Liebert DME07 regarding outdoor condensers, teamwork networking, and DCIM monitoring?

The DME07 indoor unit seamlessly pairs with Vertiv proprietary air-cooled outdoor condensers, supporting long equivalent piping lengths and high vertical drops. It features an onboard RS485 communication interface natively running Modbus-RTU protocols for direct DCIM integration. The unit supports multi-unit teamwork networking, providing automatic duty/standby rotation, cascade cooling on peak loads, failure takeover redundancy, and anti-competitive operation prevention, enabling zero-downtime scalability for mission-critical edge sites.

### What are the technical and electrical requirements for moving, rewiring, and safety compliance of the Liebert ITA2 1kVA~3kVA lithium UPS system?

According to the user manual safety regulations: 1. Moving and Rewiring Requirements: All input power sources must be disconnected and the UPS must be completely shut down prior to moving or rewiring; otherwise, hazardous voltages may still be present at the output terminals. 2. Professional Qualifications and Liability: Installation and commissioning must be conducted by professional engineers from the manufacturer or authorized distributors; damages resulting from unauthorized operations are excluded from warranty coverage. 3. Compliance Standards: Electrical installation must comply with 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU (RoHS), and IEC/EN 62040-1, IEC/EN 62040-2 (Class C2), IEC/EN 62040-3 standards using manufacturer-specified accessories. Residential deployment may require additional suppression measures for radio frequency interference.

Content updated: 2026-09-11T17:18:30.719Z