# Vertiv Liebert DataMate3000 DME07 7.5kW Precision Air Conditioner (7.5kW)

RICEWIND · Vertiv

https://ricewind.com/en/products/liebert-datamate3000-dme07

Model: Liebert DataMate3000 DME07

The Vertiv Liebert DataMate3000 DME07 is an enterprise-grade 7.5kW vertical precision air conditioning unit engineered specifically for continuous 24/7/365 thermal management in micro edge data centers, telecommunication base stations, and electrical substation control rooms, featuring high sensible heat ratio (SHF ≥ 0.90) refrigeration, scroll compression, and native RS-485 Modbus remote telemetry integration.

## What this product is

The DME07 is a compact direct-expansion (DX) air-cooled precision environmental control unit comprising an indoor floor-standing fan coil cabinet and an outdoor condenser. It integrates a hermetic scroll compressor, hydrophilic aluminum fin evaporator, high static pressure centrifugal blower, and an advanced microcomputer control terminal to extract sensible heat loads continuously without excessive dehumidification.

## What problem it solves

Replaces standard comfort air conditioners that suffer from inadequate sensible heat capacity, excessive over-drying (triggering electrostatic hazards), frequent cycling failures, and lack of industrial monitoring interfaces, eliminating hot spots in high-density IT and telecom enclosures.

## Who and where it is for

Telecom shelter cabins, 4G/5G mobile aggregation hubs, power substation automation rooms, enterprise wiring closets (IDF/MDF), railway trackside equipment shelters, and containerized modular edge data centers.

## Core advantages

- Ultra-high Sensible Heat Ratio (SHF ≥ 0.90) focuses cooling capacity on dry electronic heat dissipation without wasting energy on room dehumidification.
- Industrial-grade scroll compressor and heavy-duty direct-drive blower ensure 8,760 hours of continuous, trouble-free annual operation.
- Native RS485 communication bus supporting Modbus-RTU protocol for transparent integration into telecom site supervision and SCADA/BMS systems.
- Compact vertical design with front-access maintenance allows snug installation against walls and corners in space-restricted technical rooms.

## Applications

- Telecom 4G/5G wireless transceiver base transceiver stations (BTS)
- Electric utility relay and SCADA automation control rooms
- Enterprise server rack enclosures and structured cabling distributor rooms
- Railway signaling, wayside interlocking, and communication cabins

## Technical specifications

- Cooling capacity: 7.5 kW Rated Cooling Capacity
- Airflow Delivery & Fan Type: Upflow / Front Flow (High Airflow Small Enthalpy Design)
- Sensible Heat Ratio (SHF): ≥ 0.90 (High SHF)
- Compressor type: High-Efficiency Flexible Scroll Compressor
- Control System & HMI: Large Screen Microprocessor Controller
- Refrigerant: R410A Eco-Friendly Refrigerant
- Communication interfaces: RS485 Communication Port, Supports Modbus Protocol
- Dimensions: Compact Floor-Standing Design (Small Footprint) mm

## Frequently asked questions

### How do I choose the right Liebert DataMate3000 DME07 for my site?

Consider total sensible heat load, airflow configuration (upflow/downflow), ambient temperature limits, piping elevation and monitoring needs. Share your requirements with RICEWIND and we will compare suitable models from multiple brands for you.

### Is Liebert DataMate3000 DME07 compatible with my existing infrastructure?

Compatibility depends on power supply, refrigerant pipe dimensions and environmental monitoring protocols (RS-485/Modbus/SNMP). Our engineers can verify pipe sizing, wiring and BMS integration before you order.

### Does RICEWIND provide international shipping for Liebert DataMate3000 DME07?

Yes. Indoor and outdoor units are shipped globally with reinforced non-coniferous export wooden crates and nitrogen holding pressure. Freight options depend on destination port and urgency — contact us for a shipping quote.

### What warranty and technical support are available for Liebert DataMate3000 DME07?

Warranty follows the manufacturer policy for your region. RICEWIND provides installation drawings, commissioning documentation, OEM spare parts and engineer-level technical assistance throughout the project.

### Does RICEWIND supply Liebert DataMate3000 DME07?

Yes. RICEWIND supplies Liebert DataMate3000 DME07 from verified inventory, MOQ from 1 unit; in-stock units dispatch within 24-48 hours with worldwide shipping.

### Is there a cross-reference or equivalent for Liebert DataMate3000 DME07?

RICEWIND maintains a cross-reference database covering Vertiv (Liebert), Envicool, and Huawei thermal management systems. Contact us for direct equivalents or retrofit recommendations for Liebert DataMate3000 DME07.

### What are the nominal cooling capacity, efficiency, and Sensible Heat Ratio (SHF) specifications of the Vertiv DME07?

Under standard rating conditions (indoor dry bulb 24°C, 50% RH), the DME07 delivers 7.5 kW nominal total cooling capacity with a Sensible Heat Ratio (SHF) equal to or exceeding 0.90 (delivering ≥6.75 kW sensible cooling). Operating on a high volumetric airflow (~2,200 to 2,600 m³/h) and low enthalpy differential design, the system keeps coil surface temperatures above dew point to maximize refrigeration EER (exceeding 3.0) and prevent unnecessary dehumidification energy loss.

### How does the DME07 execute master/standby rotation and BMS network telemetry?

The integrated microcomputer controller supports built-in self-contained teamwork clustering. By connecting dedicated two-wire interconnect links between adjacent units, it facilitates programmable duty/standby auto-rotation (balancing compressor runtimes), automatic hot-standby failover upon primary unit fault, and dual-unit concurrent run during high-temperature alarms. For facility management, an onboard RS-485 port exposes standard Modbus-RTU registers for reading room temp/humidity, blower status, component runtime, and detailed fault codes.

### What are the environmental tolerance and electrical protection parameters for extreme operating conditions?

Paired with standard outdoor air-cooled condensers, the system operates across outdoor ambient envelopes of -15°C to +45°C, with optional low-ambient wind-speed control kits extending operation down to -34°C for arctic installations. The electrical control assembly accommodates wide grid voltage fluctuations (nominal ±10% to ±15%) and incorporates transient surge suppression in compliance with IEEE C62.41 standards to withstand switching spikes and lightning coupling.

Content updated: 2026-09-12T16:52:21.959Z